W DOC AIRBUS | AMM A320F

Deactivation of the Rain Repellent System


TASK 30-45-00-040-002-A
Deactivation of the Rain Repellent System


WARNING: DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
  • FLUSH IT AWAY WITH CLEAN WATER
  • GET MEDICAL AID.
WARNING: MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
WARNING: MAKE SURE THAT YOU DEPRESSURIZE THE RAIN REPELLENT SYSTEM BEFORE YOU REMOVE THE RAIN REPELLENT FLUID-CAN. RAIN REPELLENT FLUID CAN COME OUT SUDDENLY IF YOU REMOVE THE FLUID CAN WITH THE SYSTEM PRESSURIZED.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
CAUTION: DO NOT APPLY THE RAIN REPELLENT FLUID ON A DRY SURFACE.
NOTE: If there is leakage of FORALKYL 2211, you can smell a pine odor.
ZONE: 120
ZONE: 210
1. Reason for the Job
NOTE: This deactivation task is not related to an AFM-CDL/MMEL item.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CONTAINER 3 L(3/4 USGAL)
No specific
1
HOSE - DRAIN
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98F30403000000
1
RAIN REPELLENT SYSTEM
98F30403001000
1
RAIN REPELLENT PRES
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BBD1)
Non Aqueous Cleaner-- Isopropyl Alcohol -
(Material No.08BPA1)
Non Aqueous Cleaner-Non structural use - -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
811
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 30-45-41-000-001-A
Removal of the Rain-Repellent Solenoid Valve
TASK 30-45-41-400-001-A
Installation of the Rain-Repellent Solenoid Valve
TASK 30-45-43-000-001-A
Removal of the Rain-Repellent Fluid Gage Assy
TASK 30-45-43-400-001-A
Installation of the Rain-Repellent Fluid Gage Assy
TASK 30-45-46-000-001-A
Removal of the Rain-Repellent Check Valve
TASK 30-45-46-400-001-A
Installation of the Rain-Repellent Check Valve
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 30-45-00-100-053-A
A. Cleaning Instructions
   (1) Make sure that the fluid does not stay on the aircraft furnishing.
   (2) If there is fluid on the aircraft furnishings, clean it with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) .
Subtask 30-45-00-861-055-A
B. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 30-45-00-865-072-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
** ON A/C ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
** ON A/C NOT FOR ALL
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
Subtask 30-45-00-941-062-A
D. On the overhead control and indicating panels 21VU and 22VU, put a WARNING NOTICE(S) to tell persons not to operate the RAIN RPLNT pushbutton switches.
Subtask 30-45-00-010-060-A
E. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the forward avionics-compartment door 811.
   (2) Open the forward avionics-compartment door 811 to get access to the blowout reservoir (8) (Ref. AMM TASK 52-41-00-010-002).
   (3) In the cockpit, open the access door of the rain-repellent fluid can.
4. Procedure
Subtask 30-45-00-941-063-A
A. Preparation
   (1) Connect a HOSE - DRAIN to the drain valve (4) of the rain-repellent fluid-gage assembly (5).
   (2) Put the hose outlet in a CONTAINER 3 L(3/4 USGAL).
Subtask 30-45-00-870-053-A
B. Depressurization of the System
   (1) Push the pushbutton switch (6) to release the pressure from the system.
   (2) Make sure that no more rain repellent fluid comes out of the hose outlet.
   (3) Remove the HOSE - DRAIN from the drain valve (4).
   (4) Remove the CONTAINER 3 L(3/4 USGAL).
Subtask 30-45-00-020-054-A
C. Removal of the Rain Repellent Fluid-Can
   (1) Remove the clamp (2).
   (2) Loosen and remove the can (1).
   (3) Remove and discard the seal (3).
   (4) Put the PLUG-BLANKING in each disconnected line end.
Subtask 30-45-00-160-052-A
D. Cleaning of the Nozzles
   (1) Remove the blanking plug (9) from the top part of the blowout reservoir (8).
   (2) Connect the hose of the 98F30403000000 RAIN REPELLENT SYSTEM to the top part of the blowout reservoir (8).
   (3) Pressurize the blowout reservoir (8) to 4.38 psi (0.30 bar) with the 98F30403000000 RAIN REPELLENT SYSTEM and the 98F30403001000 RAIN REPELLENT PRES.
