W DOC AIRBUS | AMM A320F

Depressurization of the Hydraulic Reservoirs


TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
FIN: 1000GQ
FIN: 2000GQ
FIN: 3000GQ
1. Reason for the Job
To depressurize the hydraulic reservoirs for maintenance.
NOTE: You can depressurize each hydraulic reservoir independently.
NOTE: Two procedures are available to depressurize the hydraulic reservoirs, one procedure uses ground equipment, the other does not. Do one of the two procedures.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
97A29102062000
2
CONNECTOR - DEPRESSURIZING, HYDRAULIC RESERVOIR
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
196BB, 197CB, 197EB, 197FB, 198CB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 29-14-00-010-050-A
A. Get Access
   (1) Open the applicable access panels and doors:
     (a) For the Green hydraulic system:
     (b) For the Blue hydraulic system:
     (c) For the Yellow hydraulic system:
Subtask 29-14-00-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
4. Procedure
Subtask 29-14-00-614-051-A
A. Depressurization with Ground Equipment
   (1) Put a container in position to collect any fluid which may come out of the depressurization valve.
   (2) Remove the depressurization valve-cap assembly from the depressurization valve and connect the 97A29102062000 CONNECTOR - DEPRESSURIZING, HYDRAULIC RESERVOIR.
   (3) Listen to hear if all of the air has been released.
NOTE: Keep the depressurization equipment connected if it is necessary to depressurize a reservoir for a maintenance operation. This prevents accidental pressurization of the reservoir. The depressurization equipment is removed when the maintenance operation is completed.
Subtask 29-14-00-614-053-A
B. Depressurization without Ground Equipment
WARNING: DO THE MAINTENANCE TASK IMMEDIATELY AFTER YOU DEPRESSURIZE THE RESERVOIR. IF THE AMBIENT TEMPERATURE INCREASES BETWEEN THE TIME YOU DEPRESSURIZE THE RESERVOIR AND THE TIME YOU DO THE WORK:
  • THE PRESSURE OF THE AIR IN THE RESERVOIR WILL INCREASE AGAIN,
AND
  • THERE IS RISK OF INJURY WHEN YOU OPEN THE SYSTEM.
WARNING: PROTECT YOUR HANDS AND FACE FROM THE GAS WHICH COMES OUT WHEN YOU OPEN THE MANUAL DEPRESSURIZATION VALVE OF THE RESERVOIRS. IT IS POSSIBLE THAT THE GAS IS HOT AND CONTAINS HYDRAULIC FLUID.
   (1) On the applicable ground service panel, turn the cap assembly of the reservoir depressurization valve (1087GM, 2087GM or 3087GM) clockwise through 90 degrees.
   (2) Hold the cap in the OPEN position. Do this until the applicable reservoir is depressurized.
   (3) Make sure that there is no pressure indication on the gage of the applicable reservoir.
5. Close-up
Subtask 29-14-00-860-054-A
A. Put the system back to the serviceable condition.
   (1) Remove the 97A29102062000 CONNECTOR - DEPRESSURIZING, HYDRAULIC RESERVOIR and connect the depressurization valve-cap assembly to the depressurization valve.
   (2) Turn the depressurization valve to CLOSED position.
   (3) Remove the container from below the depressurization valve.
Subtask 29-14-00-865-076-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-14-00-410-064-A
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the applicable access panels and doors:
     (a) For the Green hydraulic system:
     (b) For the Blue hydraulic system:
     (c) For the Yellow hydraulic system:
[Rev.10 from 2021] 2026.04.01 00:24:05 UTC