Removal of the Left or Right Inner Supply Pipe of the Door-Opening Actuator [CFMB]
TASK 78-31-49-000-001-B
Removal of the Left or Right Inner Supply Pipe of the Door-Opening Actuator
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-49-941-091-A ** ON A/C NOT FOR ALL
Subtask 78-31-49-020-088-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:24:39 UTC
Removal of the Left or Right Inner Supply Pipe of the Door-Opening Actuator
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CONTAINER 5 L (1.32 USGAL) |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
Subtask 78-31-49-941-091-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-49-010-127-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-49-040-116-A ** ON A/C NOT FOR ALL Subtask 78-31-49-010-128-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-49-020-088-A ** ON A/C NOT FOR ALL
A. Removal of the Left or Right Inner Supply Pipe of the Door-Opening Actuator
(1) Put a CONTAINER 5 L (1.32 USGAL) under the lower door-opening pipe connection.
(2) Disconnect the supply pipe from the inner supply pipe and let the hydraulic fluid drain into the container.
(3) Remove the nut that attach the inner supply pipe to the lower bracket.
(4) Remove the bolts and clamps that attach the supply pipe to the forward frame.
(5) Disconnect the supply hose from the inner supply pipe.
(6) Remove the nut that attach the inner supply pipe to the upper bracket.
(7) Remove the inner supply pipe from the forward frame.
(8) Put COVER - PROTECTION on the pipe ends.
(1) Put a CONTAINER 5 L (1.32 USGAL) under the lower door-opening pipe connection.
(2) Disconnect the supply pipe from the inner supply pipe and let the hydraulic fluid drain into the container.
(3) Remove the nut that attach the inner supply pipe to the lower bracket.
(4) Remove the bolts and clamps that attach the supply pipe to the forward frame.
(5) Disconnect the supply hose from the inner supply pipe.
(6) Remove the nut that attach the inner supply pipe to the upper bracket.
(7) Remove the inner supply pipe from the forward frame.
(8) Put COVER - PROTECTION on the pipe ends.
Inner Supply Pipe of the Door-Opening Actuator