Loss of the TAT Sensor Output-Discrete from the PHC 1 to the ADIRU 3


TASK 30-31-00-810-855-A
Loss of the TAT Sensor Output-Discrete from the PHC 1 to the ADIRU 3


1. Possible Causes
  • PHC-1 [6DA1]
  • wiring from the PHC 1 (6DA1) to the ADIRU 3 (1FP3)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 34-13-00-810-911-A
Loss of the TAT Sensor 1 Input on the ADR3
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 303101
AMM 30-31-34-000-002
Removal of the Probe Heat Computer (PHC)
AMM 30-31-34-400-002
Installation of the Probe Heat Computer (PHC)
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
ASM 341302
3. Fault Confirmation
Subtask 30-31-00-710-158-A
A. Test
   (1) Do the operational test of the probe ice protection AMM 30-31-00-710-001.
4. Fault Isolation
Subtask 30-31-00-810-104-A
A. If the test gives the maintenance message CHECK ADIRU3 TAT PHC1 INTERFACE:
  • do a check for ground at pin A/<A of the PHC 1 (6DA1) ASM 303101.
   (1) If there is no ground:
     (a) If the fault continues:
  • do a check and repair the wiring from the PHC 1 (6DA1) to the ADIRU 3 (1FP3) pin A/<A to pin AA/4F ASM 341302.
     (b) If the fault continues:
Subtask 30-31-00-710-159-A
B. Do the operational test given in Para. 3.