APU Start by External Power
TASK 49-00-00-860-005-A
APU Start by External Power
Start and operate the APU to do maintenance tasks.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 49-00-00-941-067-A ** ON A/C NOT FOR ALL
Subtask 49-00-00-860-065-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:25:30 UTC
APU Start by External Power
WARNING:
MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT.
THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
WARNING:
WHILE THE APU OPERATES, DO NOT GO INTO THESE AREAS:
- THE AREA BEHIND THE APU EXHAUST DUCT: 25m (82ft.) REARWARD OF THE DUCT, MORE THAN 3m (10ft.) ABOVE THE GROUND, AND THE WIDTH OF THE HORIZONTAL STABILIZER
- THE AREA AROUND THE APU AIR-INTAKE: 2m (7ft) AROUND THE INTAKE
- THE AREA OF THE OIL-COOLER OUTLET.
WARNING:
DO NOT START THE APU WHEN THE AIRCRAFT IS IN THE HANGAR. WHEN THE APU OPERATES, THERE ARE RISKS OF INJURY FROM HIGH TEMPERATURES AND DANGEROUS FUMES (THAT CAN FILL THE HANGAR). MAKE SURE THAT PERSONS STAY AWAY FROM THE EXHAUST DUCT. THE EXHAUST DUCT IS DANGEROUS.
CAUTION:
DO NOT START OR TRY TO START THE APU MORE THAN THREE TIMES, ONE AFTER THE OTHER. AFTER THE THIRD TIME, THERE MUST BE A MINIMUM OF ONE HOUR BEFORE YOU START OR TRY TO START THE APU AGAIN. THIS MAKES SURE THAT THE TEMPERATURE OF THE STARTER MOTOR DECREASES SUFFICIENTLY.
CAUTION:
DO NOT START THE APU WITH ACCESS DOORS 315AL AND 316AR OPEN/REMOVED.
THE APU FIRE EXTINGUISHER SYSTEM IS NOT SUFFICIENT TO EXTINGUISH A FIRE IF THE ACCESS DOORS 315AL AND 316AR ARE OPEN/REMOVED.
CAUTION:
DO NOT TRY TO START THE APU AGAIN DURING A REFUEL/DEFUEL PROCEDURE AFTER AN AUTOMATIC SHUTDOWN OR FAILED APU START. IF YOU DO, THERE IS A RISK OF INJURY AND/OR DAMAGE.
CAUTION:
OBEY THE SAFETY PRECAUTIONS.
1. Reason for the JobStart and operate the APU to do maintenance tasks.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-33-21-618-001-A | Pre-conditioning through the LP Ground Connection (Aircraft Electrical Power Available) |
| TASK 12-33-21-618-001-A-01 | Pre-conditioning through the HP Ground Connection |
| TASK 12-33-21-618-001-A-02 | Pre-conditioning with the APU |
| TASK 12-33-21-618-001-A-03 | Pre-conditioning through the LP Ground Connection (Aircraft Electrical Power Not Available) |
| TASK 23-44-00-860-001-A | Operation of the Service Interphone System |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 26-22-00-710-001-A | Operational Test of the APU Fire-Extinguishing Loop/Squib |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 31-32-00-860-001-A | Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-001-A | Close the APU Doors after Access |
Subtask 49-00-00-941-067-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that the danger areas are clear of persons and/or equipment.
(3) If an emergency or a malfunction occurs during operation of the APU, do the emergency shutdown procedure immediately. You can start the emergency shutdown from:
Subtask 49-00-00-860-064-A ** ON A/C NOT FOR ALL (1) Make sure that the danger areas are clear of persons and/or equipment.
WARNING:
WHILE THE APU OPERATES, DO NOT GO INTO THESE AREAS:
(2) Close the APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-410-001). - THE AREA BEHIND THE APU EXHAUST DUCT: 25m (82ft.) REARWARD OF THE DUCT, MORE THAN 3m (10ft.) ABOVE THE GROUND, AND THE WIDTH OF THE HORIZONTAL STABILIZER
- THE AREA AROUND THE APU AIR-INTAKE: 2m (7ft) AROUND THE INTAKE
- THE AREA OF THE OIL-COOLER OUTLET.
(3) If an emergency or a malfunction occurs during operation of the APU, do the emergency shutdown procedure immediately. You can start the emergency shutdown from:
- The APU FIRE PUSH pushbutton switch on the panel 20VU.
- The APU SHUT OFF pushbutton switch on the panel 108VU.
NOTE: Do the emergency shutdown immediately if fire, smoke, unusual noise, fuel or oil leakage occurs.
B. Aircraft Maintenance Configuration
(1) Open the access door 811 (Ref. AMM TASK 52-41-00-010-002).
(a) Put the WARNING NOTICE(S) in position on the opened access door 811 which tells persons not to close the door.
(2) Energize the aircraft electrical circuits.
(a) On the ELEC section on the panel 35VU:
(3) Make sure that there is sufficient fuel in the A/C fuel system.
(4) Depressurize the aircraft hydraulic systems
(Ref. AMM TASK 29-00-00-864-001).
(5) Make a service interphone connection from the cockpit to the APU compartment area (Ref. AMM TASK 23-44-00-860-001).
(6) On the AIR COND section of the panel 30VU:
(Ref. AMM TASK 31-60-00-860-001).
