Subtask 52-41-00-860-056-A
Subtask 52-41-00-410-053-A ** ON A/C NOT FOR ALL
(1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
(2) Move the door handle to the OPEN position and pull it outboard to release the access door from the structural lock pins.
(3) Release the door handle when the access door engages in the structural lock pin.
(4) Do not touch the door frame edge of the fuselage with your hands.
(5) Move the door handle to the fully CLOSED position.
(6) Push the door handle into its recess.
Subtask 52-41-00-410-053-B ** ON A/C NOT FOR ALL
(1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
(2) Move the door handle to the OPEN position and pull it outboard to release the access door from the structural lock pins.
(3) Pull the door handle until the leaf spring disengages from the locking angle.
(4) Do not touch the door frame edge of the fuselage with your hands.
(5) Carefully move the access door down into the door opening.
(6) Move the door handle to the fully CLOSED position.
(7) Push the door handle into its recess.
Subtask 52-41-00-410-054-A
(1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
(2) Move the door handle to the OPEN position and pull it outboard to release the access door from the structural lock pin.
(3) Do not touch the door frame edge of the fuselage with your hands.
(4) Pull the door handle to move the access door down into the door opening.
(5) Move the door handle to the fully CLOSED position.
(6) Push the door handle into its recess.
Subtask 52-41-00-410-055-A
(1) Push and hold the button of the door handle until the door releases and moves away from its recess.
(2) Move the door handle to the OPEN position.
(3) Do not touch the door frame edge of the fuselage with your hands.
(4) Pull the door handle to move the access door down into the door opening.
(5) Move the door handle to the fully CLOSED position.
(6) Push the door handle into its recess.
Subtask 52-41-00-410-056-A
(1) Pull the door handle to move the access door down over its horizontal level.
(3) Pull the door handle to move the access door down into the door opening.
(4) Move the door handle to the fully CLOSED position.
(5) Push the door handle into its recess.
5. Close-up
Subtask 52-41-00-860-057-A
[Rev.10 from 2021]
2026.04.01 01:44:28 UTC
Close the Avionics Compartment Doors after Access
CAUTION:
WHEN YOU CLOSE THE AVIONICS COMPARTMENT DOOR, MAKE SURE THAT YOUR HANDS ARE NOT ON THE EDGE OF THE OPENING.
THE DOOR CLOSES QUICKLY AT THE END OF THE MOVEMENT AND CAN CAUSE INJURY TO YOUR HANDS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 52-41-00-860-056-A
A. Aircraft Maintenance Configuration
(1) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is below the opened access door.
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
4. Procedure(1) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is below the opened access door.
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-41-00-410-053-A ** ON A/C NOT FOR ALL
CAUTION:
MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS.
THIS PREVENTS DAMAGE TO THE OUTER SKIN.
CAUTION:
WHEN YOU CLOSE THE AVIONICS COMPARTMENT DOOR, MAKE SURE THAT YOUR HANDS ARE NOT ON THE EDGE OF THE OPENING.
THE DOOR CLOSES QUICKLY AT THE END OF THE MOVEMENT AND CAN CAUSE INJURY TO YOUR HANDS.
A. Close Avionics Compartment Door 811 (Access Door) (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
(2) Move the door handle to the OPEN position and pull it outboard to release the access door from the structural lock pins.
(3) Release the door handle when the access door engages in the structural lock pin.
(4) Do not touch the door frame edge of the fuselage with your hands.
(5) Move the door handle to the fully CLOSED position.
(6) Push the door handle into its recess.
NOTE: If the door handle is not in the fully CLOSED position before you push it into its recess, a door indication error could occur.
CAUTION:
MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS.
THIS PREVENTS DAMAGE TO THE OUTER SKIN.
CAUTION:
WHEN YOU CLOSE THE AVIONICS COMPARTMENT DOOR, MAKE SURE THAT YOUR HANDS ARE NOT ON THE EDGE OF THE OPENING.
THE DOOR CLOSES QUICKLY AT THE END OF THE MOVEMENT AND CAN CAUSE INJURY TO YOUR HANDS.
A. Close Avionics Compartment Door 811 (Access Door) (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
(2) Move the door handle to the OPEN position and pull it outboard to release the access door from the structural lock pins.
(3) Pull the door handle until the leaf spring disengages from the locking angle.
(4) Do not touch the door frame edge of the fuselage with your hands.
(5) Carefully move the access door down into the door opening.
(6) Move the door handle to the fully CLOSED position.
(7) Push the door handle into its recess.
NOTE: If the door handle is not in the fully CLOSED position before you push it into its recess, a door indication error could occur.
CAUTION:
MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS.
THIS PREVENTS DAMAGE TO THE OUTER SKIN.
CAUTION:
WHEN YOU CLOSE THE AVIONICS COMPARTMENT DOOR, MAKE SURE THAT YOUR HANDS ARE NOT ON THE EDGE OF THE OPENING.
THE DOOR CLOSES QUICKLY AT THE END OF THE MOVEMENT AND CAN CAUSE INJURY TO YOUR HANDS.
B. Close Avionics Compartment Door 812 (Access Door) (1) Push and hold the button of the door handle until the door handle releases and moves away from its recess.
(2) Move the door handle to the OPEN position and pull it outboard to release the access door from the structural lock pin.
(3) Do not touch the door frame edge of the fuselage with your hands.
(4) Pull the door handle to move the access door down into the door opening.
(5) Move the door handle to the fully CLOSED position.
(6) Push the door handle into its recess.
CAUTION:
MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS.
THIS PREVENTS DAMAGE TO THE OUTER SKIN.
CAUTION:
WHEN YOU CLOSE THE AVIONICS COMPARTMENT DOOR, MAKE SURE THAT YOUR HANDS ARE NOT ON THE EDGE OF THE OPENING.
THE DOOR CLOSES QUICKLY AT THE END OF THE MOVEMENT AND CAN CAUSE INJURY TO YOUR HANDS.
C. Close Avionics Compartment Door 822 (Access Door) (1) Push and hold the button of the door handle until the door releases and moves away from its recess.
(2) Move the door handle to the OPEN position.
(3) Do not touch the door frame edge of the fuselage with your hands.
(4) Pull the door handle to move the access door down into the door opening.
(5) Move the door handle to the fully CLOSED position.
(6) Push the door handle into its recess.
CAUTION:
MAKE SURE THAT THE DOOR HANDLE IS ALIGNED WITH THE HANDLE RECESS BEFORE YOU PUSH IT INTO ITS RECESS.
THIS PREVENTS DAMAGE TO THE OUTER SKIN.
CAUTION:
WHEN YOU CLOSE THE AVIONICS COMPARTMENT DOOR, MAKE SURE THAT YOUR HANDS ARE NOT ON THE EDGE OF THE OPENING.
THE DOOR CLOSES QUICKLY AT THE END OF THE MOVEMENT AND CAN CAUSE INJURY TO YOUR HANDS.
D. Close Avionics Compartment Door 824 (Access Door) (1) Pull the door handle to move the access door down over its horizontal level.
NOTE: When the access door moves below the horizontal level, the gas spring unit operates to lower the access door automatically.
(2) Make sure that your hands do not touch the door frame edge of the fuselage. (3) Pull the door handle to move the access door down into the door opening.
(4) Move the door handle to the fully CLOSED position.
(5) Push the door handle into its recess.
NOTE: If the door handle is not in the fully CLOSED position before you push it into its recess, a door indication error could occur.
Subtask 52-41-00-860-057-A
A. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Opening and Closing Procedure of Avionics Compartment Door 811