W DOC AIRBUS | AMM A320F

Installation of the Temperature Transmitter


TASK 29-33-11-400-002-A
Installation of the Temperature Transmitter


WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 2381GR
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER - HYDRAULIC FLUID RESISTANT
No specific
2
WARNING NOTICE(S)
No specific
Torque wrench: range to between 4.5 and 4.0 m.daN (33.19 and 29.50 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02ABA1)
Phosphate Ester Hydraulic Fluid-General Power - -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
197FB
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
O-RING
AIPC 29-33-04-01-060
3
O-RING
AIPC 29-33-84-01-060
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 20-28-00-912-802-A
Electrical Bonding - General Maintenance Procedure
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-10-00-863-003-A
Pressurize the Blue Hydraulic System with a Hydraulic Ground Power-Cart
TASK 29-10-00-863-003-A-01
Pressurize the Blue Hydraulic System with the Blue Electric Pump
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 29-33-11-860-060-A
A. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
   (3) Make sure that the reservoir of the Blue hydraulic system is depressurized.
(Ref. AMM TASK 29-14-00-614-001).
   (4) Make sure that the WARNING NOTICE(S) are in position:
  • In the cockpit on the hydraulic section 40VU of the overhead panel,
  • On the ground service panel of the Blue hydraulic system.
   (5) Make sure that the access panel 197FB is open.
   (6) Make sure that the CONTAINER - HYDRAULIC FLUID RESISTANT is in position below the location of the temperature transmitter.
Subtask 29-33-11-865-057-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
123VUB HYD/ELEC PUMP2701GJAB09
4. Procedure
Subtask 29-33-11-420-051-A
A. Installation of the Temperature Transmitter
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the blanking plugs from the ports of the filter head (4).
   (4) Lubricate the new AIPC 29-33-04-01-060 O-RING (3) or AIPC 29-33-84-01-060 O-RING (3) with Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) .
   (5) Put the new O-ring (3) in position on the temperature transmitter (2).
   (6) Install the temperature transmitter (2) to the filter head (4).
   (7) TORQUE the temperature transmitter (2) to between 4.5 and 4.0 m.daN (33.19 and 29.50 lbf.ft ) T.
   (8) Install the bonding jumper (7) together with the washer (6) and the nut (5) (
Ref. AMM TASK 20-28-00-912-802).
   (9) Remove the blanking cap from the electrical connector (1).
   (10) Make sure that all the electrical connections are clean and in the correct condition.
   (11) Connect the electrical connector (1).
Subtask 29-33-11-865-053-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
123VUB HYD/ELEC PUMP2701GJAB09
Subtask 29-33-11-790-051-A
C. Leak Test of the Hydraulic Connections
   (1) Remove the warning notices from the ground service panel and from the overhead panel.
   (2) Pressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-002).
   (3) Pressurize the Blue hydraulic system (Ref. AMM TASK 29-10-00-863-003).
   (4) Examine the temperature transmitter connection and make sure that there are no leaks.
Subtask 29-33-11-860-053-A
D. Test of the Temperature Transmitter
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (3) On the ECAM control panel on the center pedestal push the HYD pushbutton. Make sure the the HYD page on the system (lower) display comes on.
   (4) Make sure that the ECAM system shows no overtemperature.
   (5) Depressurize the Blue hydraulic system (Ref. AMM TASK 29-10-00-864-003).
5. Close-up
Subtask 29-33-11-860-059-A
A. Put the aircraft back to the serviceable condition.
   (1) Make sure that the fluid level in the reservoir of the Blue hydraulic system is correct. Add fluid as necessary (Ref. AMM TASK 12-12-29-611-001).
   (2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
   (4) Remove the container from below the temperature transmitter.
   (5) Make sure that the work area is clean and clear of tools and other items.
   (6) Close the access panel 197FB.
[Rev.10 from 2021] 2026.04.01 08:03:21 UTC