Removal of the Rain-Repellent Check Valve
TASK 30-45-46-000-001-A
Removal of the Rain-Repellent Check Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 30-45-46-100-050-A
Subtask 30-45-46-020-052-A
[Rev.10 from 2021]
2026.04.01 00:31:27 UTC
Removal of the Rain-Repellent Check Valve
WARNING:
DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
- FLUSH IT AWAY WITH CLEAN WATER
- GET MEDICAL AID.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
CAUTION:
MAKE SURE THAT THE FLUID DOES NOT STAY ON THE AIRCRAFT STRUCTURE. IF THE FLUID GETS ON THE AIRCRAFT STRUCTURE, WASH IT OFF IMMEDIATELY WITH SOAP AND WATER.
NOTE: If there is leakage of FORALKYL 2211, you can smell a pine odor.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CONTAINER 3 L(3/4 USGAL) |
| No specific | 1 | HOSE - PLASTIC |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBD1) | Non Aqueous Cleaner-- Isopropyl Alcohol - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 30-45-00-600-001-A | Servicing of the Rain Repellent Fluid Can |
Subtask 30-45-46-100-050-A
A. Cleaning Instructions
(1) Make sure that the fluid does not stay on the aircraft furnishings.
If the fluid gets on the aircraft furnishings, clean with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) .
Subtask 30-45-46-865-053-A (1) Make sure that the fluid does not stay on the aircraft furnishings.
If the fluid gets on the aircraft furnishings, clean with Non Aqueous Cleaner-- Isopropyl Alcohol - (Material No.08BBD1) .
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 30-45-46-941-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 3DM (CHECK VALVERAIN RPLNT) | |||
| 49VU | ANTI ICE/RAIN/RPLNT/CAPT | 1DB1 | D01 |
| FOR FIN: 4DM (CHECK VALVERAIN RPLNT) | |||
| 122VU | ANTI ICE/RAIN/RPLNT/F/O | 1DB2 | W11 |
C. Preparation
(1) Remove the protective cap from the drain valve.
(2) Connect a HOSE - PLASTIC to the drain valve of the rain-repellent fluid gage assy.
(3) Put the hose outlet in a CONTAINER 3 L(3/4 USGAL).
Subtask 30-45-46-869-052-A ** ON A/C NOT FOR ALL (1) Remove the protective cap from the drain valve.
(2) Connect a HOSE - PLASTIC to the drain valve of the rain-repellent fluid gage assy.
(3) Put the hose outlet in a CONTAINER 3 L(3/4 USGAL).
D. Depressurization of the System
(2) Disconnect the hose from the drain valve.
(3) Install the protective cap on the drain valve.
Subtask 30-45-46-020-051-A ** ON A/C NOT FOR ALL Subtask 30-45-46-010-051-A CAUTION:
MAKE SURE THAT THE HOSE OUTLET IS IN THE CONTAINER.
(1) Push the purge pushbutton of the fluid gage to release the pressure from the system. (2) Disconnect the hose from the drain valve.
(3) Install the protective cap on the drain valve.
F. Get Access
(1) Loosen the four quarter-turn fasteners.
(2) Remove the panel 211LW.
4. Procedure(1) Loosen the four quarter-turn fasteners.
(2) Remove the panel 211LW.
Subtask 30-45-46-020-052-A
A. Removal of the Check Valve
(1) Disconnect the line (3) from the union (2).
(2) Put the PLUG-BLANKING in each disconnected line end.
(3) Remove the check valve (1) and its union (2).
(4) Remove and discard the O-ring (5) from the mounting base (6) of the spray nozzle.
(5) Remove the union (2) from the check valve (1).
(6) Remove the O-ring (4) and discard it.
(7) Put a blanking plug on the mounting base (6) of the spray nozzle.
(1) Disconnect the line (3) from the union (2).
(2) Put the PLUG-BLANKING in each disconnected line end.
(3) Remove the check valve (1) and its union (2).
(4) Remove and discard the O-ring (5) from the mounting base (6) of the spray nozzle.
(5) Remove the union (2) from the check valve (1).
(6) Remove the O-ring (4) and discard it.
(7) Put a blanking plug on the mounting base (6) of the spray nozzle.
Rain-Repellent Check Valve