Failure of the R Static Probe (PHC 3)
TASK 30-31-00-810-829-A
Failure of the R Static Probe (PHC 3)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-710-106-A 4. Fault Isolation
Subtask 30-31-00-810-078-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:36 UTC
Failure of the R Static Probe (PHC 3)
1. Possible Causes
- PROBE-R STATIC, 3 [8DA3]
- PHC-3 [6DA3]
wiring from the PHC 3 (6DA3) to the R static probe 3 (8DA3) - wiring
- ADIRU-3 [1FP3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| ASM 303103 | |
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 34-11-16-000-001 | Removal of the Static Probe |
| AMM 34-11-16-400-002 | Installation of the Static Probe |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341302 |
Subtask 30-31-00-710-106-A 4. Fault Isolation
Subtask 30-31-00-810-078-A
A. If the test gives the maintenance message R STATIC PROBE 8DA3:
(a) Replace the PROBE-R STATIC, 3 [8DA3] , AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
(2) If the resistance is between 10 ohms and 13 ohms:
(a) Replace the PHC-3 [6DA3] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
(a) Disconnect connector A from PHC 3 and remove ADIRU 3 AMM 34-12-34-000-001.
(b) Do a check of the probe signal wiring ASM 341302 between PHC 3 pin A/Y and ADIRU 3 pin AA/4H.
1 If there is no continuity:
Subtask 30-31-00-710-107-A - do a check of the resistance between pin 2 and pin 1.
(a) Replace the PROBE-R STATIC, 3 [8DA3] , AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
(2) If the resistance is between 10 ohms and 13 ohms:
(a) Replace the PHC-3 [6DA3] , AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
(b) If the fault continues:
- do a check and repair the
wiring from the PHC 3 (6DA3) to the R static probe 3 (8DA3) pin A/E to pin 2 ASM 303103.
(a) Disconnect connector A from PHC 3 and remove ADIRU 3 AMM 34-12-34-000-001.
(b) Do a check of the probe signal wiring ASM 341302 between PHC 3 pin A/Y and ADIRU 3 pin AA/4H.
1 If there is no continuity:
- Repair the wiring and
- Install ADIRU 3 AMM 34-12-34-400-001.
- Replace ADIRU-3 [1FP3] AMM 34-12-34-400-001.
B. Do the operational test given in Para. 3.