Installation of the Yellow HCU Pipe
TASK 29-13-49-400-049-A
Installation of the Yellow HCU Pipe
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 29-13-49-860-107-B ** ON A/C NOT FOR ALL
Subtask 29-13-49-420-098-B ** ON A/C NOT FOR ALL
Subtask 29-13-49-410-094-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:22:46 UTC
Installation of the Yellow HCU Pipe
WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
DO NOT GET HYDRAULIC FLUID ON YOUR SKIN, IN YOUR EYES OR IN YOUR MOUTH. HYDRAULIC FLUID IS POISONOUS AND CAN GO THROUGH YOUR SKIN AND INTO YOUR BODY. FLUSH HYDRAULIC FLUID FROM YOUR EYES, MOUTH OR SKIN WITH WATER. GET MEDICAL AID IF YOU GET HYDRAULIC FLUID IN YOUR EYES OR MOUTH.
CAUTION:
DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. IF YOU DO NOT USE THE SECOND WRENCH, THERE IS A RISK THAT YOU WILL LOOSEN OR TIGHTEN THE UNION TOO MUCH.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 195BB | |
| FOR [1000EM2] (ENGINE-2) | |
| 423AL, 447AL, 448AR, 461AL, 462AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 18 | NUT | AIPC 29-13-06-02-230 |
| 19 | NUT | AIPC 29-13-06-02-230 |
| 1 | NUTS | AIPC 54-57-17-04-020 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 26-21-49-000-002-A | Removal of the Engine Fire-Extinguishing Pipe |
| TASK 26-21-49-400-002-A | Installation of the Engine Fire-Extinguishing Pipe |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-13-00-710-002-A | Operational Test of the Yellow Hydraulic System |
| TASK 29-13-49-000-009-A | Removal of the Engine 2 Thrust-Reverser Hydraulic-Supply Hoses |
| TASK 29-13-49-400-009-A | Installation of the Engine 2 Thrust-Reverser Hydraulic-Supply Hoses |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 29-14-00-614-002-A | Pressurization of the Hydraulic Reservoirs through the Ground Connector |
| TASK 29-14-00-614-002-A-01 | Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU) |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 71-13-11-000-041-A | Removal of the Fan Cowl Doors |
| TASK 71-13-11-400-041-A | Installation of the Fan Cowl Doors |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-00-710-042-A | Operational Test of the Thrust Reverser System |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
| TASK 78-37-51-000-004-A | Removal of the Thrust Reverser Hydraulic Filter Assembly |
| TASK 78-37-51-400-004-A | Installation of the Thrust Reverser Hydraulic Filter Assembly |
Subtask 29-13-49-860-107-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the engine 2 shutdown occurred not less than five minutes before you do this procedure.
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
(4) Make sure that the reservoir of the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-14-00-614-001).
(5) On AIR COND panel 30VU:
(8) On the center pedestal, on ENG panel 115VU:
Subtask 29-13-49-865-094-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 2 shutdown occurred not less than five minutes before you do this procedure.
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-10-00-864-002).
(4) Make sure that the reservoir of the Yellow hydraulic system is depressurized (Ref. AMM TASK 29-14-00-614-001).
(5) On AIR COND panel 30VU:
- Make sure that the APU BLEED pushbutton switch is released (the ON legend off).
- Make sure that a WARNING NOTICE(S) is in position to tell persons not to operate this pushbutton switch.
- On the HYD section of overhead panel 40VU
- On the ground service panel 198CB.
(8) On the center pedestal, on ENG panel 115VU:
- Make sure that the ENG/MODE selector switch is in the NORM position.
- Make sure that the ENG/MASTER 2 control switch was in the OFF position not less than five minutes before you do this procedure.
- Make sure that WARNING NOTICE(S) is in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 2 control switch.
- Make sure that the ON legend of the ENG FADEC GND PWR/2 pushbutton switch is off.
- Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 2.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 29-13-49-010-099-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
C. Get Access
(1) Make sure that this access panel is removed:
(a) FOR [1000EM2] (ENGINE-2)
423AL.
(2) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(3) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
(4) Make sure that an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at the zone 420.
(5) Make sure that a CONTAINER 5 L (1.32 USGAL) is in position below the hydraulic lines.
