SFCC - FLAP PCU VALVEBLOCK Fault
TASK 27-51-00-810-802-A
SFCC - FLAP PCU VALVEBLOCK Fault
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 27-51-00-710-051-A
Subtask 27-51-00-810-051-A
Subtask 27-51-00-942-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:36 UTC
SFCC - FLAP PCU VALVEBLOCK Fault
1. Possible Causes
- VALVE BLOCK-FLAP 1 [23CV]
- VALVE BLOCK-FLAP 2 [24CV]
- SOLENOID VALVE
- valveblock filters
- aircraft wiring
- SLAT/FLAP CONTR.COMP. [21CV]
- SLAT/FLAP CONTR.COMP. [22CV]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | MEGOHMMETER 100 MOHMS - MEASURING VOLTAGE 45 VDC |
| No specific | 1 | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-51-00-810-852-A | Flaps - SFCC 1 (2) Gives PCU Valveblock 23CV (24CV) Valve Sensor Message |
| AMM 27-50-00-866-008 | Extension of the Flaps on the Ground |
| AMM 27-50-00-866-009 | Retraction of the Flaps on the Ground |
| ASM 275102 | |
| ASM 275103 | |
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| AMM 27-54-53-000-001 | Removal of the Valve Blocks of the Power Control Unit (Flap) |
| AMM 27-54-53-000-002 | Removal of the Solenoid Valves of the Power Control Unit (Flap) |
| AMM 27-54-53-000-003 | Removal of the Filters of the Valve Blocks |
| AMM 27-54-53-400-001 | Installation of the Valve Blocks of the Power Control Unit (Flap) |
| AMM 27-54-53-400-002 | Installation of the Solenoid Valves of the Power Control Unit (Flap) |
| AMM 27-54-53-400-003 | Installation of the Filters of the Valve Blocks |
Subtask 27-51-00-710-051-A
A. Test
(1) Make sure that the Post Flight Report does not show hydraulic system faults.
(2) Move the flaps AMM 27-50-00-866-008 AMM 27-50-00-866-009.
(a) Examine the SFCC, FLP ON GROUND FAULTS page for a valveblock message.
(b) If a valveblock message is shown, or the A/C has had this fault before, do the fault isolation procedure.
(c) If the fault message FLP 1 (2) PCU VALVEBLOCK 23CV (24CV) VALVE SENSOR 27-54-53 message is shown, do the TSM Task (Ref. TSM TASK 27-51-00-810-852).
4. Fault Isolation(1) Make sure that the Post Flight Report does not show hydraulic system faults.
(2) Move the flaps AMM 27-50-00-866-008 AMM 27-50-00-866-009.
(a) Examine the SFCC, FLP ON GROUND FAULTS page for a valveblock message.
(b) If a valveblock message is shown, or the A/C has had this fault before, do the fault isolation procedure.
(c) If the fault message FLP 1 (2) PCU VALVEBLOCK 23CV (24CV) VALVE SENSOR 27-54-53 message is shown, do the TSM Task (Ref. TSM TASK 27-51-00-810-852).
Subtask 27-51-00-810-051-A
A. Procedure
AMM 27-54-53-000-001.
(b) Use a MULTIMETER - STANDARD to do a check of the resistance values at the connector. Make a note of the resistance values between:
1 For the EXTEND solenoid, connect the pins U and T together.
2 For the RETRACT solenoid, connect the pins J and H together.
3 Connect one test lead of the MEGOHMMETER 100 MOHMS - MEASURING VOLTAGE 45 VDC or a 50VDC +5VDC/-5VDC Isolation Tester to the pins UT or JH and the other test lead to pin G.
4 Supply a test signal for 5 seconds then read the resistance value shown.
5 The resistance value must be more than 100 Megohms.
(3) If a SOLENOID VALVE fails one of the two tests at Para. 4.A. step (2):
(a) Examine the valveblock filters , if neccesary clean/replace them AMM 27-54-53-000-003 and AMM 27-54-53-400-003.
(5) Move the flaps (Ref. Para. 3.A. step (2)). Operate the flaps many times during the operational test to bleed the air from the system.
(6) If the fault continues, replace the applicable VALVE BLOCK-FLAP 1 [23CV] or VALVE BLOCK-FLAP 2 [24CV] ,
AMM 27-54-53-000-001 and AMM 27-54-53-400-001.
(7) If the fault continues:
(a) Get access to the electrical connector at the applicable valveblock.
(b) Release the connector.
