Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 29-00-00-861-058-A Subtask 29-00-00-869-073-A
Subtask 29-00-00-864-058-A
[Rev.10 from 2021]
2026.04.01 03:55:52 UTC
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 134AR, 154AR, 197CB, 197EB, 198CB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 29-00-00-861-058-A Subtask 29-00-00-869-073-A
B. The following panel gives the circuit breakers for all hydraulic systems:
Subtask 29-00-00-865-066-A - For the Green hydraulic system use the circuit breakers 1702GK, 3801GX, 3802GX and 3803GX.
- For the Blue hydraulic system use the circuit breakers 2701GJ and 2702GJ.
- For the Yellow hydraulic system use the circuit breakers 3801GX, 3802GX and 3803GX.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-00-00-860-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R33 |
| ** ON A/C ALL | |||
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
D. Aircraft Maintenance Configuration
(1) For the Green and Yellow hydraulic systems:
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the HYD key (on the SD, the HYD page comes into view).
Subtask 29-00-00-010-067-A (1) For the Green and Yellow hydraulic systems:
- On overhead panel 40VU, set the PTU pushbutton switch to the OFF position and make sure that the OFF legend comes on.
- On overhead panel 40VU, set the applicable GREEN/ENG 1 PUMP and YELLOW/ENG 2 PUMP pushbutton switches to the FAULT/OFF position and make sure that the OFF legends come on.
(Ref. AMM TASK 31-60-00-860-001).
(3) On the ECAM control panel, push the HYD key (on the SD, the HYD page comes into view).
E. Get Access
(1) Open the access door of the ground service panel related to the hydraulic system:
4. Procedure(1) Open the access door of the ground service panel related to the hydraulic system:
Subtask 29-00-00-864-058-A
A. Check of the Depressurization of the Related Hydraulic System
(1) Make sure that there is no hydraulic supply from a ground power cart.
(2) On the SD, on the HYD page make sure that the pressure of the related hydraulic system shows 0 psi (0 bar).
Subtask 29-00-00-941-051-A (1) Make sure that there is no hydraulic supply from a ground power cart.
(2) On the SD, on the HYD page make sure that the pressure of the related hydraulic system shows 0 psi (0 bar).
B. Installation of the Warning Notices
(1) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the related hydraulic system:
5. Close-up(1) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the related hydraulic system:
NOTE: You must do this close-up only when you have completed the work.
Subtask 29-00-00-865-068-A A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 29-00-00-410-064-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R33 |
| ** ON A/C ALL | |||
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
B. Close Access
(1) Remove the WARNING NOTICE(S).
(2) Close the access door of the related ground service panel:
Subtask 29-00-00-860-051-A (1) Remove the WARNING NOTICE(S).
(2) Close the access door of the related ground service panel:
C. Put the aircraft back to the serviceable condition.
(1) For the Green and Yellow hydraulic systems:
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
(1) For the Green and Yellow hydraulic systems:
- On panel 40VU, set the PTU pushbutton switch to the AUTO position and make sure that the OFF legend goes off.
- On panel 40VU, set the related GREEN/ENG 1 PUMP and YELLOW/ENG 2 PUMP pushbutton switches to the AUTO position and make sure that the OFF lights go off.
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).