W DOC AIRBUS | TSM A320F

Failure of the PHC 2


TASK 30-31-00-810-863-A
Failure of the PHC 2


1. Possible Causes
  • PHC-2 [6DA2]
  • RELAY-OIL LOW PRESS AND GROUND, ENG 1 [10KS1]
  • RELAY-OIL LOW PRESS AND GROUND, ENG 2 [10KS2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 303102
AMM 30-31-34-000-002
Removal of the Probe Heat Computer (PHC)
AMM 30-31-34-400-002
Installation of the Probe Heat Computer (PHC)
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341302
3. Fault Confirmation
Subtask 30-31-00-860-053-A
A. Test
   (1) If the fault occurs at each engine start or each engine shutdown:
  • Go to Para 4.B.
   (2) If the fault occurs in other conditions:
  • Go to Para 4.A.
4. Fault Isolation
Subtask 30-31-00-810-115-A
A. Do the steps that follow:
Subtask 30-31-00-810-139-A
B. Do the steps that follow:
  • Remove ADIRU2 AMM 34-12-34-000-001.
  • Disconnect electrical connector A from PHC2.
  • Do a check of the wiring from:
  • PHC2 (6DA2) pin A/a to ADIRU2 (1FP2) pin AA/4F
  • PHC2 (6DA2) pin A/X to ADIRU2 (1FP2) pin AA/4G
  • PHC2 (6DA2) pin A/Y to ADIRU2 (1FP2) pin AA/4H
  • PHC2 (6DA2) pin A/Z to ADIRU2 (1FP2) pin AA/3J
  • PHC2 (6DA2) pin A/b to ADIRU2 (1FP2) pin AA/4J
    ASM 341302.
   (1) If the wiring is not correct:
   (2) If the wiring is correct:
     (a) If there is a ground signal:
     (b) If there is no ground signal:
  • Connect electrical connector A to PHC2.
  • Replace the RELAY-OIL LOW PRESS AND GROUND, ENG 1 [10KS1] and the RELAY-OIL LOW PRESS AND GROUND, ENG 2 [10KS2] .
       1 If the fault continues:
  • Disconnect electrical connector A from PHC2.
  • Do a check and repair the wiring from:
  • PHC2 (6DA2) pin A/f to engine 1 oil low pressure and ground relay (10KS1) pin A/6
  • Engine 1 oil low pressure and ground relay (10KS1) pin A/A to the ground
  • PHC2 (6DA2) pin A/g to engine 2 oil low pressure and ground relay (10KS2) pin A/6, and
  • Engine 2 oil low pressure and ground relay (10KS2) pin A/A to the ground
    ASM 303102.
  • Connect electrical connector A to PHC2.
[Rev.8 from Aug 2018] 2026.04.04 04:29:39 UTC