Loss of the PHC 3
TASK 30-31-00-810-823-A
Loss of the PHC 3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-710-094-A 4. Fault Isolation
Subtask 30-31-00-810-072-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:36 UTC
Loss of the PHC 3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 30-31-00-710-094-A 4. Fault Isolation
Subtask 30-31-00-810-072-A
A. If the test gives maintenance message PHC 6DA3:
(1) Replace PHC-3 [6DA3] AMM 30-31-34-000-002 AMM 30-31-34-400-002.
(a) If the fault continues:
(1) Replace PHC-3 [6DA3] AMM 30-31-34-000-002 AMM 30-31-34-400-002.
(a) If the fault continues:
- Replace ADIRU-3 [1FP3] AMM 34-12-34-000-001 AMM 34-12-34-400-001.