27-51 FLAPS ELECTRICAL CONTROL AND MONITORING
- PB.201 FLAPS ELECTRICAL CONTROL AND MONITORING - FAULT ISOLATION PROCEDURES
-
27-51-00-810-802-A
[8]
SFCC - FLAP PCU VALVEBLOCK Fault -
27-51-00-810-803-A
[8]
FLP APPU LH/RH or SFCC Interface Fault -
27-51-00-810-804-A
[8]
FLP FPPU or SFCC Interface Fault -
27-51-00-810-805-A
[8]
CSU Fault (51CV) or Fault in Wiring to SFCC 1 (2) -
27-51-00-810-806-A
[8]
Data Fault Between SFCC 1 and SFCC 2. Loss of Cross-computer Link or Faulty Data -
27-51-00-810-807-A
[8]
Loss of SFCC 1 (2) Because of an A/C Pin Program Fault -
27-51-00-810-808-A
[8]
FLP FPPU or Wiring Fault -
27-51-00-810-809-A
[8]
FLP APPU LH/RH Fault or Wiring Fault -
27-51-00-810-810-A
[8]
Flap System Jam -
27-51-00-810-811-A
[8]
CSU Sensor Out of Adjustment (Sensor out of valid region) No WTB Set -
27-51-00-810-812-A
[8]
SFCC 1 (2) OR FLP PPU POWER SFCC Generated FLAP PPU Power Fault -
27-51-00-810-814-A
[8]
FLAP SYSTEM 1 (2) FAULT, No CFDS Message (normal mode) -
27-51-00-810-815-A
[8]
FLAP SYSTEM 1 (2) Fault With a FLAP SYSTEM 2 (1) FAULT and Both CFDS Message Are Not the Same -
27-51-00-810-817-A
[8]
Left Flap Interconnecting-Strut Attachment Failure-Detection Sensor Fault -
27-51-00-810-818-A
[8]
Flap Alignment Fault -
27-51-00-810-819-A
[8]
Flap System Asymmetry Fault -
27-51-00-810-820-A
[8]
Flap System Runaway -
27-51-00-810-821-A
[8]
Right Flap Interconnecting-Strut Attachment Failure-Detection Sensor Fault -
27-51-00-810-825-A
[8]
Flap System Uncommanded Movement -
27-51-00-810-826-A
[8]
Half Speed Operation Detected -
27-51-00-810-828-A
[8]
Flaps Command Sensor Unit Failure -
27-51-00-810-830-A
[8]
SFCC 1 or 2 Shows a LH or RH Flap Attachment Proximity Sensor as a Misadjustment -
27-51-00-810-831-A
[8]
SFCC 1 No LGCIU 1 Data or SFCC 2 No LGCIU 2 Data -
27-51-00-810-832-A
[8]
SFCC 1 FLP 1 No ADIRU 1 Data or SFCC 2 FLP 2 No ADIRU 1 Data -
27-51-00-810-833-A
[8]
Flap Position Indication Disagree -
27-51-00-810-834-A
[8]
SFCC 1 FLP 1 no CFDIU Data or SFCC 2 FLP 2 no CFDIU Data, Fault Related to the SFCC Arinc Input -
27-51-00-810-835-A
[8]
Electrical Power to the FLP 1 WTB Monitored to Below 14VDC Electrical Power to the FLP 2 WTB Monitored to Below 14VDC -
27-51-00-810-836-A
[8]
FLP LH WTB BLU Solenoid 33CV or Open or Short Circuit to SFCC 1 FLP LH WTB YEL Solenoid 33CV or Open or Short Circuit to SFCC 2 -
27-51-00-810-837-A
[8]
FLP RH WTB BLU Solenoid 34CV or Open or Short Circuit to SFCC 1 FLP RH WTB GRN Solenoid 34CV or Open or Short Circuit to SFCC 2 -
27-51-00-810-839-A
[8]
EFCS Identifies a Loss of Data from the SFCC-1 (2) -
27-51-00-810-840-A
[8]
Flap Shaft Overspeed -
27-51-00-810-841-A
[8]
Wrong Inhibit Sign From Cargo Door Yellow System -
27-51-00-810-842-A
[8]
Flap SFCS Status Message -
27-51-00-810-843-A
[8]
Flap Flag Indication Does Not Agree With Flap Position -
27-51-00-810-844-A
[8]
Flap Menu Not Available On The CFDIU, Fault Related to the SFCC ARINC Output -
27-51-00-810-845-A
[8]
Flaps - SFCC Flap Channel Failure -
27-51-00-810-846-A
[8]
Flap Pin Program Disagree Installation Fault -
27-51-00-810-847-A
[8]
Standard of SFCC-1 and SFCC-2 Does Not Agree With Aicraft Type -
27-51-00-810-848-A
[8]
Flaps - Torque Limiter Tripped Without a Cockpit Effect -
27-51-00-810-849-A
[8]
Flaps - Flaps Locked at Aircraft Power-Up -
27-51-00-810-850-A
[8]
Flaps - SFCC TEST Gives the Message NO FAULTS BUT -
27-51-00-810-851-A
[8]
Flaps - SFCC 1 and SFCC 2 Show PCU Valveblock Fault Message -
27-51-00-810-852-A
[8]
Flaps - SFCC 1 (2) Gives PCU Valveblock 23CV (24CV) Valve Sensor Message -
27-51-00-810-853-A
[8]
Flap Attachment ECAM Warning (FLT/CTL - FLAP ATTACH SENSOR) -
27-51-00-810-854-A
[8]
SFCC Test Gives the Message PERFORMED WITH FAULT -
27-51-00-810-855-A
[8]
WTB/POB Test Performed Unsuccessfully or Test Aborted
-
27-51-00-810-802-A
[8]
- PB.301 FLAPS ELECTRICAL CONTROL AND MONITORING - TASK SUPPORTING DATA