W DOC AIRBUS | TSM A320F

Failure of the L Static Probe (PHC 3)


TASK 30-31-00-810-827-A
Failure of the L Static Probe (PHC 3)


1. Possible Causes
  • PROBE-L STATIC, 3 [7DA3]
  • PHC-3 [6DA3]
  • wiring from the PHC 3 (6DA3) to the L static probe 3 (7DA3)
  • wiring
  • ADIRU-3 [1FP3]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 303103
AMM 30-31-34-000-002
Removal of the Probe Heat Computer (PHC)
AMM 30-31-34-400-002
Installation of the Probe Heat Computer (PHC)
AMM 34-11-16-000-001
Removal of the Static Probe
AMM 34-11-16-400-002
Installation of the Static Probe
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341302
3. Fault Confirmation
Subtask 30-31-00-710-102-A
A. Test
   (1) Do the operational test of the probe ice protection AMM 30-31-00-710-001.
4. Fault Isolation
Subtask 30-31-00-810-076-A
A. If the test gives the maintenance message L STATIC PROBE 7DA3:
  • do a check of the resistance between pin 2 and pin 1.
   (1) If the resistance is more than 13 ohms (open circuit) or less than 10 ohms (short circuit).
     (a) Replace the PROBE-L STATIC, 3 [7DA3] , AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
   (2) If the resistance is between 10 ohms and 13 ohms:
     (a) Replace the PHC-3 [6DA3] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
     (b) If the fault continues:
  • do a check and repair the wiring from the PHC 3 (6DA3) to the L static probe 3 (7DA3) pin A/D to pin 2 ASM 303103.
   (3) If the fault continues:
     (a) Disconnect connector A from PHC 3 and remove ADIRU 3 AMM 34-12-34-000-001.
     (b) Do a check of the probe signal wiring ASM 341302 between PHC 3 pin A/X and ADIRU 3 pin AA/4G.
       1 If there is no continuity:
       2 If there is continuity:
Subtask 30-31-00-710-103-A
B. Do the operational test given in Para. 3.