(a) On the ECAM control panel, push the APU pushbutton switch (on the lower ECAM DU, the APU page comes on).
(9) Make sure that the APU fire and overheat detection system and the APU fire extinguishing system are operational (Ref. AMM TASK 26-22-00-710-001).
(10) Remove the APU air intake and exhaust blanking plugs.
(11) If not required during operation of the APU, remove the ground support equipment, the special and standard tools and all other items.
Subtask 49-00-00-865-089-A ** ON A/C NOT FOR ALL (1) Open the access door 811 (Ref. AMM TASK 52-41-00-010-002).
(a) Put the WARNING NOTICE(S) in position on the opened access door 811 which tells persons not to close the door.
(2) Energize the aircraft electrical circuits.
(a) On the ELEC section on the panel 35VU:
- Make sure that the BAT 1 and BAT 2 pushbutton switches are in the AUTO position (the OFF and FAULT legends are off).
(3) Make sure that there is sufficient fuel in the A/C fuel system.
(4) Depressurize the aircraft hydraulic systems
(Ref. AMM TASK 29-00-00-864-001).
(5) Make a service interphone connection from the cockpit to the APU compartment area (Ref. AMM TASK 23-44-00-860-001).
(6) On the AIR COND section of the panel 30VU:
- Make sure that the APU BLEED pushbutton switch is in the off position (the ON and FAULT legends are off).
- Make sure that the X BLEED selector switch is in the AUTO position.
- Make sure that both ENG MASTER control switches are in OFF position.
(Ref. AMM TASK 31-60-00-860-001).
(a) On the ECAM control panel, push the APU pushbutton switch (on the lower ECAM DU, the APU page comes on).
(9) Make sure that the APU fire and overheat detection system and the APU fire extinguishing system are operational (Ref. AMM TASK 26-22-00-710-001).
(10) Remove the APU air intake and exhaust blanking plugs.
(11) If not required during operation of the APU, remove the ground support equipment, the special and standard tools and all other items.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | APU/FUEL/BLOW OFF/PUMP | 2QC | B14 |
| 121VU | APU/FUEL/BLOW OFF/CTL | 1QC | K39 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP B | 2WG | L44 |
| 121VU | APU/FIRE AND OVHT/DET/LOOP A | 1WG | L43 |
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FIRE/EXTIG/SQUIB/B | 2WF | L39 |
| 121VU | APU/FIRE/EXTIG/SQUIB/A | 1WF | L38 |
| 121VU | APU/FIRE/LP VALVE/NORM | 4WF | M42 |
| 121VU | APU/FIRE/LP VALVE/STBY | 3WF | M41 |
| 121VU | APU/FUEL/LP VALVE/CTL | 1QF | M40 |
| 121VU | APU/FUEL/LP VALVE/SPLY | 2QF | M39 |
| 121VU | APU/FUEL/PUMP/CTL | 3QC | M38 |
Subtask 49-00-00-860-065-B ** ON A/C NOT FOR ALL
CAUTION:
DO NOT OPERATE THE APU WHEN THE MAIN BATTERIES ARE OFF. IF YOU OPERATE THE APU IN THESE CONDITIONS, YOU CAN CAUSE THESE RESULTS:
A. Start and Operate the APU - IF THERE IS AN APU FIRE, THE APU FIRE-BOTTLES WILL NOT OPERATE
- THERE WILL BE NO DE-OILING OF THE APU DURING SHUT-DOWN. THIS WILL CAUSE SMOKE IN THE CABIN
- THERE WILL BE NO COOL-DOWN SEQUENCE OF THE APU
- THE IGV WILL NOT CLOSE FULLY. THIS CAN CAUSE PROBLEMS WHEN YOU START THE APU AGAIN.
NOTE: If you must start the APU with external power, make sure that the batteries are set to ON. If the batteries are not set to ON, the APU cannot start and stop.
(1) Make sure that there is a minimum interval of three seconds between the time you set the APU MASTER SW pushbutton switch to ON and the time you set the APU START pushbutton switch to ON. | ACTION | RESULT |
|---|---|
1.On overhead control and indicator panel 25VU, on the APU section:
| On overhead control and indicator panel 25VU, on the APU section:
|
| 2.Get access to the APU menu page in the SYSTEM REPORT/TEST (Ref. AMM TASK 31-32-00-860-001). | On the MCDU:
|
3.On the MCDU:
| On the MCDU:
|
4.On the MCDU:
| On the MCDU:
|
5.On the MCDU:
| On the MCDU:
|
6.On the MCDU:
| On the MCDU:
|
7.On overhead control and indicator panel 25VU, on the APU section:
| On overhead control and indicator panel 25VU, on the APU section:
NOTE: The Electronic Control Box (ECB) (59KD) controls and monitors the APU start. |
| This is a nuisance fault of ECB software 2.02 and should be disregarded. | On the lower ECAM DU, on the APU page:
|
| At the end of the APU start sequence: | |
| | On overhead control and indicator panel 25VU, on the APU section:
|
| | On the lower ECAM DU, on the APU page:
|
| | On the upper ECAM DU, on the ENGINE/WARNING page:
|
NOTE: If necessary, the APU generator can energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
NOTE: If necessary, the APU can supply bleed air for the pre-conditioning (Ref. AMM TASK 12-33-21-618-001).