W DOC AIRBUS | AMM A320F

Detailed Inspection of Pylon Spigot Receptacle Upper Surface, including Fitting Bore, and Upper Spar Surrounding Surface


TASK 54-51-00-200-010-A
Detailed Inspection of Pylon Spigot Receptacle Upper Surface, including Fitting Bore, and Upper Spar Surrounding Surface


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
ZONE: 415
ZONE: 425
1. Reason for the Job
Refer to the MPD TASK: 545117-01
DETAILED INSPECTION OF PYLON SPIGOT RECEPTACLE UPPER SURFACE, INCLUDING FITTING BORE, AND UPPER SPAR SURROUNDING SURFACE
NOTE: The effectivity of this task is "ALL". To know if this task is applicable to your aircraft, refer to the MPD task applicability.
The information on weight variant groups is given in the MPD and SRM introductions.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
415
LOWER PYLON
425
LOWER PYLON
415BL, 415BR, 425BL, 425BR
471BL, 471BR, 481BL, 481BR
471AL, 472AR, 481AL, 482AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
TASK 54-51-21-000-001-A
Removal of the Pylon Lateral Access-Doors
TASK 54-51-21-400-001-A
Installation of the Pylon Lateral Access-Doors
TASK 54-51-41-000-001-A
Removal of the Spigot Ball Joint
TASK 54-51-41-000-001-B
Removal of the Spigot Ball Joint
TASK 54-51-41-400-001-A
Installation of the Spigot Ball Joint
TASK 54-51-41-400-001-B
Installation of the Spigot Ball Joint
TASK 54-53-11-000-002-A
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-000-002-B
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-A
Installation of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-B
Installation of the Pylon-to-Wing Access Panels
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
SRM 511100
(for corrective action)
SRM 512200
(for corrective action)
F Pylon Spigot - Receptacle Fitting ** ON A/C NOT FOR ALL
F Pylon Spigot - Receptacle Fitting ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 54-51-00-941-061-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 54-51-00-040-059-A ** ON A/C NOT FOR ALL
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-51-00-040-059-B ** ON A/C NOT FOR ALL
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-012).
Subtask 54-51-00-010-060-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon, in zones 410 and 470
     (b) For the right pylon, in zones 420 and 480.
   (2) Remove the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-002):
     (a) For the left pylon: 471AL 472AR
     (b) For the right pylon: 481AL 482AR.
   (3) Remove the pylon lateral access-doors (Ref. AMM TASK 54-51-21-000-001):
     (a) For the left pylon: 415BL 415BR
     (b) For the right pylon: 425BL 425BR.
Subtask 54-51-00-010-060-C ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon, in zones 410 and 470
     (b) For the right pylon, in zones 420 and 480.
   (2) Remove the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-002):
     (a) For the left pylon: 471BL 471BR
     (b) For the right pylon: 481BL 481BR.
   (3) Remove the pylon lateral access-doors (Ref. AMM TASK 54-51-21-000-001):
     (a) For the left pylon: 415BL 415BR
     (b) For the right pylon: 425BL 425BR.
Subtask 54-51-00-020-062-A ** ON A/C NOT FOR ALL
D. Removal of the Spigot Ball Joint
   (1) Remove the spigot ball joint (Ref. AMM TASK 54-51-41-000-001).
Subtask 54-51-00-110-062-A ** ON A/C NOT FOR ALL
E. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 54-51-00-220-061-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a detailed inspection of the upper surface of the pylon spigot receptacle for damage or discontinuities. This inspection includes the fitting bore and the surface around the upper spar.
   (2) Make sure that there is no:
     (a) Corrosion damage:
- If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
5. Close-up
Subtask 54-51-00-420-062-A ** ON A/C NOT FOR ALL
A. Installation of the Spigot Ball Joint
   (1) Install the spigot ball joint (Ref. AMM TASK 54-51-41-400-001).
Subtask 54-51-00-410-061-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the pylon lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
     (a) For the left pylon: 415BL 415BR
     (b) For the right pylon: 425BL 425BR.
   (3) Install the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-002):
     (a) For the left pylon: 471AL 472AR
     (b) For the right pylon: 481AL 482AR.
Subtask 54-51-00-410-061-G ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the pylon lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
     (a) For the left pylon: 415BL 415BR
     (b) For the right pylon: 425BL 425BR.
   (3) Install the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-002):
     (a) For the left pylon: 471BL, 471BR
     (b) For the right pylon: 481BL, 481BR.
Subtask 54-51-00-440-059-A ** ON A/C NOT FOR ALL
C. Reactivation of the Thrust Reverser
   (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-51-00-440-059-B ** ON A/C NOT FOR ALL
C. Reactivation of the Thrust Reverser
   (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-012).
Subtask 54-51-00-942-089-A ** ON A/C NOT FOR ALL
D. Aircraft Maintenance Configuration
   (1) Remove the access platform(s).
   (2) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 01:59:34 UTC