W DOC AIRBUS | AMM A320F

Installation of the Rain-Repellent Fluid Gage Assy


TASK 30-45-43-400-001-A
Installation of the Rain-Repellent Fluid Gage Assy


WARNING: DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
  • FLUSH IT AWAY WITH CLEAN WATER
  • GET MEDICAL AID.
WARNING: THE RAIN REPELLENT FLUID GAGE IS CONSIDERED AS AN ASSEMBLY. THE COMPONENTS OF THIS ASSEMBLY, ESPECIALLY THE PRESSURE GAGE, MUST NOT BE REPLACED ON AIRCRAFT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
NOTE: If there is leakage of FORALKYL 2211, you can smell a pine odor.
ZONE: 211
FIN: 2DM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BBD1)
Non Aqueous Cleaner-- Isopropyl Alcohol -
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
16
RAIN-REPELLENT FLUID CAN
AIPC 30-45-01-06-020
17
SEAL
AIPC 30-45-01-06-027
7
PACKING
AIPC 30-45-01-06-050
7
PACKING
AIPC 30-45-81-06-040
17
SEAL
AIPC 30-45-81-06-060
16
RAIN-REPELLENT FLUID CAN
AIPC 30-45-81-06-080
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 30-45-00-720-002-A
Functional Test of the Rain Repellent System (with the Air Compressor)
TASK 30-45-00-720-002-B
Functional Test of the Rain Repellent System (with the Air Conditioning System)
3. Job Set-up
Subtask 30-45-43-100-051-A
A. Cleaning Instructions
   (1) Make sure that the fluid does not stay on the aircraft furnishings.
If the fluid gets on the aircraft furnishings, clean with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) .
Subtask 30-45-43-860-050-A
B. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
   (2) On the overhead control and indicating panels 21VU and 22VU:
  • Make sure that the warning notices are in position to tell persons not to operate the RAIN RPLNT pushbutton switches.
   (3) Make sure that the access door to the rain repellent fluid gage assy (6) is open.
Subtask 30-45-43-865-051-A
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
4. Procedure
Subtask 30-45-43-420-052-A
A. Installation of the Rain-Repellent Fluid Gage Assy
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Install the rain-repellent fluid gage assy (6) between the brackets.
   (4) Install the screws (2), (3), (10) and (11) with the washers (1), (4), (12) and (13) and tighten them.
   (5) Remove the PLUG-BLANKING from each disconnected line end.
   (6) Install a new AIPC 30-45-01-06-050 PACKING (7) or AIPC 30-45-81-06-040 PACKING (7) with the union (8).
   (7) Install the line (9).
Subtask 30-45-43-420-053-A Subtask 30-45-43-210-051-A
C. Inspection/Check
   (1) Push the purge pushbutton (5) to pressurize the system until the fluid is in its maximum level.
   (2) Make sure that the needle of the pressure gage is in the green area.
   (3) Make sure that there are no leaks.
Subtask 30-45-43-942-051-A
D. Close-up operation
   (1) Disconnect the hose from the drain valve (14).
Subtask 30-45-43-720-050-A
5. Close-up
Subtask 30-45-43-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/RAIN/RPLNT/CAPT1DB1D01
122VUANTI ICE/RAIN/RPLNT/F/O1DB2W11
Subtask 30-45-43-410-051-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the WARNING NOTICE(S).
   (3) Close the access door of the rain-repellent fluid gage assy (6).
Subtask 30-45-43-862-050-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 08:21:46 UTC