Functional Test of the Rain Repellent System (with the Air Compressor)
TASK 30-45-00-720-002-A
Functional Test of the Rain Repellent System (with the Air Compressor)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 30-45-00-861-051-A Subtask 30-45-00-865-067-A
Subtask 30-45-00-875-050-B ** ON A/C NOT FOR ALL
Subtask 30-45-00-010-050-A
Subtask 30-45-00-720-051-A
Subtask 30-45-00-080-050-A
Subtask 30-45-00-862-051-A
[Rev.10 from 2021]
2026.04.01 00:31:14 UTC
Functional Test of the Rain Repellent System (with the Air Compressor)
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
CAUTION:
DO NOT APPLY THE RAIN REPELLENT FLUID ON A DRY SURFACE.
CAUTION:
REMOVE THE RAIN REPELLENT FLUID FROM THE WINDSHIELD AND FROM ALL THE OTHER SURFACES IT TOUCHES WITH SOAP AND WATER. DO THIS EACH TIME YOU APPLY THE RAIN REPELLENT FLUID.
1. Reason for the JobNOTE: There is an alternative method for this procedure. This task gives one of the methods. For the other method, refer to the other task in this page block.
NOTE: Two persons are necessary to do this task. One person does the rain repellent test and the other person cleans the windshield with water during the test.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | 1 | AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY |
| 98F30403000000 | 1 | RAIN REPELLENT SYSTEM |
| 98F30403001000 | 1 | RAIN REPELLENT PRES |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 811 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 2 | O-RING | AIPC 30-45-01-04-080 |
| 7 | O-RING | AIPC 30-45-01-04-080 |
| 2 | O-RING | AIPC 30-45-81-04-060 |
| 7 | O-RING | AIPC 30-45-81-04-060 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 30-45-00-861-051-A Subtask 30-45-00-865-067-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 30-45-00-875-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ANTI ICE/RAIN/RPLNT/CAPT | 1DB1 | D01 |
| 122VU | ANTI ICE/RAIN/RPLNT/F/O | 1DB2 | W11 |
WARNING:
OPEN THE PROBE HEATER CIRCUIT-BREAKERS 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3) BEFORE YOU OPEN THE CIRCUIT BREAKERS 2KS1 OR 2KS2. IF YOU DO NOT OBEY THIS SEQUENCE:
- THIS PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
WARNING:
MAKE SURE THAT YOU OPEN THE CIRCUIT BREAKERS AS FOLLOWS:
- 1JH, 2JH1 AND 3JH1 BEFORE 2KS1
- 1JH, 2JH2 AND 3JH2 BEFORE 2KS2.
WARNING:
BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
C. Open, safety and tag these circuit breakers in this sequence:| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/1 AND 2/IGN/SYS A | 1JH | A03 |
| 121VU | ENGINE/IGN/ENG1/SYS B | 3JH1 | P41 |
| 121VU | ENGINE/IGN/ENG1/SYS A BAT | 2JH1 | P39 |
| 121VU | ENGINE/IGN/ENG2/SYS B | 3JH2 | P42 |
| 121VU | ENGINE/IGN/ENG2/SYS A BAT | 2JH2 | P40 |
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R41 |
| 121VU | ENGINE/ENG2/FADEC B | 4KS2 | Q40 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
WARNING:
OPEN THE PROBE HEATER CIRCUIT-BREAKERS 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3) BEFORE YOU OPEN THE CIRCUIT BREAKERS 2KS1 OR 2KS2. IF YOU DO NOT OBEY THIS SEQUENCE:
- THIS PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
WARNING:
MAKE SURE THAT YOU OPEN THE CIRCUIT BREAKERS AS FOLLOWS:
- 1JH AND 3JH1 BEFORE 2KS1
- 1JH AND 3JH2 BEFORE 2KS2.
WARNING:
BEFORE YOU OPEN PHC CIRCUIT BREAKERS 2DA1(2,3), OPEN PROBE HEATER CIRCUIT-BREAKERS 1DA1(2), 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE:
- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
C. Open, safety and tag these circuit breakers in this sequence:| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/1 AND 2/IGN/SYS A | 1JH | A03 |
| 121VU | ENGINE/IGN/ENG1/SYS B | 3JH1 | P41 |
| 121VU | ENGINE/IGN/ENG2/SYS B | 3JH2 | P42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R41 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R40 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | Q40 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | R41 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
D. Get Access
(1) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
(2) Open access door 811 (Ref. AMM TASK 52-41-00-010-002).
Subtask 30-45-00-480-050-A (1) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
(2) Open access door 811 (Ref. AMM TASK 52-41-00-010-002).
E. Pressurization of the Rain Repellent System with the Air Compressor
(2) Remove and discard the O-ring (2).
(3) Install a new AIPC 30-45-01-04-080 O-RING (7) or AIPC 30-45-81-04-060 O-RING (7) on the reducer (6).
(5) Connect the hose (3) of the 98F30403000000 RAIN REPELLENT SYSTEM tool to the reducer (6) and the 98F30403001000 RAIN REPELLENT PRES (5).
(7) Blow the compressed air with a pressure of 0.3 bar (4 psi) to the system through the blowout reservoir (8).
