W DOC AIRBUS | AMM A320F

Removal of the Pylon-to-Wing Access Panels


TASK 54-53-11-000-002-A
Removal of the Pylon-to-Wing Access Panels


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 470
ZONE: 480
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
470
ENGINE 1 AFT PYLON
480
ENGINE 2 AFT PYLON
414FR, 423FL, 471AL, 471BL, 471CL, 472AR, 472BR, 475AL, 475BL, 475CL, 476AR, 476BR, 476CR, 477AL, 481AL, 481BL, 482AR, 482BR, 482CR, 485AL, 485BL, 485CL, 486AR, 486BR, 486CR, 487AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
3. Job Set-up
Subtask 54-53-11-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to start engine 1(2).
   (2) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 54-53-11-010-057-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position :
     (a) For the left pylon, in zone 470
     (b) For the right pylon, in zone 480.
Subtask 54-53-11-040-057-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
4. Procedure
Subtask 54-53-11-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the Pylon-to-Wing Access Panels
F Pylon-to-Wing Access Panels ** ON A/C NOT FOR ALL
NOTE: The procedure is the same for all the panels:
   (1) Remove the screws (3) and the washers (2).
   (2) Remove the pylon-to-wing access panel (1).
[Rev.10 from 2021] 2026.04.01 02:02:26 UTC