Flaps - SFCC TEST Gives the Message NO FAULTS BUT
TASK 27-51-00-810-850-A
Flaps - SFCC TEST Gives the Message NO FAULTS BUT
1. Possible Causes
2. Fault Confirmation
Subtask 27-51-00-710-078-A
Subtask 27-51-00-810-103-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:40 UTC
Flaps - SFCC TEST Gives the Message NO FAULTS BUT
1. Possible Causes
2. Fault Confirmation
Subtask 27-51-00-710-078-A
A. Test
(1) Do the fault isolation procedure if the FLAPS SFCC TEST gives the message NO FAULTS BUT, with any of the messages that follow:
3. Fault Isolation(1) Do the fault isolation procedure if the FLAPS SFCC TEST gives the message NO FAULTS BUT, with any of the messages that follow:
- OTHER SFCC ARM SIGNAL NOT TESTED
or - WTB SET
and/or - NO WTB POWER
- LH WTB SOLENOID S/C (or O/C)
- RH WTB SOLENOID S/C (or O/C)
- LH APPU FAULT
- FPPU FAULT
- RH APPU FAULT
- VPS FAULT
Subtask 27-51-00-810-103-A
A. Procedure
(1) At the MCDU access the CFDS MENU then LAST LEG REPORT to see if a related fault message was given during normal system operation. The table that follows shows the relationship between the messages given during the SFCC TEST and normal mode, it also gives the related trouble shooting task. Do Para. 4.A. of the applicable task.
(1) At the MCDU access the CFDS MENU then LAST LEG REPORT to see if a related fault message was given during normal system operation. The table that follows shows the relationship between the messages given during the SFCC TEST and normal mode, it also gives the related trouble shooting task. Do Para. 4.A. of the applicable task.
NOTE: A fault message given during normal mode will make sure that the fault identified during the SFCC TEST is correct. It will also give the FIN of the defective component.
| SFCC TEST MESSAGE | CFDS LAST LEG REPORT MESSAGE | TS TASK IN 27 51 00 |
|---|---|---|
| OTHER SFCC SIGNAL NOT TESTED | FLP 1 (2) NO SFCC 2 (1) DATA | 804 |
| NO WTB POWER | FLP 1 (2) WTB C/B 10CV (12CV) | 835 |
| LH WTB SOLENOID S/C (or O/C) | FLP LH WTB BLU (YEL) SOLENOID 33CV OR WIRING TO FLP 1 (2) | 836 |
| RH WTB SOLENOID S/C (or O/C) | FLP RH WTB BLU (GRN) SOLENOID 34CV OR WIRING TO SLT 1 (2) | 837 |
| LH APPU FAULT FPPU FAULT RH APPU FAULT | LH FLP APPU 29CV OR WIRING TO FLP 1 (2) FLP FPPU 27CV OR WIRING TO FLP 1 (2) RH FLP APPU 30CV OR WIRING TO FLP 1 (2) | 809 808 809 |
| VPS FAULT | FLP 1 (2) PCU VALVE BLOCK 23CV (24CV) VALVE SENSOR | 852 |
NOTE: The LAST LEG REPORT messages shown are for SFCC 1, the items in ( ) are for SFCC 2.