W DOC AIRBUS | AMM A320F

Detailed Inspection of Pylon, Lower Spar, between RIB 1 and RIB 10, Lower Surface


TASK 54-51-00-200-004-A
Detailed Inspection of Pylon, Lower Spar, between RIB 1 and RIB 10, Lower Surface


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
ZONE: 400
ZONE: 415
ZONE: 425
ZONE: 453
ZONE: 463
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 545106-01
DETAILED INSPECTION OF PYLON, LOWER SPAR, BETWEEN RIB 1 AND RIB 10, LOWER SURFACE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
415
LOWER PYLON
425
LOWER PYLON
453
HOT SECTION
463
HOT SECTION
473AL, 483AL
473AR, 473BL, 473CL, 483AR, 483BL, 483CL
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
TASK 54-56-00-000-001-A
Removal of the Lower Fairing
TASK 54-56-00-000-002-A
Removal of the Lower Fairing
TASK 54-56-00-400-001-A
Installation of the Lower Fairing
TASK 54-56-00-400-002-A
Installation of the Lower Fairing
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
SRM 511100
(for corrective action)
SRM 512200
(for corrective action)
3. Job Set-up
Subtask 54-51-00-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC.
Subtask 54-51-00-010-053-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
   (3) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon in zone 470
     (b) For the right pylon in zone 480.
   (4) Remove the lower fairings (Ref. AMM TASK 54-56-00-000-001):
     (a) For the left pylon: 473AL 473AR 473BL 473CL
     (b) For the right pylon: 483AL 483AR 483BL 483CL.
Subtask 54-51-00-010-053-B ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Open the thrust reverser doors (Ref. AMM TASK 78-32-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
   (3) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon in zone 470
     (b) For the right pylon in zone 480.
   (4) Remove the lower fairings (Ref. AMM TASK 54-56-00-000-002):
     (a) For the left pylon: 473AL
     (b) For the right pylon: 483AL.
Subtask 54-51-00-040-054-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-51-00-040-054-B ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
Subtask 54-51-00-110-054-A ** ON A/C NOT FOR ALL
D. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 54-51-00-220-055-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a detailed inspection of the internal structure of the pylon lower spar between RIB1 and RIB10.
   (2) Make sure that there is no:
     (a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 512200 for types of corrosion, inspection, removal and corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for damage classification and related corrective action.
5. Close-up
Subtask 54-51-00-440-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-51-00-440-054-C ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-012).
Subtask 54-51-00-410-053-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Install the lower fairings (Ref. AMM TASK 54-56-00-400-001):
     (a) For the left pylon: 473AL 473AR 473BL 473CL
     (b) For the right pylon: 483AL 483AR 483BL 483CL.
   (2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
   (3) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (4) Make sure that the work area is clean and clear of tools and other items.
   (5) Remove the access platform(s).
   (6) Remove the WARNING NOTICE(S).
Subtask 54-51-00-410-053-C ** ON A/C NOT FOR ALL
B. Close Access
   (1) Install the lower fairings (Ref. AMM TASK 54-56-00-400-002):
     (a) For the left pylon: 473AL
     (b) For the right pylon: 483AL.
   (2) Close the thrust reverser doors (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
   (3) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (4) Make sure that the work area is clean and clear of tools and other items.
   (5) Remove the access platform(s).
   (6) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 01:59:25 UTC