Loss of the Captain Right STAT Output Discrete from the PHC 1
TASK 30-31-00-810-875-A
Loss of the Captain Right STAT Output Discrete from the PHC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-710-189-A 4. Fault Isolation
Subtask 30-31-00-810-130-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:39 UTC
Loss of the Captain Right STAT Output Discrete from the PHC 1
1. Possible Causes
- ADIRU-1 [1FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 343102 |
Subtask 30-31-00-710-189-A 4. Fault Isolation
Subtask 30-31-00-810-130-A
A. If the test confirms the fault:
(1) Disconnect electrical connector A from PHC1 and remove ADIRU1.
(2) Do a check of the wiring between ASM 343102 pin A/X of PHC1 and pin AA/4G of ADIRU1.
(a) If there is no continuity:
1 Repair the wiring.
2 Connect electrical connector A to PHC1.
3 Install ADIRU1.
(b) If there is continuity:
1 Replace ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
Subtask 30-31-00-710-199-A (1) Disconnect electrical connector A from PHC1 and remove ADIRU1.
(2) Do a check of the wiring between ASM 343102 pin A/X of PHC1 and pin AA/4G of ADIRU1.
(a) If there is no continuity:
1 Repair the wiring.
2 Connect electrical connector A to PHC1.
3 Install ADIRU1.
(b) If there is continuity:
1 Replace ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.