W DOC AIRBUS | AMM A320F

Pre-conditioning through the HP Ground Connection


TASK 12-33-21-618-001-A-01
Pre-conditioning through the HP Ground Connection


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: MAKE SURE THAT DURING THIS PROCEDURE THE AIRCRAFT IS IN ONE OF THESE THREE CONDITIONS:
  • THE CABIN PRESSURE OUTFLOW VALVE IS OPEN.
  • THE FWD AVIONICS COMPARTMENT ACCESS DOOR 811 IS OPEN.
  • ONE OR MORE PASSENGER DOORS ARE OPEN.
YOU MUST ATTACH A WARNING NOTICE TO THE OPEN DOORS TO TELL PERSONS NOT TO CLOSE THEM. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
CAUTION: DO NOT USE CONDITIONED AIR FROM THE APU OR HIGH-PRESSURE GROUND UNIT AT THE SAME TIME AS AIR FROM THE LOW-PRESSURE GROUND UNIT. IF YOU DO NOT OBEY THIS PRECAUTION, DAMAGE TO THE CHECK VALVES OR THE AIRCRAFT CAN OCCUR.
CAUTION: MAKE SURE THAT THE GROUND-AIR SUPPLY IS FREE FROM OIL CONTAMINATION. OIL CONTAMINATION CAN CAUSE THE SMELL OF OIL IN THE CABIN AND MAKE THE AIR-CONDITIONING PACKS UNSERVICEABLE.
CAUTION: MAKE SURE THAT THE GROUND AIR-SUPPLY UNIT IS NOT TOO NEAR THE AIRCRAFT AND THAT THE ENGINE EXHAUST PIPE OF THE GROUND AIR- SUPPLY UNIT POINTS AWAY FROM THE AIRCRAFT. HEAT FROM THIS UNIT AND FROM THE EXHAUST CAN CAUSE DAMAGE TO THE AIRCRAFT STRUCTURE.
CAUTION: DO NOT USE A GROUND POWER UNIT WITH A CAPACITY LESS THAN 90 KVA. IF YOU USE A LESS POWERFUL UNIT:
  • AN OVERLOAD OF THE GROUND POWER UNIT COULD OCCUR
  • IT COULD BE NECESSARY TO RESET MANY COMPUTERS ON THE AIRCRAFT.
NOTE: The ground air-supply unit supplies air to the air conditioning packs 10HM/11HM.
1. Reason for the Job
For maintenance procedures
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191DB, 811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
F Air Condition Panel ** ON A/C NOT FOR ALL
F Air Condition Panel ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 12-33-21-865-053-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/FLOW/CTL &/IND11HBD07
** ON A/C ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
49VUAIR COND/AVNCS VENT/CTL5HQD05
** ON A/C NOT FOR ALL
122VUAIR COND/FLOW/MIXER/FLAP3HBV22
122VUAIR COND/FLOW/CTL AND IND/22HBV21
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS24HKV20
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS13HKV19
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS22HKV18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS11HKV17
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C ALL
122VUAIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL5HUU21
122VUAIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY6HUU19
122VUAIR COND/RECIRC FAN/R/CTL11HGW20
122VUAIR COND/RECIRC FAN/R/SPLY3HGW18
122VUAIR COND/RECIRC FAN/L/CTL2HGX20
122VUAIR COND/RECIRC FAN/L/SPLY1HGX18
122VUAIR COND/AVNCS/VENT/MONG3HQY17
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAE02
** ON A/C ALL
123VUAVNCS VENT/BLOWER/FAN1HQAD10
** ON A/C NOT FOR ALL
123VUAVNCS VENT/EXTC/FAN2HQAC04
Subtask 12-33-21-860-050-A
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
   (3) On the panel 30VU make sure that:
  • the PACK 1 and the PACK 2 pushbutton switches are in the on position (the FAULT legends are on and the OFF legends are off),
  • the COCKPIT, FWD CABIN and AFT CABIN temperature selectors are at the 12 o'clock position,
  • the HOT AIR pushbutton switch is in the on position (the OFF legend is off),
  • the X BLEED rotary switch is set to the OPEN position.
   (4) On the panel 22VU make sure that the CAB FANS pushbutton switch is in the on position (the OFF legend is off).
Subtask 12-33-21-010-054-A
C. Get Access
   (1) Open the access door 191DB.
   (2) Connect the GROUND AIR SUPPLY UNIT (HIGH PRESSURE) to the aircraft High Pressure (HP) connector(s).
Subtask 12-33-21-941-053-A
D. Do at least one of the following safety precautions:
   (1) Make sure that the cabin pressure Outflow Valve (OFV) is open.
     (a) On the overhead panel, on the CABIN PRESS section of the control panel 25VU:
  • Put a warning notice in position to tell persons not to close the OFV.

   (2) Or make sure that the FWD avionics compartment access door 811 is safe in open position.
     (a) Put the ACCESS PLATFORM 2M (6 FT) in position below the FWD avionics compartment access door 811.
     (b) Open the FWD avionics compartment access door 811.

   (3) Or make sure that at least one cabin door is safe in open position.
  • Put a WARNING NOTICE(S) in position to tell persons not to close the cabin door.

4. Procedure
Subtask 12-33-21-618-054-A ** ON A/C NOT FOR ALL
A. Pre-conditioning through the HP Ground Connection
   (1) Start the ground air-supply unit and make sure that:
  • the airflow is between 54 kg.min (119.0496 lb.min) and 78 kg.min (171.9605 lb.min),
  • the supplied air pressure is not more than 4.1 bar (59.4655 psi),
  • the supplied air temperature does not go above 260 deg.C (500.00 deg.F).
NOTE: On the panel 30VU:
On the PACK 1 and the PACK 2 pushbutton switches the FAULT legends go off when the flow control valves open.
   (2) On the AIR BLEED page of the ECAM lower DU, make sure that the pack discharge-temperature indication is normal (i.e. green indication).
Subtask 12-33-21-618-054-B ** ON A/C NOT FOR ALL
A. Pre-conditioning through the HP Ground Connection
   (1) Start the ground air-supply unit and make sure that:
  • the airflow is between 63 kg.min (138.8912 lb.min) and 96 kg.min (211.6437 lb.min),
  • the supplied air pressure is not more than 4.1 bar (59.4655 psi),
  • the supplied air temperature does not go above 260 deg.C (500.00 deg.F).
NOTE: On the panel 30VU:
On the PACK 1 and the PACK 2 pushbutton switches the FAULT legends go off when the flow control valves open.
   (2) On the AIR BLEED page of the ECAM lower DU, make sure that the pack discharge-temperature indication is normal (i.e. green indication).
Subtask 12-33-21-618-057-A
B. When the pre-conditioning is no longer necessary:
   (1) On the panel 30VU:
  • push the PACK 1 and the PACK 2 pushbutton switches to the off position (the OFF legends come on).
  • push the HOT AIR pushbutton switch to the off position (the OFF legend comes on).
   (2) On the panel 22VU:
  • push the CAB FANS pushbutton switch to the off position (the OFF legend comes on).
   (3) Stop the ground air-supply unit.
5. Close-up
Subtask 12-33-21-410-054-A
A. Close Access
   (1) Disconnect and remove the ground air-supply unit from the aircraft High Pressure (HP) connector(s).
   (2) Close the access door 191DB.
   (3) Close the FWD avionics compartment access door 811 if opened.
   (4) Remove the WARNING NOTICE(S).
   (5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 12-33-21-860-051-A
B. Aircraft Maintenance Configuration
   (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (2) De-energize the aircraft electrical circuits. (Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.03.31 22:58:13 UTC