Installation of the Oxygen Distribution Manifold
TASK 35-12-81-400-801-A
Installation of the Oxygen Distribution Manifold
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 35-12-81-941-053-A
Subtask 35-12-81-400-050-A ** ON A/C NOT FOR ALL
Subtask 35-12-81-860-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:04:22 UTC
Installation of the Oxygen Distribution Manifold
WARNING:
KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING:
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
ZONE: 125
FIN: 5753HM ** ON A/C NOT FOR ALL
FIN: 5753HM1 ** ON A/C NOT FOR ALL
FIN: 5753HM2 ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 5753HM ** ON A/C NOT FOR ALL
FIN: 5753HM1 ** ON A/C NOT FOR ALL
FIN: 5753HM2 ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft ) ![]() | |
| FOR [5753HM1] (MANIFOLD DISTRIBUTION) | ||
| No specific | Torque wrench: range to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft ) ![]() | |
| FOR [5753HM2] (MANIFOLD DISTRIBUTION) | ||
| No specific | Torque wrench: range to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft ) ![]() | |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14CCB6) | Testing Medium-Leak Detection - Oxygen System |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 125 | LATERAL AVIONIC COMPARTMENT |
| 812 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 9 | RING | AIPC 35-12-01-01-010 |
| 9 | RING | AIPC 35-12-81-01-010 |
| FOR [5753HM1] (MANIFOLD DISTRIBUTION) | ||
| 9 | RING | AIPC 35-12-81-09-010 |
| 9 | RING | AIPC 35-12-81-09-015 |
| FOR [5753HM2] (MANIFOLD DISTRIBUTION) | ||
| 9 | RING | AIPC 35-12-81-11-010 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-23-22-910-001-A | Marking of the Unions after Application of Standard or Specific Tightening Torque |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
| TASK 35-12-00-710-001-A | Functional Check of Low Pressure Switch |
| TASK 35-13-14-400-001-A | Installation of the Low-Pressure Oxygen Pressure-Switch |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| FOR [5753HM1] (MANIFOLD DISTRIBUTION) | |
| TASK 20-23-22-910-001-A | Marking of the Unions after Application of Standard or Specific Tightening Torque |
| TASK 35-13-14-400-802-A | Installation of the Low-Pressure Oxygen Pressure-Switches |
| FOR [5753HM2] (MANIFOLD DISTRIBUTION) | |
| TASK 20-23-22-910-001-A | Marking of the Unions after Application of Standard or Specific Tightening Torque |
| TASK 35-13-14-400-802-A | Installation of the Low-Pressure Oxygen Pressure-Switches |
Subtask 35-12-81-941-053-A
A. Safety Precautions
(2) Make sure that there is good airflow in the work area.
Subtask 35-12-81-861-051-A Subtask 35-12-81-010-051-A WARNING:
WHEN YOU DO WORK ON THE GASEOUS OXYGEN SYSTEM, MAKE SURE THAT YOU OBEY ALL THE APPLICABLE SAFETY PRECAUTIONS. IF YOU DO NOT OBEY THESE PRECAUTIONS, INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT CAN OCCUR.
(1) Obey the special precautions when you do work on the gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).(2) Make sure that there is good airflow in the work area.
C. Get Access
(1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at access door 812.
(2) Make sure that access door 812 is open (Ref. AMM TASK 52-41-00-010-002).
Subtask 35-12-81-860-050-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at access door 812.
(2) Make sure that access door 812 is open (Ref. AMM TASK 52-41-00-010-002).
D. Aircraft Maintenance Configuration
(1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to open the manual shutoff valve of the crew oxygen-storage cylinder (5750HM).
(3) Make sure that the manual shutoff valve of the crew oxygen-storage cylinder (5750HM) is fully closed.
Subtask 35-12-81-860-050-B ** ON A/C NOT FOR ALL (1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to open the manual shutoff valve of the crew oxygen-storage cylinder (5750HM).
(3) Make sure that the manual shutoff valve of the crew oxygen-storage cylinder (5750HM) is fully closed.
D. Aircraft Maintenance Configuration
(1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to open the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2).
(3) Make sure that the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2) are fully closed.
Subtask 35-12-81-865-050-A (1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to open the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2).
(3) Make sure that the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2) are fully closed.
E. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
Subtask 35-12-81-400-050-A ** ON A/C NOT FOR ALL
A. Installation of the Oxygen Distribution Manifold
(1) Do a visual inspection of the component interfaces and the adjacent area.