4. ProcedureWARNING:
DO NOT COMPRESS THE BLOWOUT RESERVOIR ABOVE 7 BAR (101.53 PSI). THIS CAN CAUSE INJURY TO MAINTENANCE PERSONNEL AND DAMAGE TO EQUIPMENT.
(1) Remove the blanking plug (1) from the top of the blowout reservoir (8). (2) Remove and discard the O-ring (2).
(3) Install a new AIPC 30-45-01-04-080 O-RING (7) or AIPC 30-45-81-04-060 O-RING (7) on the reducer (6).
NOTE: The reducer (6) and the hose (3) are the parts of the 98F30403000000 RAIN REPELLENT SYSTEM tool.
(4) Install the reducer (6) together with the O-ring (7) on the blowout reservoir (8).(5) Connect the hose (3) of the 98F30403000000 RAIN REPELLENT SYSTEM tool to the reducer (6) and the 98F30403001000 RAIN REPELLENT PRES (5).
NOTE: The 98F30403001000 RAIN REPELLENT PRES (5) is used together with the 98F30403000000 RAIN REPELLENT SYSTEM.
(6) Connect the hose (4) of the 98F30403001000 RAIN REPELLENT PRES (5) to the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY and the 98F30403001000 RAIN REPELLENT PRES (5). (7) Blow the compressed air with a pressure of 0.3 bar (4 psi) to the system through the blowout reservoir (8).
NOTE: We recommend that you blow the compressed air during the test to prevent the fluid in the nozzles after the test.
Subtask 30-45-00-720-051-A
A. Functional Test of the Rain Repellent System
(1) Do a check of the CAPT and the F/O nozzles to make sure that:
(2) Clean the windshield with water to remove the remaining rain repellent fluid.
(3) After you complete the functional test of the rain repellent system, make sure that:
5. Close-up(1) Do a check of the CAPT and the F/O nozzles to make sure that:
- The compressed air goes out through the CAPT and the F/O nozzles:
| ACTION | RESULT |
|---|---|
1.On the WIPER section of panel 21VU (22VU):
|
|
| 2.Open circuit breaker 1DB1 (1DB2). | |
3.On the WIPER section of panel 21VU (22VU):
|
|
| 4.Close circuit breaker 1DB1 (1DB2). | |
5.On the WIPER section of panel 21VU (22VU):
|
|
| 6.Close circuit breakers 2KS1, 2KS2, 4KS1 and 4KS2. | |
7.On the WIPER section of panel 21VU (22VU):
|
|
(3) After you complete the functional test of the rain repellent system, make sure that:
- The area around the windshield is clear.
- The windshield is clean and clear of all items.
Subtask 30-45-00-080-050-A
A. Stop the Pressurization with the Air Compressor
(1) Stop the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY.
(2) Disconnect the hose (4) from the pressure source and the 98F30403001000 RAIN REPELLENT PRES (5).
(3) Disconnect the hose (3) from the reducer (6) and the 98F30403001000 RAIN REPELLENT PRES (5).
(4) Remove the reducer (6) with the O-ring (7) from the blowout reservoir (8).
(5) Remove and discard the O-ring (7) from the reducer (6).
(6) Install a new AIPC 30-45-01-04-080 O-RING (2) or AIPC 30-45-81-04-060 O-RING (2) on the blanking plug (1).
(7) Put the blanking plug (1) in position in the disconnected line end of the blowout reservoir (8).
Subtask 30-45-00-410-050-A (1) Stop the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY.
(2) Disconnect the hose (4) from the pressure source and the 98F30403001000 RAIN REPELLENT PRES (5).
(3) Disconnect the hose (3) from the reducer (6) and the 98F30403001000 RAIN REPELLENT PRES (5).
(4) Remove the reducer (6) with the O-ring (7) from the blowout reservoir (8).
(5) Remove and discard the O-ring (7) from the reducer (6).
(6) Install a new AIPC 30-45-01-04-080 O-RING (2) or AIPC 30-45-81-04-060 O-RING (2) on the blanking plug (1).
(7) Put the blanking plug (1) in position in the disconnected line end of the blowout reservoir (8).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 811 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 30-45-00-865-053-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 811 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
WARNING:
CLOSE THE CIRCUIT-BREAKER 2KS1 OR 2KS2 BEFORE YOU CLOSE THE PROBE HEATER CIRCUIT-BREAKERS 3DA1(2,3), 4DA1(2,3) AND 5DA1(2,3). IF YOU DO NOT OBEY THIS SEQUENCE:
C. Remove the safety clips and tags and close these circuit breakers in this sequence:- THIS PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/IGN/ENG2/SYS A BAT | 2JH2 | P40 |
| ** ON A/C ALL | |||
| 121VU | ENGINE/IGN/ENG2/SYS B | 3JH2 | P42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/IGN/ENG1/SYS A BAT | 2JH1 | P39 |
| ** ON A/C ALL | |||
| 121VU | ENGINE/IGN/ENG1/SYS B | 3JH1 | P41 |
| 49VU | ENGINE/1 AND 2/IGN/SYS A | 1JH | A03 |
Rain-Repellent Blowout Reservoir