Installation of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-A
Installation of the Pylon-to-Wing Access Panels
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-53-11-869-055-A ** ON A/C NOT FOR ALL
Subtask 54-53-11-420-054-A ** ON A/C NOT FOR ALL
(2) Make sure that the applicable seal is correctly installed in the pylon-to-wing access panel groove.
(3) Install the washers (2) and the screws (3) and tighten them.
(4) When you install the screws (3), do the electrical bonding at the applicable location (Ref. AMM TASK 20-28-00-912-802).
5. Close-up
Subtask 54-53-11-440-056-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:02:28 UTC
Installation of the Pylon-to-Wing Access Panels
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| 414FR, 423FL, 471AL, 471BL, 471CL, 472AR, 472BR, 475AL, 475BL, 475CL, 476AR, 476BR, 476CR, 477AL, 481AL, 481BL, 482AR, 482BR, 482CR, 485AL, 485BL, 485CL, 486AR, 486BR, 486CR, 487AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
Subtask 54-53-11-869-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that a WARNING NOTICE(S) is in position in the cockpit to tell persons not to start engine 1(2).
(2) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
Subtask 54-53-11-040-067-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that a WARNING NOTICE(S) is in position in the cockpit to tell persons not to start engine 1(2).
(2) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, in zone 470
(b) For the right pylon, in zone 480.
B. Deactivation of the Thrust Reverser
4. ProcedureWARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make sure that the thrust reverser is unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). Subtask 54-53-11-420-054-A ** ON A/C NOT FOR ALL
CAUTION:
MAKE SURE THAT THE SEALS OF THE ACCESS PANELS ARE IN THE CORRECT POSITION BELOW THE WING LOWER SURFACE.
YOU CAN CAUSE DAMAGE TO THE SEALS IF THEY ARE NOT IN THE CORRECT POSITION.
A. Installation of the Pylon-to-Wing Access Panels NOTE: The procedure is the same for all the panels:
(1) Put the pylon-to-wing access panel (1) in position. (2) Make sure that the applicable seal is correctly installed in the pylon-to-wing access panel groove.
(3) Install the washers (2) and the screws (3) and tighten them.
(4) When you install the screws (3), do the electrical bonding at the applicable location (Ref. AMM TASK 20-28-00-912-802).
NOTE: For the electrical bonding location, refer to the related figure.
Subtask 54-53-11-440-056-A ** ON A/C NOT FOR ALL
A. Reactivation of the Thrust Reverser
(1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-53-11-942-055-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Pylon-to-Wing Access Panels