Subtask 29-13-49-040-065-B ** ON A/C NOT FOR ALL (1) Make sure that this access panel is removed:
(a) FOR [1000EM2] (ENGINE-2)
423AL.
(2) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(3) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
(4) Make sure that an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at the zone 420.
(5) Make sure that a CONTAINER 5 L (1.32 USGAL) is in position below the hydraulic lines.
D. Deactivation of the Thrust Reverser
Subtask 29-13-49-020-107-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make sure that the thrust reverser is unserviceable (Ref. AMM TASK 78-30-00-481-041). E. Maintenance Configuration for the Access to the Yellow HCU Pipe
(1) Make sure that the left fan-cowl door is removed (Ref. AMM TASK 71-13-11-000-041).
(2) Make sure that the thrust-reverser hydraulic-supply hoses are disconnected (Ref. AMM TASK 29-13-49-000-009).
(a) Make sure that the four hoses are disconnected from the left interface bracket.
(b) Make sure that the hose is disconnected from the pylon tube at the left bracket.
(c) Make sure that the clamps that hold the five disconnected hoses are released.
(d) Make sure that the hoses are pushed into the pylon.
(3) Make sure that the left and the right support plates are released.
(4) Make sure that the two FWD parts of the engine fire-extinguishing pipe are disconnected and are on the fan case (Ref. AMM TASK 26-21-49-000-002).
(5) Make sure that the return pipe (27) and the control pipe (7) are removed.
(6) Make sure that the thrust-reverser hydraulic filter-assembly is removed (Ref. AMM TASK 78-37-51-000-004).
4. Procedure(1) Make sure that the left fan-cowl door is removed (Ref. AMM TASK 71-13-11-000-041).
(2) Make sure that the thrust-reverser hydraulic-supply hoses are disconnected (Ref. AMM TASK 29-13-49-000-009).
(a) Make sure that the four hoses are disconnected from the left interface bracket.
(b) Make sure that the hose is disconnected from the pylon tube at the left bracket.
(c) Make sure that the clamps that hold the five disconnected hoses are released.
(d) Make sure that the hoses are pushed into the pylon.
(3) Make sure that the left and the right support plates are released.
(4) Make sure that the two FWD parts of the engine fire-extinguishing pipe are disconnected and are on the fan case (Ref. AMM TASK 26-21-49-000-002).
(5) Make sure that the return pipe (27) and the control pipe (7) are removed.
(6) Make sure that the thrust-reverser hydraulic filter-assembly is removed (Ref. AMM TASK 78-37-51-000-004).
Subtask 29-13-49-420-098-B ** ON A/C NOT FOR ALL
A. Installation of the Yellow HCU Pipe
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the PLUG-BLANKING from each disconnected line end.
(4) Put the HCU pipe (14) in position on the pylon.
(5) Connect the HCU pipe (14) to the pressure pipe (32).
(6) Attach the clamp (15) with the washer (16) and the bolt (17).
(7) Tighten the bolt (17).
.
Subtask 29-13-49-420-098-C ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the PLUG-BLANKING from each disconnected line end.
(4) Put the HCU pipe (14) in position on the pylon.
(5) Connect the HCU pipe (14) to the pressure pipe (32).
(6) Attach the clamp (15) with the washer (16) and the bolt (17).
(7) Tighten the bolt (17).
NOTE: The clamp (13) is attached with the washer (16) and the bolt (17) in step 4.B.(1).
(8) TORQUE the nut (6) to between 5.9 and 5.4 m.daN (43.51 and 39.82 lbf.ft )
. NOTE: The nut (12) is connected to the hydraulic filter canister (11) in the step 4.B.(1).
A. Installation of the Yellow HCU Pipe
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the PLUG-BLANKING from each disconnected line end.
(4) Put the HCU pipe (14) in position on the pylon.
(5) Connect the HCU pipe (14) to the pressure pipe (32).
(6) Attach the clamps (15) with the washers (16) and the bolts (17).
(7) Tighten the bolts (17).
.
Subtask 29-13-49-420-099-D ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the PLUG-BLANKING from each disconnected line end.
(4) Put the HCU pipe (14) in position on the pylon.
