W DOC AIRBUS | AMM A320F

Make the Thrust Reverser Serviceable after Maintenance [CFMB]


TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance


ZONE: 400
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
HIX3008
1
LOCK-OUT PIN
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-31-00-710-042-A
Operational Test of the Thrust Reverser System
TASK 78-31-00-710-043-A
Operational Test of the Thrust Reverser without CFDS - Engine Not Running
TASK 78-31-00-710-043-A-01
Operational Test of the Thrust Reverser without CFDS - Engine Running
3. Job Set-up
Subtask 78-30-00-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 78-30-00-010-056-A ** ON A/C NOT FOR ALL
B. Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 78-30-00-440-053-A ** ON A/C NOT FOR ALL
A. Make the Thrust Reverser Serviceable after Maintenance
   (1) Remove the HIX3008 LOCK-OUT PIN from the HCU lever OFF position (see sheet.2).
   (2) Move the HCU lever aft to make the thrust reverser serviceable (see sheet.1).
NOTE: The quick-release pin is NOT used in this procedure.
5. Close-up
Subtask 78-30-00-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 78-30-00-710-075-A ** ON A/C NOT FOR ALL
B. Operational Test
   (1) Do an operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-042).
NOTE: As an alternative procedure you can do this operational test without the Centralized Fault Display System (CFDS):
[Rev.10 from 2021] 2026.04.01 03:23:47 UTC