1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
470
ENGINE 1 AFT PYLON
480
ENGINE 2 AFT PYLON
471AL, 471AR, 471BL, 471BR, 471CL, 471CR, 471DL, 475AL, 475AR, 475BL, 475BR, 477AL, 481AL, 481AR, 481BL, 481BR, 481CL, 481CR, 481DR, 485AL, 485AR, 485BL, 485BR, 487AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 20-28-00-912-802-A
Electrical Bonding - General Maintenance Procedure
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
F Pylon-to-Wing Access Panels ** ON A/C NOT FOR ALL
F Pylon-to-Wing Access Panels ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 54-53-11-869-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that a WARNING NOTICE(S) is in position in the cockpit to tell persons not to start engine 1(2).
   (2) On overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
     (a) For the left pylon, in zone 470
     (b) For the right pylon, in zone 480.
Subtask 54-53-11-040-069-A ** ON A/C NOT FOR ALL
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make sure that the thrust reverser is unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-53-11-040-069-B ** ON A/C NOT FOR ALL
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make sure that the thrust reverser is unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-012).
4. Procedure
Subtask 54-53-11-420-055-A ** ON A/C NOT FOR ALL
CAUTION: MAKE SURE THAT THE SEALS OF THE ACCESS PANELS ARE IN THE CORRECT POSITION BELOW THE WING LOWER SURFACE. YOU CAN CAUSE DAMAGE TO THE SEALS IF THEY ARE NOT IN THE CORRECT POSITION.
A. Installation of the Pylon-to-Wing Access Panels
F Pylon-to-Wing Access Panels ** ON A/C NOT FOR ALL
NOTE: The procedure is the same for all the panels:
   (1) Put the pylon-to-wing access panel (1) in position.
   (2) Make sure that the applicable seal is correctly installed in the pylon-to-wing access panel groove.
   (3) Install the washers (2) and the screws (3) and tighten them.
   (4) When you install the screws (3), do the electrical bonding at the applicable location (Ref. AMM TASK 20-28-00-912-802).
NOTE: For the electrical bonding location, refer to the related figure.
Subtask 54-53-11-420-055-B ** ON A/C NOT FOR ALL
CAUTION: MAKE SURE THAT THE SEALS OF THE ACCESS PANELS ARE IN THE CORRECT POSITION BELOW THE WING LOWER SURFACE. YOU CAN CAUSE DAMAGE TO THE SEALS IF THEY ARE NOT IN THE CORRECT POSITION.
A. Installation of the Pylon-to-Wing Access Panels
F Pylon-to-Wing Access Panels ** ON A/C NOT FOR ALL
NOTE: The procedure is the same for all the panels:
   (1) Put the pylon-to-wing access panel (1) in position.
   (2) Make sure that the applicable seal is correctly installed in the pylon-to-wing access panel groove.
   (3) Install the washers (2) and the screws (3) and tighten them.
   (4) When you install the screws (3), do the electrical bonding at the applicable location (Ref. AMM TASK 20-28-00-912-802).
NOTE: For the electrical bonding location, refer to the related figure.
5. Close-up
Subtask 54-53-11-440-057-A ** ON A/C NOT FOR ALL
A. Reactivation of the Thrust Reverser
   (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-53-11-440-057-B ** ON A/C NOT FOR ALL
A. Reactivation of the Thrust Reverser
   (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-012).
Subtask 54-53-11-942-056-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).