Cold Weather Maintenance - Auxiliary Power Unit
TASK 12-31-49-660-001-A
Cold Weather Maintenance - Auxiliary Power Unit
This procedure gives the cold weather maintenance practices for the Auxiliary Power Unit (APU) when the aircraft is in a cold soak condition.
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 12-31-49-860-050-A
Subtask 12-31-49-660-057-A
(a) If necessary, do an oil change to type 1.
Subtask 12-31-49-660-054-A
[Rev.10 from 2021]
2026.04.01 04:22:21 UTC
Cold Weather Maintenance - Auxiliary Power Unit
FIN: 4005KM
1. Reason for the JobThis procedure gives the cold weather maintenance practices for the Auxiliary Power Unit (APU) when the aircraft is in a cold soak condition.
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 315AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-31-24-660-001-A | Cold Weather Maintenance - Electrical Power |
| TASK 12-33-21-618-001-A | Pre-conditioning through the LP Ground Connection (Aircraft Electrical Power Available) |
| TASK 12-33-21-618-001-A-01 | Pre-conditioning through the HP Ground Connection |
| TASK 12-33-21-618-001-A-02 | Pre-conditioning with the APU |
| TASK 12-33-21-618-001-A-03 | Pre-conditioning through the LP Ground Connection (Aircraft Electrical Power Not Available) |
| TASK 49-00-00-860-005-A | APU Start by External Power |
| TASK 49-00-00-860-005-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-005-A | APU Start by External Power |
| TASK 49-00-00-860-005-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-006-A | APU Shutdown by External Power |
| TASK 49-00-00-860-006-A-01 | APU Shutdown by Batteries |
| TASK 49-00-00-860-008-A | APU Start by External Power |
| TASK 49-00-00-860-008-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-008-A | APU Start by External Power |
| TASK 49-00-00-860-008-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 49-61-34-000-002-A | Removal of the Electronic Control Box (ECB) (APS 3200) |
| TASK 49-61-34-000-003-A | Removal of the Electronic Control Box (ECB) (131-9(A)) |
| TASK 49-61-34-400-002-A | Installation of the Electronic Control Box (ECB) (APS 3200) |
| TASK 49-61-34-400-003-A | Installation of the Electronic Control Box (ECB) (131-9(A)) |
| TASK 49-90-00-600-005-A | Oil Change (Drain Procedure) (APS 3200) |
| TASK 49-90-00-600-005-A-01 | Oil Change (Top-Off Procedure) (APS 3200) |
| TASK 49-90-00-600-005-A-02 | Brand/Type Oil Change (Flush Procedure) (APS 3200) |
| TASK 49-90-00-600-008-A | Oil Change (Drain Procedure) (131-9(A)) |
| TASK 49-90-00-600-008-A-01 | Oil Change (Top-Off Procedure) (131-9(A)) |
| TASK 49-90-00-600-008-A-02 | Brand/Type Oil Change (Flush Procedure) (131-(A)) |
Subtask 12-31-49-860-050-A
A. Not Applicable
4. ProcedureSubtask 12-31-49-660-057-A
A. APU Air Intake
(2) Wait 5 minutes before second start if first start carried out before removing snow & ice. snow & ice.
Subtask 12-31-49-660-055-A NOTE: Ice and/or snow can form in the APU air intake and difficult the APU starting.
(1) If you can see snow or signs of ice on the APU air intake, do the de-icing of the aircraft before APU start. (2) Wait 5 minutes before second start if first start carried out before removing snow & ice. snow & ice.
B. Electronic Control Box 59KD (ECB 59KD)
(1) If the Outside Air Temperature (OAT) is/will be lower than -40 deg.C (-40.00 deg.F) and the aircraft is not pre-conditioned (heated) alternatively:
Subtask 12-31-49-660-056-A (1) If the Outside Air Temperature (OAT) is/will be lower than -40 deg.C (-40.00 deg.F) and the aircraft is not pre-conditioned (heated) alternatively:
- through the Low Pressure (LP) ground connection (Ref. AMM TASK 12-33-21-618-001),
- the High Pressure (HP) ground connection (Ref. AMM TASK 12-33-21-618-001), or
- with the APU (Ref. AMM TASK 12-33-21-618-001).
- If a GTCP 36-300 APU is installed
(Ref. AMM D/O 49-61-34-00) - If an APS 3200 APU is installed
(Ref. AMM TASK 49-61-34-000-002) - If a 131-9(A) APU is installed
(Ref. AMM TASK 49-61-34-000-003)
CAUTION:
USE ONLY APPROVED TYPES/BRANDS OF LUBRICANTS.
C. Auxiliary Power Unit (APU) NOTE: Do not mix oils of different brands or types.
NOTE: It is recommended to use type 1 for APU operation in cold weather conditions.
(1) Oil type. (a) If necessary, do an oil change to type 1.
- If a GTCP 36-300 APU is installed
(Ref. AMM D/O 49-90-00-60). - If an APS 3200 APU is installed
(Ref. AMM TASK 49-90-00-600-005). - If a 131-9(A) APU is installed
(Ref. AMM TASK 49-90-00-600-008).
NOTE: These values are only applicable if all the access doors are closed.
