W DOC AIRBUS | AMM A320F

Open the Avionics Compartment Doors for Access


TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access


WARNING: BE CAREFUL WHEN YOU OPEN THE AVIONICS COMPARTMENT DOOR. IF YOU OPEN IT WITH TOO MUCH FORCE, IT CAN CLOSE AGAIN SUDDENLY. THIS CAN CAUSE INJURY TO YOUR HANDS IF THEY ARE ON THE EDGE OF THE OPENING.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
3. Job Set-up
Subtask 52-41-00-860-054-A
A. Aircraft Maintenance Configuration
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the applicable access door.
   (2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure
Subtask 52-41-00-010-053-A ** ON A/C NOT FOR ALL
WARNING: BE CAREFUL WHEN YOU OPEN THE AVIONICS COMPARTMENT DOOR. IF YOU OPEN IT WITH TOO MUCH FORCE, IT CAN CLOSE AGAIN SUDDENLY. THIS CAN CAUSE INJURY TO YOUR HANDS IF THEY ARE ON THE EDGE OF THE OPENING.
CAUTION: MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS. THIS PREVENTS DAMAGE TO THE OUTER SKIN.
A. Opening of Avionics Compartment Door 811 (Access Door)
   (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
   (2) Move the door handle to the OPEN position to unlock the access door.
   (3) Hold the door handle and push the access door up to move it inboard.
   (4) Release the door handle when the access door engages in the structural lock pins.
   (5) As a safety precaution, move the door handle to the CLOSED position and push it into its recess.
   (6) Make sure that the access door stays in its fully open position.
Subtask 52-41-00-010-053-B ** ON A/C NOT FOR ALL
WARNING: BE CAREFUL WHEN YOU OPEN THE AVIONICS COMPARTMENT DOOR. IF YOU OPEN IT WITH TOO MUCH FORCE, IT CAN CLOSE AGAIN SUDDENLY. THIS CAN CAUSE INJURY TO YOUR HANDS IF THEY ARE ON THE EDGE OF THE OPENING.
CAUTION: MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS. THIS PREVENTS DAMAGE TO THE OUTER SKIN.
A. Opening of Avionics Compartment Door 811 (Access Door)
   (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
   (2) Move the door handle to the OPEN position to unlock the access door.
   (3) Hold the door handle and push the access door up to move it inboard.
   (4) Release the door handle when the access door engages in the structural lock pins.
   (5) Make sure that the leaf spring of the fuselage beam engages in the locking angle of the access door.
   (6) As a safety precaution, move the door handle to the CLOSED position and push it into its recess.
Subtask 52-41-00-010-054-A
CAUTION: MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS. THIS PREVENTS DAMAGE TO THE OUTER SKIN.
B. Opening of the Avionics Compartment Door 812 (Access Door)
   (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
   (2) Move the door handle down to the OPEN position to unlock the access door.
   (3) Hold the door handle and push the access door up to move it inboard.
   (4) Release the door handle when the access door engages in the structural lock pin.
   (5) As a safety precaution, move the door handle to the CLOSED position and push it into its recess.
   (6) Make sure that the access door stays in its locked position.
Subtask 52-41-00-010-055-A
WARNING: BE CAREFUL WHEN YOU OPEN THE AVIONICS COMPARTMENT DOOR. IF YOU OPEN IT WITH TOO MUCH FORCE, IT CAN CLOSE AGAIN SUDDENLY. THIS CAN CAUSE INJURY TO YOUR HANDS IF THEY ARE ON THE EDGE OF THE OPENING.
C. Opening of the Avionics Compartment Door 822 (Access Door)
   (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
   (2) Move the door handle down to the OPEN position to unlock the access door.
   (3) Hold the door handle and push the access door up to move it inboard.
   (4) Release the door handle when the access door touches the structure.
   (5) As a safety precaution, move the door handle to the CLOSED position and push it into its recess.
   (6) Make sure that the access door stays in its fully open position.
Subtask 52-41-00-010-056-A
CAUTION: MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS. THIS PREVENTS DAMAGE TO THE OUTER SKIN.
D. Opening of the Avionics Compartment Door 824 (Access Door)
   (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
   (2) Move the door handle up to the OPEN position to unlock the access door.
   (3) Hold the door handle and push the access door up to move it inboard.
   (4) Release the door handle when the gas spring unit starts to move the access door in its open position.
NOTE: The gas spring unit moves the access door to its fully open position.
5. Close-up
Subtask 52-41-00-860-055-A
A. Put the aircraft back to the serviceable condition.
   (1) Remove the access platform(s).
   (2) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.01 03:45:55 UTC