(2) Clean the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Remove the oxygen distribution manifold (1) from the BAG - VINYL.
(5) Put the oxygen distribution manifold (1) in position on its support (4).
(6) Install the washers (3) and the bolts (2).
(7) Tighten the bolts (2).
(8) Remove the BAG-VINYL and then the PLUG-BLANKING, APPROVED FOR USE WITH OXYGEN from each disconnected line end.
(9) Install the new AIPC 35-12-01-01-010 RING (9) or AIPC 35-12-81-01-010 RING (9) on the oxygen distribution manifold (1).
(10) Make sure that the rings (9) stay in the correct position on the oxygen distribution manifold (1).
(11) Connect the oxygen inlet port (5) and the oxygen outlet port (7) to the oxygen distribution manifold (1).
(12) TORQUE the coupling nuts (6) and (8) to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft )
.
(13) Put a red paint mark on the connection between:
(14) If removed, install the LP oxygen pressure-switch (11) on the oxygen distribution manifold (1) (Ref. AMM TASK 35-13-14-400-001).
(15) Put a red paint mark on the connection between the oxygen distribution manifold (1) and the LP oxygen pressure-switch (11) (Ref. AMM TASK 20-23-22-910-001).
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
Subtask 35-12-81-400-050-B ** ON A/C NOT FOR ALL (1) Do a visual inspection of the component interfaces and the adjacent area.
(2) Clean the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
(4) Remove the oxygen distribution manifold (1) from the BAG - VINYL.
(5) Put the oxygen distribution manifold (1) in position on its support (4).
(6) Install the washers (3) and the bolts (2).
(7) Tighten the bolts (2).
(8) Remove the BAG-VINYL and then the PLUG-BLANKING, APPROVED FOR USE WITH OXYGEN from each disconnected line end.
(9) Install the new AIPC 35-12-01-01-010 RING (9) or AIPC 35-12-81-01-010 RING (9) on the oxygen distribution manifold (1).
(10) Make sure that the rings (9) stay in the correct position on the oxygen distribution manifold (1).
(11) Connect the oxygen inlet port (5) and the oxygen outlet port (7) to the oxygen distribution manifold (1).
(12) TORQUE the coupling nuts (6) and (8) to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft )
.(13) Put a red paint mark on the connection between:
- The oxygen distribution manifold (1) and the oxygen inlet port (5)
- The oxygen distribution manifold (1) and the oxygen outlet port (7)
(14) If removed, install the LP oxygen pressure-switch (11) on the oxygen distribution manifold (1) (Ref. AMM TASK 35-13-14-400-001).
(15) Put a red paint mark on the connection between the oxygen distribution manifold (1) and the LP oxygen pressure-switch (11) (Ref. AMM TASK 20-23-22-910-001).
NOTE: It is not necessary to install a new OXYGEN CLEAN stickers.
(16) Connect the electrical connector (10):(a) Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(b) Connect the electrical connector (10) to the LP oxygen pressure-switch (11).A. Installation of Oxygen Distribution Manifold
(1) FOR [5753HM1] (MANIFOLD DISTRIBUTION)
(a) Do a visual inspection of the component interfaces and the adjacent area.
(b) Clean the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Remove the oxygen distribution manifold (4) from the BAG - VINYL.
(e) Put the oxygen distribution manifold (4) in position on its support (1).
(f) Install the washers (6) and the bolts (5).
(g) Tighten the bolts (5).
(h) Remove the BAG-VINYL and then the PLUG-BLANKING, APPROVED FOR USE WITH OXYGEN from each disconnected line end.
(i) Install the new AIPC 35-12-81-09-010 RING (9) or AIPC 35-12-81-09-015 RING (9) on the oxygen distribution manifold (4).
(j) Make sure that the rings (9) stay in the correct position on the oxygen distribution manifold (4).
(k) Connect the oxygen inlet port (8) and the oxygen outlet ports (11) to the oxygen distribution manifold (4).
(l) TORQUE the coupling nuts (7) and (10) to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft )
.
(m) Put a red paint mark on the connection between:
(n) If removed, install the LP oxygen pressure-switch (3) on the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-400-802).
(o) Put a red paint mark on the connection between the oxygen distribution manifold (4) and the LP oxygen pressure-switch (3) (Ref. AMM TASK 20-23-22-910-001).
1 Remove the CAP-BLANKING from each electrical connector and receptacle.
(2) FOR [5753HM2] (MANIFOLD DISTRIBUTION)
(a) Do a visual inspection of the component interfaces and the adjacent area.
