Pre-conditioning with the APU
TASK 12-33-21-618-001-A-02
Pre-conditioning with the APU
For maintenance procedures
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 12-33-21-865-054-A
Subtask 12-33-21-618-055-A
Subtask 12-33-21-860-053-A
[Rev.10 from 2021]
2026.03.31 22:58:14 UTC
Pre-conditioning with the APU
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
MAKE SURE THAT DURING THIS PROCEDURE THE AIRCRAFT IS IN ONE OF THESE THREE CONDITIONS:
- THE CABIN PRESSURE OUTFLOW VALVE IS OPEN.
- THE FWD AVIONICS COMPARTMENT ACCESS DOOR 811 IS OPEN.
- ONE OR MORE PASSENGER DOORS ARE OPEN.
CAUTION:
DO NOT USE CONDITIONED AIR FROM THE APU OR HIGH-PRESSURE GROUND UNIT AT THE SAME TIME AS AIR FROM THE LOW-PRESSURE GROUND UNIT. IF YOU DO NOT OBEY THIS PRECAUTION, DAMAGE TO THE CHECK VALVES OR THE AIRCRAFT CAN OCCUR.
NOTE: The APU supplies air to the air conditioning packs 10HM/11HM.
1. Reason for the JobFor maintenance procedures
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 49-00-00-860-005-A | APU Start by External Power |
| TASK 49-00-00-860-005-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-006-A | APU Shutdown by External Power |
| TASK 49-00-00-860-006-A-01 | APU Shutdown by Batteries |
| TASK 49-00-00-860-008-A | APU Start by External Power |
| TASK 49-00-00-860-008-A-01 | APU Start by Batteries |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
Subtask 12-33-21-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 12-33-21-860-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/FLOW/CTL &/IND1 | 1HB | D07 |
| ** ON A/C ALL | |||
| 49VU | AIR COND/AVNCS VENT/CTL | 6HQ | D06 |
| 49VU | AIR COND/AVNCS VENT/CTL | 5HQ | D05 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/FLOW/MIXER/FLAP | 3HB | V22 |
| 122VU | AIR COND/FLOW/CTL AND IND/2 | 2HB | V21 |
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS2 | 4HK | V20 |
| 122VU | AIR COND/ZONE TEMP CTL/28VDC/SYS1 | 3HK | V19 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS2 | 2HK | V18 |
| 122VU | AIR COND/ZONE TEMP CTL/115VAC/SYS1 | 1HK | V17 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/28VDC | 23HH | W21 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/28VDC | 3HH | X21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/28VDC | 24HH | Y21 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/28VDC | 4HH | Y19 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
| ** ON A/C ALL | |||
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL | 5HU | U21 |
| 122VU | AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY | 6HU | U19 |
| 122VU | AIR COND/RECIRC FAN/R/CTL | 11HG | W20 |
| 122VU | AIR COND/RECIRC FAN/R/SPLY | 3HG | W18 |
| 122VU | AIR COND/RECIRC FAN/L/CTL | 2HG | X20 |
| 122VU | AIR COND/RECIRC FAN/L/SPLY | 1HG | X18 |
| 122VU | AIR COND/AVNCS/VENT/MONG | 3HQ | Y17 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AE02 |
| ** ON A/C ALL | |||
| 123VU | AVNCS VENT/BLOWER/FAN | 1HQ | AD10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AVNCS VENT/EXTC/FAN | 2HQ | AC04 |
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) On the panel 30VU make sure that:
Subtask 12-33-21-941-054-A (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) On the panel 30VU make sure that:
- the PACK 1 and the PACK 2 pushbutton switches are in the off position (the OFF legends are on).
- the COCKPIT, the FWD CABIN and the AFT CABIN temperature selectors are at the 12 o'clock position,
- the HOT AIR pushbutton switch is in the off position (the OFF legend is on).
C. Do at least one of the following safety precautions:
(1) Make sure that the cabin pressure Outflow Valve (OFV) is open.
(a) On the overhead panel, on the CABIN PRESS section of the control panel 25VU:
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the FWD avionics compartment access door 811.
(b) Open the FWD avionics compartment access door 811.
(3) Or make sure that at least one cabin door is safe in open position.
4. Procedure(1) Make sure that the cabin pressure Outflow Valve (OFV) is open.
(a) On the overhead panel, on the CABIN PRESS section of the control panel 25VU:
- Put a warning notice in position to tell persons not to close the OFV.
(a) Put the ACCESS PLATFORM 2M (6 FT) in position below the FWD avionics compartment access door 811.
(b) Open the FWD avionics compartment access door 811.
(3) Or make sure that at least one cabin door is safe in open position.
- Put a WARNING NOTICE(S) in position to tell persons not to close the cabin door.
Subtask 12-33-21-618-055-A
A. Pre-conditioning with the APU
(1) Do the start procedure of the Auxiliary Power Unit (APU):
Subtask 12-33-21-618-058-A (1) Do the start procedure of the Auxiliary Power Unit (APU):
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86) or
- For APS 3200 APU (Ref. AMM TASK 49-00-00-860-005) or
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-008).
NOTE: After the APU starts, Airbus recommends you to wait for a minimum of 3 minutes (a warm-up period for the APU) before you select the APU BLEED pushbutton switch.
(2) On panel 30VU: - Push the APU BLEED pushbutton switch (the ON legend comes on)
- Push the PACK 1 and the PACK 2 pushbutton switches (the OFF legends go off)
- Push the HOT AIR pushbutton switch (the OFF legend goes off)
- Push the X BLEED selector switch to the AUTO position.
- Push the CAB FANS pushbutton switch (the OFF legend goes off).
B. When the pre-conditioning is no longer necessary:
(1) On the panel 30VU:
5. Close-up(1) On the panel 30VU:
- push the PACK 1 and the PACK 2 pushbutton switches to the off position (the OFF legends come on),
- push the HOT AIR pushbutton switch to the off position (the OFF legend comes on),
- push the APU BLEED pushbutton switch to the off position (the ON legend goes off).
- push the CAB FANS pushbutton switch to the off position (the OFF legend comes on).
Subtask 12-33-21-860-053-A
A. Aircraft Maintenance Configuration
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
(3) Close the FWD avionics compartment access door 811 if opened.
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
(3) Close the FWD avionics compartment access door 811 if opened.
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Air Condition Panel