W DOC AIRBUS | AMM A320F

APU Shutdown by Batteries (131-9(A))


TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))


FIN: 4005KM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
811
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 49-00-00-860-122-A ** ON A/C NOT FOR ALL
A. Not applicable.
4. Procedure
Subtask 49-00-00-860-123-A ** ON A/C NOT FOR ALL
CAUTION: OBEY THE SAFETY PRECAUTIONS.
A. Shutdown of the APU
ACTION
RESULT
1.On the APU section on the panel 25VU:
  • push the APU MASTER SW pushbutton switch to the off position.
On the APU section on the panel 25VU:
  • the ON legend in the APU MASTER SW pushbutton switch goes off.

After the cooldown cycle is complete:
  • the APU shutdown sequence starts.

On the APU section on the panel 25VU:
  • the AVAIL legend in the APU START pushbutton switch goes off.
5. Close-up
Subtask 49-00-00-860-124-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Close the access door 811 (Ref. AMM TASK 52-41-00-410-002).
   (2) Remove the WARNING NOTICE(S).
   (3) Put the aircraft back to its initial configuration.
NOTE: Wait until the APU flap is fully closed (approximately 2 minutes after the APU AVAIL light goes off) before you set the BAT 1 and BAT 2 p/bsw to the off position.
[Rev.10 from 2021] 2026.04.01 01:25:44 UTC