(a) It is recommended to start the APU every three hours and operate it for one hour if the Outside Air Temperature (OAT) is lower than -30 deg.C (-22.00 deg.F). - If a GTCP 36-300 APU is installed
(Ref. AMM TASK 49-00-00-860-003) - If an APS 3200 APU is installed
(Ref. AMM TASK 49-00-00-860-005) (Ref. AMM TASK 49-00-00-860-006) - If a 131-9(A) APU is installed
(Ref. AMM TASK 49-00-00-860-008) (Ref. AMM TASK 49-00-00-860-009)
D. APU Starting after a Cold Soak Condition
(1) ECB 59KD.
If the temperature of the ECB is lower than -40 deg.C (-40.00 deg.F), use a pre-conditioning procedure to increase the temperature of the ECB to a minimum of -40 deg.C (-40.00 deg.F) (Ref. AMM TASK 12-33-21-618-001) or (Ref. AMM TASK 12-33-21-618-001):
(a) For the cold weather maintenance - electrical power (Ref. AMM TASK 12-31-24-660-001).
(3) Start and operate the APU If a GTCP 36-300 APU is installed.
(a) Open the APU access door 315AL.
(b) If oil heater operates:
(4) Start and operate the APU If APS 3200 APU is installed.
(a) Open the APU access door 315AL.
(b) Blow hot air with a HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F) on the APU to increase the temperature of the APU oil to a minimum of -40 deg.C (-40.00 deg.F).
(c) Remove the HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F).
(d) Close the APU access door 315AL.
(e) Start and operate the APU (Ref. AMM TASK 49-00-00-860-005) (Ref. AMM TASK 49-00-00-860-005)
(5) Start and operate the APU If 131-9(A) APU is installed.
(a) Open the APU access door 315AL.
(c) Remove the HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F).
(d) Close the APU access door 315AL.
(e) Start and operate the APU (Ref. AMM TASK 49-00-00-860-008) (Ref. AMM TASK 49-00-00-860-008)
Subtask 12-31-49-660-053-A (1) ECB 59KD.
NOTE: Do not operate the ECB 59KD for more than 30 minutes at -40 deg.C (-40.00 deg.F) or lower.
(a) If the ECB was on the aircraft during the cold soak, make sure that the temperature of the ECB is higher than -40 deg.C (-40.00 deg.F). If the temperature of the ECB is lower than -40 deg.C (-40.00 deg.F), use a pre-conditioning procedure to increase the temperature of the ECB to a minimum of -40 deg.C (-40.00 deg.F) (Ref. AMM TASK 12-33-21-618-001) or (Ref. AMM TASK 12-33-21-618-001):
- through the Low Pressure (LP) ground connection (Ref. AMM TASK 12-33-21-618-001),
- the High Pressure (HP) ground connection (Ref. AMM TASK 12-33-21-618-001).
- If a GTCP 36-300 APU is installed
(Ref. AMM D/O 49-61-34-40) - If an APS 3200 APU is installed
(Ref. AMM TASK 49-61-34-400-002) - If a 131-9(A) APU is installed
(Ref. AMM TASK 49-61-34-400-003)
(a) For the cold weather maintenance - electrical power (Ref. AMM TASK 12-31-24-660-001).
(3) Start and operate the APU If a GTCP 36-300 APU is installed.
(a) Open the APU access door 315AL.
(b) If oil heater operates:
NOTE: If oil type I is used, it is not necessary to increase the temperature of the APU, but it is recommended.
- Blow hot air with a HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F) on the APU to increase the temperature of the APU oil to a minimum of -40 deg.C (-40.00 deg.F).
- Remove the HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg F).
- Close the APU access door 315AL.
- If oil type I is used, blow hot air with a HOT AIR BLOWER MAX OPERATING 55 deg. C (131 deg.F) on the APU to increase the temperature of the APU oil to a minimum of -40 deg.C (-40.00 deg.F).
- If oil type II is used, blow hot air with a HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F) on the APU to increase the temperature of the APU oil to a minimum of -29 deg.C (-20.2 deg.F).
- Remove the HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F).
- Close the APU access door 315AL.
(4) Start and operate the APU If APS 3200 APU is installed.
(a) Open the APU access door 315AL.
(b) Blow hot air with a HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F) on the APU to increase the temperature of the APU oil to a minimum of -40 deg.C (-40.00 deg.F).
(c) Remove the HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F).
(d) Close the APU access door 315AL.
(e) Start and operate the APU (Ref. AMM TASK 49-00-00-860-005) (Ref. AMM TASK 49-00-00-860-005)
(5) Start and operate the APU If 131-9(A) APU is installed.
(a) Open the APU access door 315AL.
NOTE: If oil type I is used, it is not necessary to increase the temperature of the APU but it is recommended.
(b) Blow hot air with a HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F) on the APU to increase the temperature of the APU oil to a minimum of -40 deg.C (-40.00 deg.F). (c) Remove the HOT AIR BLOWER MAX OPERATING 55 deg.C (131 deg.F).
(d) Close the APU access door 315AL.
(e) Start and operate the APU (Ref. AMM TASK 49-00-00-860-008) (Ref. AMM TASK 49-00-00-860-008)
E. Turn-Around Time
For turn-around in cold weather conditions, when it is not pratical to remove equipment, it is recommended to keep the APU in operation. In this configuration :
For turn-around in cold weather conditions, when it is not pratical to remove equipment, it is recommended to keep the APU in operation. In this configuration :
- the temperature in the cabin will not decrease,
- no specific cold weather maintenance practices are necessary for the APU system.