General Visual Inspection of Hydraulic Tubing and Hoses (Blocker Doors Deployed) [CFMB]
TASK 78-31-49-210-002-B
General Visual Inspection of Hydraulic Tubing and Hoses (Blocker Doors Deployed)
1. Reason for the Job
Refer to the MPD TASK: 783100-C4
TBD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-49-941-090-A ** ON A/C NOT FOR ALL
Subtask 78-31-49-210-053-A ** ON A/C NOT FOR ALL
Subtask 78-31-49-410-101-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:25:29 UTC
General Visual Inspection of Hydraulic Tubing and Hoses (Blocker Doors Deployed)
1. Reason for the Job
Refer to the MPD TASK: 783100-C4
TBD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-49-000-001-B | Removal of the Left or Right Inner Supply Pipe of the Door-Opening Actuator |
| TASK 78-31-49-000-003-B | Removal of the Upper Swivel Joints |
| TASK 78-31-49-000-006-B | Removal of the Lower Swivel Joints |
| TASK 78-31-49-000-008-B | Removal of the Lower Head Supply Hose |
| TASK 78-31-49-000-009-B | Removal of the Lower Rod Supply Hose |
| TASK 78-31-49-000-025-A | Removal of the Rod Supply Pipe of the Right Actuator |
| TASK 78-31-49-000-026-A | Removal of the Head Supply Pipe of the Right Actuator |
| TASK 78-31-49-000-027-A | Removal of the Upper Head Supply Hose |
| TASK 78-31-49-000-028-A | Removal of the Head Supply Junction Pipe |
| TASK 78-31-49-000-029-A | Removal of the Left or Right Supply Pipe of the Door-Opening Actuator |
| TASK 78-31-49-000-040-C | Removal of the Rod Supply Junction Pipe |
| TASK 78-31-49-000-041-A | Removal of the Return Pipe of the Left Latch |
| TASK 78-31-49-000-042-A | Removal of the Upper Supply Pipe of the Left Latch |
| TASK 78-31-49-000-043-A | Removal of the Lower Supply Pipe of the Left Latch |
| TASK 78-31-49-000-044-A | Removal of the Lower Supply Pipe of the Right Latch |
| TASK 78-31-49-000-045-A | Removal of the Upper Supply Pipe of the Right Latch |
| TASK 78-31-49-000-046-A | Removal of the Return Pipe of the Right Latch |
| TASK 78-31-49-000-047-A | Removal of the Upper Rod Supply Hose |
| TASK 78-31-49-000-048-A | Removal of the Rod Supply Pipe of the Left Actuator |
| TASK 78-31-49-000-049-A | Removal of the Head Supply Pipe of the Left Actuator |
| TASK 78-31-49-400-001-B | Installation of the Left or Right Inner Supply Pipe of the Door-Opening Actuator |
| TASK 78-31-49-400-003-B | Installation of the Upper Swivel Joints |
| TASK 78-31-49-400-006-B | Installation of the Lower Swivel Joints |
| TASK 78-31-49-400-008-B | Installation of the Lower Head Supply Hose |
| TASK 78-31-49-400-009-B | Installation of the Lower Rod Supply Hose |
| TASK 78-31-49-400-025-A | Installation of the Rod Supply Pipe of the Right Actuator |
| TASK 78-31-49-400-026-A | Installation of the Head Supply Pipe of the Right Actuator |
| TASK 78-31-49-400-027-A | Installation of the Upper Head Supply Hose |
| TASK 78-31-49-400-028-A | Installation of the Head Supply Junction Pipe |
| TASK 78-31-49-400-029-A | Installation of the Left or Right Supply Pipe of the Door-Opening Actuator |
| TASK 78-31-49-400-040-C | Installation of the Rod Supply Junction Pipe |
| TASK 78-31-49-400-041-A | Installation of the Return Pipe of the Left Latch |
| TASK 78-31-49-400-042-A | Installation of the Upper Supply Pipe of the Left Latch |
| TASK 78-31-49-400-043-A | Installation of the Lower Supply Pipe of the Left Latch |
| TASK 78-31-49-400-044-A | Installation of the Lower Supply Pipe of the Right Latch |
| TASK 78-31-49-400-045-A | Installation of the Upper Supply Pipe of the Right Latch |
| TASK 78-31-49-400-046-A | Installation of the Return Pipe of the Right Latch |
| TASK 78-31-49-400-047-A | Installation of the Upper Rod Supply Hose |
| TASK 78-31-49-400-048-A | Installation of the Rod Supply Pipe of the Left Actuator |
| TASK 78-31-49-400-049-A | Installation of the Head Supply Pipe of the Left Actuator |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 78-31-49-941-090-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-49-010-125-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040).
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 78-31-49-040-106-A ** ON A/C NOT FOR ALL Subtask 78-31-49-010-126-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040).
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
D. Open the thrust-reverser cowl doors to 33 degree or 35 degree position (as applicable) (Ref. AMM TASK 78-36-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-49-210-053-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the hydraulic tubing and hoses as follows:
5. Close-upSubtask 78-31-49-410-101-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl doors: (Ref. AMM TASK 78-36-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
(3) Remove the access platform(s).
Subtask 78-31-49-440-091-A ** ON A/C NOT FOR ALL Subtask 78-31-49-410-102-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl doors: (Ref. AMM TASK 78-36-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
(3) Remove the access platform(s).
Forward Frame of the Half Door