Removal of the Lower Fairing
TASK 54-56-00-000-002-A
Removal of the Lower Fairing
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-56-00-941-053-A ** ON A/C NOT FOR ALL
Subtask 54-56-00-020-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:52:41 UTC
Removal of the Lower Fairing
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
Subtask 54-56-00-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 54-56-00-040-057-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Aircraft Maintenance Configuration
(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
Subtask 54-56-00-010-052-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position:
(a) At zone 470 for the left pylon
(b) At zone 480 for the right pylon.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position:
(a) At zone 470 for the left pylon
(b) At zone 480 for the right pylon.
Subtask 54-56-00-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the Lower Fairing
(1) Remove the bolts (8).
(2) Release the centering pins and remove the lower fairing (9):
(a) For the right pylon: 483AL
(b) For the left pylon: 473AL
(1) Remove the bolts (8).
(2) Release the centering pins and remove the lower fairing (9):
(a) For the right pylon: 483AL
(b) For the left pylon: 473AL
Lower Fairing