Loss of the Standby AOA Output Discrete from the PHC 3


TASK 30-31-00-810-882-A
Loss of the Standby AOA Output Discrete from the PHC 3


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
3. Fault Confirmation
Subtask 30-31-00-710-196-A
A. Do the operational test of the probe ice protection of the PHC-3 AMM 30-31-00-710-001.
4. Fault Isolation
Subtask 30-31-00-810-137-A
A. If the test confirms the fault:
   (1) Disconnect electrical connector A from PHC-3 and remove ADIRU-3.
   (2) Do a check of the wiring between ASM 341302 pin A/Z of PHC-3 and pin AA/3J of ADIRU-3.
     (a) If there is no continuity:
       1 Repair the wiring.
       2 Connect electrical connector A to PHC-3.
       3 Install ADIRU-3.
     (b) If there is continuity:
       1 Replace ADIRU-3 [1FP3] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
Subtask 30-31-00-710-206-A
B. Do the test given in Para. 3.