NOTE: The air conditioning system can be used as an alternative to the pressure source 98F30403000000 RAIN REPELLENT SYSTEM and the 98F30403001000 RAIN REPELLENT PRES.
   (4) Make sure that the air comes out of the nozzles (7).
NOTE: You can use a solution of soap and water.
   (5) Disconnect the hose from the top part of the blowout reservoir (8).
   (6) Install the blanking plug (9) on the top part of the blowout reservoir (8).
Subtask 30-45-00-020-055-A
E. Removal of the Rain-Repellent Solenoid Valves and the Check Valves
   (1) Remove the rain-repellent solenoid valves (Ref. AMM TASK 30-45-41-000-001).
   (2) Send the rain-repellent solenoid valves to the workshop for cleaning.
   (3) Remove the rain-repellent check valves (Ref. AMM TASK 30-45-46-000-001).
NOTE: You can use these check valves again if they are not damaged. If you find damage, you can discard them.
Subtask 30-45-00-680-051-A
F. Removal of the Rain Repellent Fluid
   (1) Connect the hose of the 98F30403000000 RAIN REPELLENT SYSTEM and the 98F30403001000 RAIN REPELLENT PRES to the disconnected line ends of the solenoid valves in position of the PLUG - BLANKING.
   (2) Put the hose outlet into the CONTAINER 3 L(3/4 USGAL).
   (3) Connect the hose of the 98F30403000000 RAIN REPELLENT SYSTEM to the top part of the rain-repellent fluid-gage assembly (5).
   (4) Pressurize the rain-repellent fluid-gage assembly (5) to a value that is between 29.00 psi (2 bar) and 43.50 psi (3 bar) with the 98F30403000000 RAIN REPELLENT SYSTEM and the 98F30403001000 RAIN REPELLENT PRES.
   (5) Make sure that no more rain repellent fluid comes out of the hose outlet.
   (6) Disconnect the hose from the top part of the rain-repellent fluid-gage assembly (5).
   (7) Remove the rain-repellent fluid-gage assembly (5) (Ref. AMM TASK 30-45-43-000-001) and send it to the shop to clean it.
   (8) Put the funnel of the 98F30403000000 RAIN REPELLENT SYSTEM in position of the rain-repellent fluid-gage assembly (5), at the top part of the disconnected line end.
   (9) Clean the inner part of the lines with Non Aqueous Cleaner-Non structural use - - (Material No.08BPA1) or an equivalent cleaning agent.
   (10) Remove the funnel.
   (11) Connect the hose of the 98F30403000000 RAIN REPELLENT SYSTEM to the disconnected line end of the rain-repellent fluid-gage assembly (5) and dry the lines with compressed air.
   (12) Disconnect the hose from the disconnected line ends of the solenoid valves.
   (13) Put the PLUG-BLANKING in each disconnected line end.
   (14) Remove all the parts of the 98F30403000000 RAIN REPELLENT SYSTEM.
   (15) Install the rain-repellent fluid-gage assembly (5) (Ref. AMM TASK 30-45-43-400-001).
   (16) Install the O-ring (12) (P/N NSA8205-013), the union (10) (P/N MS21902D5) and the cap (11) (P/N MS21914-5D) on the top part of the rain-repellent fluid-gage assembly (5).
Subtask 30-45-00-420-053-A
G. Installation of the Rain-Repellent Solenoid Valves and Check Valves
   (1) Install the rain-repellent check valves (Ref. AMM TASK 30-45-46-400-001).
NOTE: It is not necessary to install the rain-repellent fluid can at this time.
   (2) Install the rain-repellent solenoid valves (Ref. AMM TASK 30-45-41-400-001).
NOTE: It is not necessary to install the rain-repellent fluid can at this time.
5. Close-up
Subtask 30-45-00-942-058-A
A. Put the aircraft back to its initial configuration.
   (1) Remove the WARNING NOTICE(S).
NOTE: On the panels 21VU and 22VU put "RAIN REPELLENT DEACTIVATED" placards adjacent to the RAIN RPLNT pushbutton switches.
   (2) Make an entry in the logbook.
Subtask 30-45-00-410-060-A
B. Close Access
   (1) Remove all the fixtures, tools, test and support equipment used during this procedure.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) In the cockpit, close the access door of the rain-repellent fluid can.
   (4) Close the forward avionics-compartment door 811 (Ref. AMM TASK 52-41-00-410-002).
   (5) Remove the access platform(s).
Subtask 30-45-00-865-079-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
Subtask 30-45-00-862-055-A
D. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 00:31:08 UTC