APU Shutdown by Batteries
TASK 49-00-00-860-006-A-01
APU Shutdown by Batteries
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 49-00-00-860-132-A ** ON A/C NOT FOR ALL
Subtask 49-00-00-860-133-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 49-00-00-860-134-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:25:34 UTC
APU Shutdown by Batteries
FIN: 4005KM ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 49-00-00-860-132-A ** ON A/C NOT FOR ALL
A. Not applicable.
4. ProcedureSubtask 49-00-00-860-133-A ** ON A/C NOT FOR ALL
CAUTION:
OBEY THE SAFETY PRECAUTIONS.
A. Shutdown of the APU | ACTION | RESULT |
|---|---|
1.On the APU section on the panel 25VU:
| On the APU section on the panel 25VU:
|
| | After the cooldown cycle is complete:
|
| | On the APU section on the panel 25VU:
|
Subtask 49-00-00-860-134-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Close the access door 811 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the WARNING NOTICE(S).
(3) Put the aircraft back to its initial configuration.
(1) Close the access door 811 (Ref. AMM TASK 52-41-00-410-002).
(2) Remove the WARNING NOTICE(S).
(3) Put the aircraft back to its initial configuration.
NOTE: Wait until the APU flap is fully closed (approx. 2 minutes after the APU AVAIL light goes off) before you set the BAT 1 and BAT 2 p/bsw to the off position.