(5) Connect the HCU pipe (14) to the pressure pipe (32).
(6) Attach the clamps (15) with the washers (16) and the bolts (17).
(7) Tighten the bolts (17).
NOTE: The clamp (13) is attached with the washer (16) and the bolt (17) in step 4.B.(1).
(8) TORQUE the nut (6) to between 5.9 and 5.4 m.daN (43.51 and 39.82 lbf.ft )
. NOTE: The nut (12) is connected to the hydraulic filter canister (11) in the step 4.B.(1).
B. Close Access after the Installation of the Yellow HCU Pipe
(1) Install the thrust-reverser hydraulic filter-assembly (Ref. AMM TASK 78-37-51-400-004).
(a) Put the control pipe (7) in position in the pylon.
(b) Install the bolts (4), the washers (3) on the union (5) and tighten.
(c) Remove the PLUG-BLANKING from each disconnected line end.
(d) Connect the nut (2) to the union (5).
(e) Connect the control pipe (7) to the thrust-reverser hydraulic isolation-valve (33).
(f) Attach the clamp (25) to the support (26) with the bolt (24), the washer (23) and the new AIPC 29-13-06-02-230 NUT (19) and tighten.
(g) Attach the clamp (10) with the bolt (8) and the washer (9) and tighten.
(h) TORQUE the nut (2) to between 5.9 and 5.4 m.daN (43.51 and 39.82 lbf.ft )
.
(i) TORQUE the nut (34) to between 3.2 and 2.9 m.daN (23.60 and 21.39 lbf.ft )
.
(3) Install the return pipe.
(a) Put the return pipe (27) in position in the pylon.
(b) Remove the PLUG-BLANKING from each disconnected line end.
(c) Connect the return pipe (27) to the case drain pipe (1).
(d) Connect the return pipe (27) to the thrust-reverser hydraulic isolation-valve (33).
(e) Attach the clamp (20) to the support (26) with the bolt (21), the washer (22) and the new AIPC 29-13-06-02-230 NUT (18) and tighten.
(f) Attach the clamp (30) with the bolt (28) and the washer (29) and tighten.
(g) TORQUE the nut (31) to between 4.57 and 4.47 m.daN (33.70 and 32.96 lbf.ft )
.
(h) TORQUE the nut (35) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
.
(4) Connect the two FWD parts of the engine fire-extinguishing pipe (Ref. AMM TASK 26-21-49-400-002).
(a) Connect the two FWD parts of the engine fire-extinguishing pipe to the pipe installed in the pylon and tighten (Ref. AMM TASK 26-21-49-400-002).
(b) Install the bolts, the washers and the nuts that attach the two FWD parts of the pipe and tighten.
(5) In the pylon, attach the left and the right support plates (5) to the structure (4).
(a) Install the bolts (3), the washers (2), and the new AIPC 54-57-17-04-020 NUTS (1) and tighten.
(6) Connect the thrust-reverser hydraulic-supply hoses (Ref. AMM TASK 29-13-49-400-009).
(a) At the left bracket, connect the hose to the pylon tube and tighten it (Ref. AMM TASK 29-13-49-400-009).
(b) Connect the four hoses to the left interface bracket and tighten them (Ref. AMM TASK 29-13-49-400-009).
(c) Put in position the clamps that hold the hoses.
(7) Connect the electrical connector to the thrust-reverser hydraulic isolation-valve.
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Make sure that all the electrical connections are clean and in the correct condition.
(c) Connect the electrical connector (36) to the isolation valve (33).
(8) Install the left fan-cowl door (Ref. AMM TASK 71-13-11-400-041).
Subtask 29-13-49-410-092-B ** ON A/C NOT FOR ALL (1) Install the thrust-reverser hydraulic filter-assembly (Ref. AMM TASK 78-37-51-400-004).
NOTE: The electrical connector connection to the isolation valve is not applicable in this step.
(2) Install the control pipe. (a) Put the control pipe (7) in position in the pylon.
(b) Install the bolts (4), the washers (3) on the union (5) and tighten.
(c) Remove the PLUG-BLANKING from each disconnected line end.
(d) Connect the nut (2) to the union (5).
(e) Connect the control pipe (7) to the thrust-reverser hydraulic isolation-valve (33).
