Flap Menu Not Available On The CFDIU, Fault Related to the SFCC ARINC Output
TASK 27-51-00-810-844-A
Flap Menu Not Available On The CFDIU, Fault Related to the SFCC ARINC Output
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-51-00-740-070-A
Subtask 27-51-00-810-095-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:40 UTC
Flap Menu Not Available On The CFDIU, Fault Related to the SFCC ARINC Output
1. Possible Causes
- SLAT/FLAP CONTR.COMP. [21CV]
- SLAT/FLAP CONTR.COMP. [22CV]
PROX SNSR R L/G EXT 20GA PROX SNSR L L/G EXT 21GA PROX SNSR R L/G EXT 22GA PROX SNSR L L/G EXT 23GA - RELAY-A/C ON GND [95CV]
- RELAY-A/C ON GND [97CV]
aircraft wiring, installation and pin program wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-51-00-810-846-A | Flap Pin Program Disagree Installation Fault |
| AMM 27-51-00-740-002 | BITE Test of the Slat and Flap Control Computers (Flap System) |
| ASM 275102 | |
| ASM 275103 | |
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
Subtask 27-51-00-740-070-A
A. Test
(1) Make sure that the Flap channel 1 (2) is on.
(2) Do a BITE test of the applicable SFCC AMM 27-51-00-740-002.
4. Fault Isolation(1) Make sure that the Flap channel 1 (2) is on.
(2) Do a BITE test of the applicable SFCC AMM 27-51-00-740-002.
Subtask 27-51-00-810-095-A
A. Procedure
(1) If the flap menu is not available:
1 Put the serviceable SFCC back in its initial position.
2 Replace the unserviceable SFCC.
(b) If the fault does not move to the other SFCC:
(4) If the fault continues:
(a) Interchange the RELAY-A/C ON GND [95CV] with the RELAY-A/C ON GND [97CV] .
(b) Do the test in Para. 3.A. on the SFCC 1 and SFCC 2.
(c) If the fault moves to the other system, replace the relay in the system that has the fault.
(d) Do the test in Para. 3.A.
(5) If the fault does not move to the other system, do a check of theaircraft wiring, installation and pin program wiring :
(b) Do the test in Para. 3.A.
(6) If the fault continues, make sure that no installation pin program fault occurred (Ref. TSM TASK 27-51-00-810-846).
(1) If the flap menu is not available:
- Interchange the SFCC's and do again the test in Para. 3.A. on the SLAT/FLAP CONTR.COMP. [21CV] and the SLAT/FLAP CONTR.COMP. [22CV] .
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
1 Put the serviceable SFCC back in its initial position.
2 Replace the unserviceable SFCC.
(b) If the fault does not move to the other SFCC:
- Install the SFCCs in their initial positions.
- For SFCC 1
PROX SNSR R L/G EXT 20GA andPROX SNSR L L/G EXT 21GA - For SFCC 2
PROX SNSR R L/G EXT 22GA andPROX SNSR L L/G EXT 23GA
(4) If the fault continues:
(a) Interchange the RELAY-A/C ON GND [95CV] with the RELAY-A/C ON GND [97CV] .
(b) Do the test in Para. 3.A. on the SFCC 1 and SFCC 2.
(c) If the fault moves to the other system, replace the relay in the system that has the fault.
(d) Do the test in Para. 3.A.
(5) If the fault does not move to the other system, do a check of the
- For SFCC 1 from C/B 6CV to the LGCIU 1 and from the RELAY A/C ON GND 95CV to SFCC 1 ASM 275102.
- For SFCC 2 from C/B 8CV to the LGCIU 2 and from the RELAY A/C ON GND 97CV to SFCC 2 ASM 275103.
(b) Do the test in Para. 3.A.
(6) If the fault continues, make sure that no installation pin program fault occurred (Ref. TSM TASK 27-51-00-810-846).