(b) Clean the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Remove the oxygen distribution manifold (4) from the BAG - VINYL.
(e) Put the oxygen distribution manifold (4) in position on its support (12).
(f) Install the washers (6) and the bolts (5).
(g) Tighten the bolts (5).
(h) Remove the BAG-VINYL and then the PLUG-BLANKING, APPROVED FOR USE WITH OXYGEN from each disconnected line end.
(i) Install the new AIPC 35-12-81-11-010 RING (9) on the oxygen distribution manifold (4).
(j) Make sure that the rings (9) stay in the correct position on the oxygen distribution manifold (4).
(k) Connect the oxygen inlet port (8) and the oxygen outlet ports (11) to the oxygen distribution manifold (4).
(l) TORQUE the coupling nuts (7) and (10) to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft )
.
(m) Put a red paint mark on the connection between:
(n) If removed, install the LP oxygen pressure-switch (3) on the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-400-802).
(o) Put a red paint mark on the connection between the oxygen distribution manifold (4) and the LP oxygen pressure-switch (3) (Ref. AMM TASK 20-23-22-910-001).
1 Remove the CAP-BLANKING from each electrical connector and receptacle.
Subtask 35-12-81-865-051-A (1) FOR [5753HM1] (MANIFOLD DISTRIBUTION)
(a) Do a visual inspection of the component interfaces and the adjacent area.
(b) Clean the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Remove the oxygen distribution manifold (4) from the BAG - VINYL.
(e) Put the oxygen distribution manifold (4) in position on its support (1).
(f) Install the washers (6) and the bolts (5).
(g) Tighten the bolts (5).
(h) Remove the BAG-VINYL and then the PLUG-BLANKING, APPROVED FOR USE WITH OXYGEN from each disconnected line end.
(i) Install the new AIPC 35-12-81-09-010 RING (9) or AIPC 35-12-81-09-015 RING (9) on the oxygen distribution manifold (4).
(j) Make sure that the rings (9) stay in the correct position on the oxygen distribution manifold (4).
(k) Connect the oxygen inlet port (8) and the oxygen outlet ports (11) to the oxygen distribution manifold (4).
(l) TORQUE the coupling nuts (7) and (10) to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft )
.(m) Put a red paint mark on the connection between:
- The oxygen distribution manifold (4) and the oxygen inlet port (8)
- The oxygen distribution manifold (4) and the oxygen outlet ports (11)
(n) If removed, install the LP oxygen pressure-switch (3) on the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-400-802).
(o) Put a red paint mark on the connection between the oxygen distribution manifold (4) and the LP oxygen pressure-switch (3) (Ref. AMM TASK 20-23-22-910-001).
NOTE: It is not necessary to install a new OXYGEN CLEAN stickers.
(p) Connect the electrical connector (2):1 Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
2 Connect the electrical connector (2) to the LP oxygen pressure-switch (3).(2) FOR [5753HM2] (MANIFOLD DISTRIBUTION)
(a) Do a visual inspection of the component interfaces and the adjacent area.
(b) Clean the component interfaces and the adjacent area.
(c) Make sure that the parts retained from the removed component are clean and in the correct condition.
(d) Remove the oxygen distribution manifold (4) from the BAG - VINYL.
(e) Put the oxygen distribution manifold (4) in position on its support (12).
(f) Install the washers (6) and the bolts (5).
(g) Tighten the bolts (5).
(h) Remove the BAG-VINYL and then the PLUG-BLANKING, APPROVED FOR USE WITH OXYGEN from each disconnected line end.
(i) Install the new AIPC 35-12-81-11-010 RING (9) on the oxygen distribution manifold (4).
(j) Make sure that the rings (9) stay in the correct position on the oxygen distribution manifold (4).
(k) Connect the oxygen inlet port (8) and the oxygen outlet ports (11) to the oxygen distribution manifold (4).
(l) TORQUE the coupling nuts (7) and (10) to between 20.3 and 14.6 m.N (14.97 and 10.77 lbf.ft )
.(m) Put a red paint mark on the connection between:
- The oxygen distribution manifold (4) and the oxygen inlet port (8)
- The oxygen distribution manifold (4) and the oxygen outlet ports (11)
(n) If removed, install the LP oxygen pressure-switch (3) on the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-400-802).
(o) Put a red paint mark on the connection between the oxygen distribution manifold (4) and the LP oxygen pressure-switch (3) (Ref. AMM TASK 20-23-22-910-001).
NOTE: It is not necessary to install a new OXYGEN CLEAN stickers.
