FLP LH WTB BLU Solenoid 33CV or Open or Short Circuit to SFCC 1 FLP LH WTB YEL Solenoid 33CV or Open or Short Circuit to SFCC 2
TASK 27-51-00-810-836-A
FLP LH WTB BLU Solenoid 33CV or Open or Short Circuit to SFCC 1 FLP LH WTB YEL Solenoid 33CV or Open or Short Circuit to SFCC 2
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 27-51-00-740-067-A
Subtask 27-51-00-810-086-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:39 UTC
FLP LH WTB BLU Solenoid 33CV or Open or Short Circuit to SFCC 1 FLP LH WTB YEL Solenoid 33CV or Open or Short Circuit to SFCC 2
1. Possible Causes
- WTB Solenoid Valve
- WING TIP BRAKE [33CV]
- aircraft wiring
- SLAT/FLAP CONTR.COMP. [21CV]
- SLAT/FLAP CONTR.COMP. [22CV]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | MEGOHMMETER 100 MOHMS - MEASURING VOLTAGE 45 VDC |
| No specific | 1 | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-51-00-740-002 | BITE Test of the Slat and Flap Control Computers (Flap System) |
| ASM 275106 | |
| ASM 275107 | |
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| AMM 27-51-51-000-001 | Removal of the Flap Wing-Tip Brake |
| AMM 27-51-51-000-002 | Removal of the Solenoid Valves of the Flap Wing-Tip Brake (WTB) |
| AMM 27-51-51-400-001 | Installation of the Flap Wing-Tip Brake |
| AMM 27-51-51-400-002 | Installation of the Solenoid Valves of the Flap Wing-Tip Brake (WTB) |
Subtask 27-51-00-740-067-A
A. Test
(1) Do a BITE test on the SFCC 1 or SFCC 2, identified in the failure message AMM 27-51-00-740-002.
(2) If the failure message LH WTB SOLENOID OPEN CIRCUIT (DISCONNECT) or LH WTB SOLENOID SHORT CIRCUIT is shown, do the fault isolation procedure in Para. 4.A.
4. Fault Isolation(1) Do a BITE test on the SFCC 1 or SFCC 2, identified in the failure message AMM 27-51-00-740-002.
(2) If the failure message LH WTB SOLENOID OPEN CIRCUIT (DISCONNECT) or LH WTB SOLENOID SHORT CIRCUIT is shown, do the fault isolation procedure in Para. 4.A.
Subtask 27-51-00-810-086-A
A. Procedure
(5) If the solenoid electrical checks are correct, go to step (7).
(6) If the solenoid electrical checks are not correct:
(a) If the fault does not move to the other SFCC:
1 Install the serviceable SFCC in its initial position.
2 Replace the unserviceable SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] .
3 Do the test in Para. 3.A.
4 Set the MCDU to MENU MODE and get access to the FLP ON GROUND FAULTS page.
Make sure that the ground log is empty.
CAUTION:
DO NOT SWAP FLIGHT CONTROL COMPUTERS. IF THERE IS A SHORT CIRCUIT, YOU WILL CAUSE DAMAGE TO A SERVICEABLE COMPUTER WHEN YOU SWAP THEM.
(1) Disconnect the applicable electrical connector attached to the wing tip brake (33CV) solenoid-valve, identified in the failure message: - For the LH WTB Blue hydraulic-system solenoid, disconnect the connector 33CV-A
- For the LH WTB Yellow hydraulic-system solenoid, disconnect the connector 33CV-B.
- The resistance for the solenoid valve 667C0000-02 must be between 71 ohms and 84 ohms
- The resistance for the solenoid valves 903A0000-01, 1106A0000-1 and 1111A0000-01 must be between 53 ohms and 60 ohms
- The resistance for the solenoid valve 5751A0000-01 must be between 53 ohms and 60 ohms.
- The resistance value must be more than 100 Megohms.
(5) If the solenoid electrical checks are correct, go to step (7).
(6) If the solenoid electrical checks are not correct:
- Replace the applicable WTB Solenoid Valve
AMM 27-51-51-000-002 and AMM 27-51-51-400-002.
- Replace the WING TIP BRAKE [33CV] ,
AMM 27-51-51-000-001 and AMM 27-51-51-400-001.
- The applicable SFCC 1 (2) ARINC tray interface
- The applicable electrical connector 33CV-A or 33CV-B ASM 275106 or ASM 275107.
(a) If the fault does not move to the other SFCC:
- Install the SFCCs in their initial positions.
1 Install the serviceable SFCC in its initial position.
2 Replace the unserviceable SLAT/FLAP CONTR.COMP. [21CV] or SLAT/FLAP CONTR.COMP. [22CV] .
3 Do the test in Para. 3.A.
4 Set the MCDU to MENU MODE and get access to the FLP ON GROUND FAULTS page.
Make sure that the ground log is empty.