Loss of the Validation Input (PHC 3)
TASK 30-31-00-810-834-A
Loss of the Validation Input (PHC 3)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 30-31-00-710-116-A 4. Fault Isolation
Subtask 30-31-00-810-083-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:37 UTC
Loss of the Validation Input (PHC 3)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-00-710-001 | Operational Test of the Probe Ice Protection |
| ASM 303103 | |
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
Subtask 30-31-00-710-116-A 4. Fault Isolation
Subtask 30-31-00-810-083-A
A. If the test gives the maintenance message PHC3 : LGCIU2:
Subtask 30-31-00-710-117-A - do a check for ground at pin A/I of the PHC 3 (6DA3).
- replace the PHC-3 [6DA3] AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
- replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check and repair the wiring from the PHC 3 to the LGCIU 2 , pin A/<I to pin AA/12F ASM 303103.
B. Do the operational test given in Para. 3.