(c) Do a check of the aircraft wiring from the applicable SFCC ARINC tray interface to the valveblock electrical connector ASM 275102 or ASM 275103.
(d) If there is a fault, do the repair.
(8) If there are no faults, interchange SFCC 1 and SFCC 2,
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(a) Move the flaps (Ref. Para. 3.A. step (2)).
(b) If the fault does not move to the other SFCC:
1 Install the serviceable SFCC to its initial position.
2 Replace the unserviceable SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] .
3 Move the flaps (Ref. Para. 3.A. step (2)).
4 At the MCDU get access to the SFCC system status and make sure that a NO FAULTS message is shown.
5. Close-upCAUTION:
MAKE SURE THAT YOU DO NOT CAUSE A SHORT CIRCUIT IN THE WIRING TO THE SOLENOID VALVES. A SHORT CIRCUIT CAN CAUSE DAMAGE TO THE SFCC(S).
(1) Do a check of the PLR for FLAP 1 (2) PCU VALVEBLOCK 23CV (24CV) VALVE SENSOR 27-54-53 message. If the message shows, do the TSM Task (Ref. TSM TASK 27-51-00-810-852). NOTE: This message is not a CFDS Normal Mode message and shows only in SFCC reports.
(2) Do a check of the circuit resistance and circuit isolation of the extend and retract solenoid valves as follows: NOTE: A test is not available for the Linear Variable Differential Transducer (LVDT).
(a) Get access to the electrical connector at the applicable VALVE BLOCK-FLAP 1 [23CV] or VALVE BLOCK-FLAP 2 [24CV] , AMM 27-54-53-000-001.
(b) Use a MULTIMETER - STANDARD to do a check of the resistance values at the connector. Make a note of the resistance values between:
- For SFCC 1/ VALVE BLOCK-FLAP 1 [23CV] , (EXTEND) pins T and U, (RETRACT) pins J and H ASM 275102
- For SFCC 2/ VALVE BLOCK-FLAP 2 [24CV] , (EXTEND) pins T and U, (RETRACT) pins J and H ASM 275103.
- For solenoid valves with Part No. 667C0000-02, between 71 Ohms and 84 Ohms
- For solenoid valves with Part No. 903A0000-01, between 53 Ohms and 60 Ohms
- For solenoid valves with Part No. 1106A0000-01 or 1111A0000-01, between 53 Ohms and 60 Ohms
- For solenoid valves with Part No. 5751A0000-01, between 53 Ohms and 60 Ohms.
1 For the EXTEND solenoid, connect the pins U and T together.
2 For the RETRACT solenoid, connect the pins J and H together.
3 Connect one test lead of the MEGOHMMETER 100 MOHMS - MEASURING VOLTAGE 45 VDC or a 50VDC +5VDC/-5VDC Isolation Tester to the pins UT or JH and the other test lead to pin G.
4 Supply a test signal for 5 seconds then read the resistance value shown.
5 The resistance value must be more than 100 Megohms.
(3) If a SOLENOID VALVE fails one of the two tests at Para. 4.A. step (2):
- Replace the applicable solenoid valve
AMM 27-54-53-000-002 and AMM 27-54-53-400-002.
(a) Examine the valveblock filters , if neccesary clean/replace them AMM 27-54-53-000-003 and AMM 27-54-53-400-003.
(5) Move the flaps (Ref. Para. 3.A. step (2)). Operate the flaps many times during the operational test to bleed the air from the system.
(6) If the fault continues, replace the applicable VALVE BLOCK-FLAP 1 [23CV] or VALVE BLOCK-FLAP 2 [24CV] ,
AMM 27-54-53-000-001 and AMM 27-54-53-400-001.
(7) If the fault continues:
(a) Get access to the electrical connector at the applicable valveblock.
(b) Release the connector.
(c) Do a check of the aircraft wiring from the applicable SFCC ARINC tray interface to the valveblock electrical connector ASM 275102 or ASM 275103.
(d) If there is a fault, do the repair.
(8) If there are no faults, interchange SFCC 1 and SFCC 2,
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(a) Move the flaps (Ref. Para. 3.A. step (2)).
(b) If the fault does not move to the other SFCC:
- Install the SFCCs in their initial positions.
1 Install the serviceable SFCC to its initial position.
2 Replace the unserviceable SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] .
3 Move the flaps (Ref. Para. 3.A. step (2)).
4 At the MCDU get access to the SFCC system status and make sure that a NO FAULTS message is shown.
Subtask 27-51-00-942-051-A
A. Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 27-51-00-860-051-A B. Put the aircraft back to its initial configuration.