Data Fault Between SFCC 1 and SFCC 2. Loss of Cross-computer Link or Faulty Data
TASK 27-51-00-810-806-A
Data Fault Between SFCC 1 and SFCC 2. Loss of Cross-computer Link or Faulty Data
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-51-00-865-064-A
Subtask 27-51-00-810-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:37 UTC
Data Fault Between SFCC 1 and SFCC 2. Loss of Cross-computer Link or Faulty Data
NOTE: If the SFCC identified as sending NO DATA is under MMEL or failed, this procedure is not applicable. This fault is because of the SFCC failure or MMEL condition.
1. Possible Causes2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 275108 | |
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| AMM 27-54-00-710-001 | Operational Test of the Flap System |
| AMM 31-32-00-860-006 | Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page |
Subtask 27-51-00-865-064-A
A. Table of the circuit breakers used in this procedure:
Subtask 27-51-00-710-055-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
B. Reset and Intialization.
(1) At the circuit breakers:
(a) Open the circuit breakers.
(b) Wait for 3 seconds and close the circuit breakers.
(c) Wait for 60 seconds and do the next step.
(2) At the MCDU set the SYSTEM REPORT/TEST FLT CTL page AMM 31-32-00-860-006:
(a) Set the SFCC related to the flap channel which reported the loss of data.
(b) At the applicable SFCC1 (or SFCC2) SYSTEM STATUS FLAP page:
4. Fault Isolation(1) At the circuit breakers:
(a) Open the circuit breakers.
(b) Wait for 3 seconds and close the circuit breakers.
(c) Wait for 60 seconds and do the next step.
(2) At the MCDU set the SYSTEM REPORT/TEST FLT CTL page AMM 31-32-00-860-006:
(a) Set the SFCC related to the flap channel which reported the loss of data.
(b) At the applicable SFCC1 (or SFCC2) SYSTEM STATUS FLAP page:
- If the message FLP1 NO SFCC2 DATA (or FLP2 NO SFCC1 DATA) is shown, do the fault isolation procedure given in Para. 4.A.
- If a different message is shown, do the trouble shooting procedure related to the message.
- If no message is shown, no further maintenance action is necessary.
Subtask 27-51-00-810-055-A
A. Procedure
(1) Interchange SFCC 1 with SFCC 2,
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(2) Do the test given in Para. 3.B.(2):
(4) Make sure that the serviceable SFCC is installed in its initial position.
(5) If the fault continues, do the next step:
(1) Interchange SFCC 1 with SFCC 2,
AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(2) Do the test given in Para. 3.B.(2):
- If the message stays the same, do step (6)
- If the message goes, do the next step.
(4) Make sure that the serviceable SFCC is installed in its initial position.
(5) If the fault continues, do the next step:
- Replace the opposite SFCC which was not replaced in step (3).
- Do a check and repair the aircraft wiring between SFCC 1 and SFCC 2 ASM 275108.