Loss of the L Static Probe Output-Discrete from the PHC 1


TASK 30-31-00-810-843-A
Loss of the L Static Probe Output-Discrete from the PHC 1


1. Possible Causes
  • PHC-1 [6DA1]
  • wiring from the PHC 1 (6DA1) to the ADIRU 1 (1FP1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 303101
AMM 30-31-34-000-002
Removal of the Probe Heat Computer (PHC)
AMM 30-31-34-400-002
Installation of the Probe Heat Computer (PHC)
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
ASM 341302
3. Fault Confirmation
Subtask 30-31-00-710-134-A
A. Test
   (1) Do the operational test of the probe ice protection AMM 30-31-00-710-001.
4. Fault Isolation
Subtask 30-31-00-810-092-A
A. If the test gives the maintenance message CHECK ADIRU 1 - L STATIC PHC 1 INTERFACE:
  • do a check for ground at pin A/X of the PHC 1 (6DA1) ASM 303101.
   (1) If there is no ground:
     (a) If the fault continues:
  • do a check and repair the wiring from the PHC 1 (6DA1) to the ADIRU 1 (1FP1), pin A/X to pin AA/4G ASM 341302.
     (b) If the fault continues:
  • do the INTERFACE TEST of the ADR (system 1) AMM 34-13-00-740-002
  • do the necessary corrective actions: (TSM chapter 34).
Subtask 30-31-00-710-135-A
B. Do the operational test given in Para. 3.