W DOC AIRBUS | TSM A320F

Flaps - SFCC TEST Gives the Message NO FAULTS BUT


TASK 27-51-00-810-850-A
Flaps - SFCC TEST Gives the Message NO FAULTS BUT


1. Possible Causes

2. Fault Confirmation
Subtask 27-51-00-710-078-A
A. Test
   (1) Do the fault isolation procedure if the FLAPS SFCC TEST gives the message NO FAULTS BUT, with any of the messages that follow:
  • OTHER SFCC ARM SIGNAL NOT TESTED
    or
  • WTB SET
    and/or
  • NO WTB POWER
  • LH WTB SOLENOID S/C (or O/C)
  • RH WTB SOLENOID S/C (or O/C)
  • LH APPU FAULT
  • FPPU FAULT
  • RH APPU FAULT
  • VPS FAULT
3. Fault Isolation
Subtask 27-51-00-810-103-A
A. Procedure
   (1) At the MCDU access the CFDS MENU then LAST LEG REPORT to see if a related fault message was given during normal system operation. The table that follows shows the relationship between the messages given during the SFCC TEST and normal mode, it also gives the related trouble shooting task. Do Para. 4.A. of the applicable task.
NOTE: A fault message given during normal mode will make sure that the fault identified during the SFCC TEST is correct. It will also give the FIN of the defective component.
SFCC TEST MESSAGE
CFDS LAST LEG REPORT MESSAGE
TS TASK IN 27 51 00
OTHER SFCC
SIGNAL NOT
TESTED
FLP 1 (2) NO SFCC 2 (1) DATA
804
NO WTB POWER
FLP 1 (2) WTB C/B 10CV (12CV)
835
LH WTB SOLENOID
S/C (or O/C)
FLP LH WTB BLU (YEL) SOLENOID
33CV OR WIRING TO FLP 1 (2)
836
RH WTB SOLENOID
S/C (or O/C)
FLP RH WTB BLU (GRN) SOLENOID
34CV OR WIRING TO SLT 1 (2)
837
LH APPU FAULT

FPPU FAULT

RH APPU FAULT
LH FLP APPU 29CV OR WIRING TO
FLP 1 (2)
FLP FPPU 27CV OR WIRING TO
FLP 1 (2)
RH FLP APPU 30CV OR WIRING TO
FLP 1 (2)
809

808

809
VPS FAULT
FLP 1 (2) PCU VALVE BLOCK 23CV (24CV) VALVE SENSOR
852
NOTE: The LAST LEG REPORT messages shown are for SFCC 1, the items in ( ) are for SFCC 2.
[Rev.8 from Aug 2018] 2026.04.04 04:27:40 UTC