Failure of the L Static Probe (PHC1)
TASK 30-31-00-810-805-A
Failure of the L Static Probe (PHC1)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-710-058-A 4. Fault Isolation
Subtask 30-31-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:34 UTC
Failure of the L Static Probe (PHC1)
1. Possible Causes
- PROBE-L STATIC, 1 [7DA1]
- PHC-1 [6DA1]
wiring from the PHC 1 (6DA1) to the L static probe 1 (7DA1) - wiring
- ADIRU-1 [1FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| ASM 303101 | |
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 34-11-16-000-001 | Removal of the Static Probe |
| AMM 34-11-16-400-002 | Installation of the Static Probe |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341302 |
Subtask 30-31-00-710-058-A 4. Fault Isolation
Subtask 30-31-00-810-054-A
A. If the test gives the maintenance message L STATIC PROBE 7DA1:
(a) Replace the PROBE-L STATIC, 1 [7DA1] , AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
(2) If the resistance is between 10 ohms and 13 ohms:
(a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
(a) Disconnect connector A from PHC 1 and remove ADIRU 1 AMM 34-12-34-000-001.
(b) Do a check of the probe signal wiring ASM 341302 between PHC 1 pin A/Y and ADIRU 1 pin AA/4H.
1 If there is no continuity:
Subtask 30-31-00-710-059-A - do a check of the resistance between pin 2 and pin 1.
(a) Replace the PROBE-L STATIC, 1 [7DA1] , AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
(2) If the resistance is between 10 ohms and 13 ohms:
(a) Replace the PHC-1 [6DA1] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
- do a check and repair the
wiring from the PHC 1 (6DA1) to the L static probe 1 (7DA1) , pin A/D to pin 2 ASM 303101.
(a) Disconnect connector A from PHC 1 and remove ADIRU 1 AMM 34-12-34-000-001.
(b) Do a check of the probe signal wiring ASM 341302 between PHC 1 pin A/Y and ADIRU 1 pin AA/4H.
1 If there is no continuity:
- Repair the wiring and
- Install ADIRU 1 AMM 34-12-34-400-001.
- Replace ADIRU-1 [1FP1] AMM 34-12-34-400-001.
B. Do the operational test given in Para. 3.