(p) Connect the electrical connector (2):1 Remove the CAP-BLANKING from each electrical connector and receptacle.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
2 Connect the electrical connector (2) to the LP oxygen pressure-switch (3).B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 35-12-81-790-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
C. Leak Check
(1) Remove the WARNING NOTICE(S).
(2) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(3) Apply a layer of Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) to the mechanical connections of the oxygen distribution manifold.
(5) Let the pressure become stable for approximately 90 seconds.
(7) Examine each mechanical connection of the oxygen distribution manifold and make sure that there are no leaks.
(8) Remove the Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) from the connections with a Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 35-12-81-790-050-C ** ON A/C NOT FOR ALL (1) Remove the WARNING NOTICE(S).
(2) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(3) Apply a layer of Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) to the mechanical connections of the oxygen distribution manifold.
CAUTION:
TURN THE MANUAL SHUTOFF VALVES VERY SLOWLY ON ALL THE CREW OXYGEN-STORAGE CYLINDERS UNTIL THEY ARE FULLY OPEN. IF YOU TURN THE MANUAL SHUTOFF VALVES TOO QUICKLY, YOU CAN CAUSE DAMAGE TO THE EQUIPMENT.
(4) Very slowly open the manual shutoff valve (3 to 4 turns) of the crew oxygen-storage cylinder (5750HM).(5) Let the pressure become stable for approximately 90 seconds.
CAUTION:
TURN THE HANDVALVES ON ALL OXYGEN BOTTLES UNTIL THEY ARE FULLY OPEN. IF THE HANDVALVES ARE NOT FULLY OPEN BEFORE FLIGHT, IT IS POSSIBLE THAT THE OXYGEN PRESSURE DATA ON THE ECAM DOOR/OXY PAGE WILL NOT BE CORRECT.
(6) Fully open the manual shutoff valve of the crew oxygen-storage cylinder (5750HM) (7) Examine each mechanical connection of the oxygen distribution manifold and make sure that there are no leaks.
(8) Remove the Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) from the connections with a Textile-Lint free Cotton - (Material No.14SBA1) .
C. Leak Check
(1) Remove the WARNING NOTICE(S).
(2) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(3) Apply a layer of Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) to the mechanical connections of the oxygen distribution manifold.
(5) Examine each mechanical connection of the oxygen distribution manifold and make sure that there are no leaks.
(6) Remove the Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) from the connections with a Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 35-12-81-710-050-A (1) Remove the WARNING NOTICE(S).
(2) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(3) Apply a layer of Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) to the mechanical connections of the oxygen distribution manifold.
CAUTION:
TURN THE MANUAL SHUTOFF VALVES VERY SLOWLY ON ALL THE CREW OXYGEN-STORAGE CYLINDERS UNTIL THEY ARE FULLY OPEN. IF YOU TURN THE MANUAL SHUTOFF VALVES TOO QUICKLY, YOU CAN CAUSE DAMAGE TO THE EQUIPMENT.
CAUTION:
TURN THE HANDVALVES ON ALL OXYGEN BOTTLES UNTIL THEY ARE FULLY OPEN. IF THE HANDVALVES ARE NOT FULLY OPEN BEFORE FLIGHT, IT IS POSSIBLE THAT THE OXYGEN PRESSURE DATA ON THE ECAM DOOR/OXY PAGE WILL NOT BE CORRECT.
(4) Slowly and fully open the manual shutoff valve of the crew oxygen-storage cylinders (5750HM1 and 5750HM2).(5) Examine each mechanical connection of the oxygen distribution manifold and make sure that there are no leaks.
(6) Remove the Testing Medium-Leak Detection - Oxygen System (Material No.14CCB6) from the connections with a Textile-Lint free Cotton - (Material No.14SBA1) .
D. Test
(1) Do the operational test of the crew oxygen distribution (Ref. AMM TASK 35-12-00-710-001).
5. Close-up(1) Do the operational test of the crew oxygen distribution (Ref. AMM TASK 35-12-00-710-001).
Subtask 35-12-81-860-051-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the manual shutoff valve of the crew oxygen-storage cylinder (5750HM) is open.
Subtask 35-12-81-860-051-B ** ON A/C NOT FOR ALL (1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the manual shutoff valve of the crew oxygen-storage cylinder (5750HM) is open.
A. Put the aircraft back to its initial configuration.
(1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2) are fully open.
Subtask 35-12-81-410-050-A (1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
(2) Make sure that the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2) are fully open.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 812 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 35-12-81-862-050-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 812 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Oxygen Distribution Manifold