(f) Attach the clamp (25) to the support (26) with the bolt (24), the washer (23) and the new AIPC 29-13-06-02-230 NUT (19) and tighten.
(g) Attach the clamp (10) with the bolt (8) and the washer (9) and tighten.
(h) TORQUE the nut (2) to between 5.9 and 5.4 m.daN (43.51 and 39.82 lbf.ft )
. (i) TORQUE the nut (34) to between 3.2 and 2.9 m.daN (23.60 and 21.39 lbf.ft )
. (3) Install the return pipe.
(a) Put the return pipe (27) in position in the pylon.
(b) Remove the PLUG-BLANKING from each disconnected line end.
(c) Connect the return pipe (27) to the case drain pipe (1).
(d) Connect the return pipe (27) to the thrust-reverser hydraulic isolation-valve (33).
(e) Attach the clamp (20) to the support (26) with the bolt (21), the washer (22) and the new AIPC 29-13-06-02-230 NUT (18) and tighten.
(f) Attach the clamp (30) with the bolt (28) and the washer (29) and tighten.
(g) TORQUE the nut (31) to between 4.57 and 4.47 m.daN (33.70 and 32.96 lbf.ft )
. (h) TORQUE the nut (35) to between 1.7 and 1.5 m.daN (12.54 and 11.06 lbf.ft )
. (4) Connect the two FWD parts of the engine fire-extinguishing pipe (Ref. AMM TASK 26-21-49-400-002).
(a) Connect the two FWD parts of the engine fire-extinguishing pipe to the pipe installed in the pylon and tighten (Ref. AMM TASK 26-21-49-400-002).
(b) Install the bolts, the washers and the nuts that attach the two FWD parts of the pipe and tighten.
(5) In the pylon, attach the left and the right support plates (5) to the structure (4).
(a) Install the bolts (3), the washers (2), and the new AIPC 54-57-17-04-020 NUTS (1) and tighten.
(6) Connect the thrust-reverser hydraulic-supply hoses (Ref. AMM TASK 29-13-49-400-009).
(a) At the left bracket, connect the hose to the pylon tube and tighten it (Ref. AMM TASK 29-13-49-400-009).
(b) Connect the four hoses to the left interface bracket and tighten them (Ref. AMM TASK 29-13-49-400-009).
(c) Put in position the clamps that hold the hoses.
(7) Connect the electrical connector to the thrust-reverser hydraulic isolation-valve.
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
(b) Make sure that all the electrical connections are clean and in the correct condition.
(c) Connect the electrical connector (36) to the isolation valve (33).
(8) Install the left fan-cowl door (Ref. AMM TASK 71-13-11-400-041).
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the container.
(3) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 29-13-49-440-057-B ** ON A/C NOT FOR ALL Subtask 29-13-49-865-095-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the container.
(3) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 29-13-49-614-051-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
F. Pressurization of the Hydraulic Reservoir
(1) Pressurize the Yellow hydraulic reservoir of the engine 2 (Ref. AMM TASK 29-14-00-614-002).
Subtask 29-13-49-710-075-B ** ON A/C NOT FOR ALL (1) Pressurize the Yellow hydraulic reservoir of the engine 2 (Ref. AMM TASK 29-14-00-614-002).
G. Operational Tests
(1) Do the operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
(2) Operate the thrust reverser for ten deploy-to-stow cycles (Ref. AMM TASK 78-31-00-710-042).
(a) Make sure that the TEST OK indication comes into view on the MCDU.
(3) Make sure that there are no leaks at the tube connections.
5. Close-up(1) Do the operational test of the Yellow hydraulic system (Ref. AMM TASK 29-13-00-710-002).
(2) Operate the thrust reverser for ten deploy-to-stow cycles (Ref. AMM TASK 78-31-00-710-042).
(a) Make sure that the TEST OK indication comes into view on the MCDU.
(3) Make sure that there are no leaks at the tube connections.
Subtask 29-13-49-410-094-B ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(3) Install the access panel:
(a) FOR [1000EM2] (ENGINE-2)
423AL.
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
Subtask 29-13-49-862-057-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(3) Install the access panel:
(a) FOR [1000EM2] (ENGINE-2)
423AL.
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).