Removal of the Left or Right Supply Pipe of the Door-Opening Actuator [CFMB]
TASK 78-31-49-000-029-A
Removal of the Left or Right Supply Pipe of the Door-Opening Actuator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-49-941-089-A ** ON A/C NOT FOR ALL
Subtask 78-31-49-020-087-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:25:26 UTC
Removal of the Left or Right Supply Pipe of the Door-Opening Actuator
WARNING:
WEAR A FACE SHIELD WHICH IS RESISTANT TO HIGH PRESSURE JETS WHEN YOU WORK ON PRESSURIZED SYSTEMS.
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
CAUTION:
USE TWO WRENCHES TO REMOVE OR INSTALL THE TUBE COUPLING NUTS:
1. Reason for the Job- ONE WRENCH TO HOLD THE UNION, AND
- ONE TO LOOSEN OR TIGHTEN THE COUPLING NUT.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CONTAINER 5 L (1.32 USGAL) |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
Subtask 78-31-49-941-089-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-49-010-123-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-49-040-115-A ** ON A/C NOT FOR ALL Subtask 78-31-49-010-124-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-49-020-087-A ** ON A/C NOT FOR ALL
A. Removal of the Left or Right Supply Pipe of the Door-Opening Actuator
(1) Put a CONTAINER 5 L (1.32 USGAL) under the lower door-opening pipe connection.
(2) Disconnect the supply pipe from the inner supply pipe and let the hydraulic fluid drain into the container.
(3) Remove the bolt and clamp that attach the supply pipe to the forward frame.
(4) Disconnect the supply pipe from the hydraulic junction box.
(5) Remove the supply pipe from the forward frame.
(6) Put COVER - PROTECTION on the pipe ends.
(1) Put a CONTAINER 5 L (1.32 USGAL) under the lower door-opening pipe connection.
(2) Disconnect the supply pipe from the inner supply pipe and let the hydraulic fluid drain into the container.
(3) Remove the bolt and clamp that attach the supply pipe to the forward frame.
(4) Disconnect the supply pipe from the hydraulic junction box.
(5) Remove the supply pipe from the forward frame.
(6) Put COVER - PROTECTION on the pipe ends.
Supply Pipe of the Door-Opening Actuator