Make the Thrust Reverser Serviceable after Maintenance [CFMB]
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-30-00-860-050-A ** ON A/C NOT FOR ALL
Subtask 78-30-00-440-053-A ** ON A/C NOT FOR ALL
Subtask 78-30-00-410-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:23:47 UTC
Make the Thrust Reverser Serviceable after Maintenance
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| HIX3008 | 1 | LOCK-OUT PIN |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-31-00-710-042-A | Operational Test of the Thrust Reverser System |
| TASK 78-31-00-710-043-A | Operational Test of the Thrust Reverser without CFDS - Engine Not Running |
| TASK 78-31-00-710-043-A-01 | Operational Test of the Thrust Reverser without CFDS - Engine Running |
Subtask 78-30-00-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 78-30-00-010-056-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
B. Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 78-30-00-440-053-A ** ON A/C NOT FOR ALL
A. Make the Thrust Reverser Serviceable after Maintenance
(1) Remove the HIX3008 LOCK-OUT PIN from the HCU lever OFF position (see sheet.2).
(2) Move the HCU lever aft to make the thrust reverser serviceable (see sheet.1).
5. Close-up(1) Remove the HIX3008 LOCK-OUT PIN from the HCU lever OFF position (see sheet.2).
(2) Move the HCU lever aft to make the thrust reverser serviceable (see sheet.1).
NOTE: The quick-release pin is NOT used in this procedure.
Subtask 78-30-00-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 78-30-00-710-075-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
B. Operational Test
(1) Do an operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-042).
(1) Do an operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-042).
NOTE: As an alternative procedure you can do this operational test without the Centralized Fault Display System (CFDS):
- First method with engine not running (Ref. AMM TASK 78-31-00-710-043)
- Second method with engine running (Ref. AMM TASK 78-31-00-710-043).
Lock-out pin (HIX 3008) Installation/Removal (for maintenance)