Visual Check of Cargo Compartment Decompression, Lining, Floor Panels and Pressure Compensation Valve (as far as Visible, if ACT(s) or Sliding Carpet System Installed)
TASK 25-50-00-200-002-A
Visual Check of Cargo Compartment Decompression, Lining, Floor Panels and Pressure Compensation Valve (as far as Visible, if ACT(s) or Sliding Carpet System Installed)
Refer to the MPD TASK: 255000-01
VISUAL CHECK OF CARGO COMPARTMENT DECOMPRESSION, LINING, FLOOR PANELS AND PRESSURE COMPENSATION VALVE (AS FAR AS VISIBLE, IF ACT(S) OR SLIDING CARPET SYSTEM INSTALLED).
To make sure that the cargo compartment is airtight.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-50-00-010-061-A ** ON A/C NOT FOR ALL
Subtask 25-50-00-210-057-A
Subtask 25-50-00-865-128-A
[Rev.10 from 2021]
2026.03.31 23:36:56 UTC
Visual Check of Cargo Compartment Decompression, Lining, Floor Panels and Pressure Compensation Valve (as far as Visible, if ACT(s) or Sliding Carpet System Installed)
CAUTION:
BE CAREFUL WHEN YOU INSPECT THE SEALING OF THE CARGO COMPARTMENT LININGS, SIDEWALL PANELS, CEILING PANELS, BALL MATS, PARTITION WALLS, FLOOR PANELS AND COVER PLATES.
MAKE SURE THAT THE CARGO COMPARTMENTS ARE CORRECTLY SEALED. PRESSURE LEAKS THROUGH THE CARGO COMPARTMENT CAN CAUSE A DECREASE IN THE PERFORMANCE OF THE FIRE EXTINGUISHING SYSTEM, IF A FIRE OCCURS.
1. Reason for the JobRefer to the MPD TASK: 255000-01
VISUAL CHECK OF CARGO COMPARTMENT DECOMPRESSION, LINING, FLOOR PANELS AND PRESSURE COMPENSATION VALVE (AS FAR AS VISIBLE, IF ACT(S) OR SLIDING CARPET SYSTEM INSTALLED).
To make sure that the cargo compartment is airtight.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-50-00-200-024-A | Cargo Compartment Linings with Honeycomb Core - General Repair/Protection Information |
| TASK 25-54-11-400-001-A | Installation of the Forward Cargo-Compartment Partition FR24A |
| TASK 25-54-12-000-001-A | Removal of the Forward Cargo-Compartment Partition |
| TASK 25-54-12-300-001-A | Fasteners Missing from the Lining Panels of the Forward Cargo Compartment |
| TASK 25-54-12-400-001-A | Installation of the Forward Cargo-Compartment Partition |
| TASK 25-54-12-400-002-A | Installation of the Ceiling Panels in the Forward Cargo Compartment |
| TASK 25-54-12-400-003-A | Installation of the Sidewall Panels in the Forward Cargo Compartment |
| TASK 25-55-11-300-001-A | Fasteners Missing from the Lining Panels of the Aft Cargo Compartment |
| TASK 25-55-11-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR47 |
| TASK 25-55-11-400-002-A | Installation of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59 |
| TASK 25-55-11-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 25-55-12-000-001-A | Removal of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-300-001-A | Fasteners Missing from the Lining Panels of the Bulk Cargo Compartment |
| TASK 25-55-12-400-001-A | Installation of the Aft Cargo-Compartment Partition at FR65 |
| TASK 25-55-12-400-002-A | Installation of the Ceiling Panels in the Aft Cargo Compartment at FR59/FR65 |
| TASK 25-55-12-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR59/FR65 |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 53-42-14-400-001-A | Installation of the Aft Cargo-Compartment Floor-Panels Zone 150 |
| TASK 53-42-14-400-001-A-01 | Installation of the Aft Cargo-Compartment Floor-Panels (Alternative Installation Procedure with the Skyflex Option) |
| TASK 25-50-00-200-024-A | Cargo Compartment Linings with Honeycomb Core - General Repair/Protection Information (for corrective action) |
| TASK 25-50-00-340-002-A | Repair of the Flanges of the Cargo-Compartment Decompression Panels (for corrective action) |
| TASK 51-76-11-300-001-A | Repair of the Sealing (for corrective action) |
| TASK 53-22-14-000-001-A | Removal of the Forward Cargo-Compartment Floor-Panels (for corrective action) |
| TASK 53-22-14-400-001-A | Installation of the Forward Cargo-Compartment Floor-Panels (for corrective action) |
| TASK 53-22-14-400-001-A-01 | Installation of the Forward Cargo-Compartment Floor-Panels (Alternative Installation Procedure with the Skyflex Option) (for corrective action) |
| TASK 53-42-14-000-001-A | Removal of the Aft Cargo-Compartment Floor-Panels Zone 150 (for corrective action) |
| TASK 53-42-14-400-001-A | Installation of the Aft Cargo-Compartment Floor-Panels Zone 150 (for corrective action) |
| TASK 53-42-14-400-001-A-01 | Installation of the Aft Cargo-Compartment Floor-Panels (Alternative Installation Procedure with the Skyflex Option) (for corrective action) |
| SRM 530200 | (for corrective action) |
Subtask 25-50-00-010-061-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
(2) Open the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward and/or aft cargo-compartment door(s).
(4) Set the light switch to on.
(5) Put the WARNING NOTICE(S) on the control panel(s) of the cargo loading system to tell persons not to use it.
Subtask 25-50-00-010-061-C ** ON A/C NOT FOR ALL (1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
(2) Open the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward and/or aft cargo-compartment door(s).
(4) Set the light switch to on.
(5) Put the WARNING NOTICE(S) on the control panel(s) of the cargo loading system to tell persons not to use it.
A. Get Access
(1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
(2) Open the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward and/or aft cargo-compartment door(s).
(4) Set the light switch to on.
Subtask 25-50-00-865-127-A (1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
(2) Open the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the forward and/or aft cargo-compartment door(s).
(4) Set the light switch to on.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | SEMI AUTO CLS-FWD | 3MY | E08 |
| 2000VU | SEMI AUTO CLS-FWD | 2MY | E06 |
| 2001VU | SEMI AUTO CLS-AFT | 103MY | D08 |
| 2001VU | SEMI AUTO CLS-AFT | 102MY | D06 |
Subtask 25-50-00-210-057-A
A. Visual Inspection of the Decompression, Lining, Floor Panels and Pressure Compensation Valve
Decompression Panel ** ON A/C NOT FOR ALL
Decompression Panel ** ON A/C NOT FOR ALL
Decompression Panel ** ON A/C NOT FOR ALL
(a) Examine each decompression panel for cracks and other damage.
(b) If a decompression panel is damaged, refer to (Ref. AMM TASK 25-50-00-200-024) (Ref. AMM TASK 25-50-00-340-002).
(c) Make sure that each decompression panel has a seal installed, missing seals are not permitted.
(d) Make sure that the seal of each decompression panel is in the correct condition.
(e) Make sure that each decompression panel is in the correct position.
(2) Lining panels:
(a) Examine each lining panel for cracks and other damage.
(b) If a lining panel is damaged, refer to (Ref. AMM TASK 25-50-00-200-024).
(c) Make sure that each lining panel has a seal installed, missing seals are not permitted.
(d) Make sure that the seal of each lining panel are in the correct condition.
(e) Make sure that each lining panel is in the correct position.
(f) Make sure that the linings panels are correctly attached:
1 Tighten the loose fasteners to the correct torque value:
(a) Examine each floor panel for:
(c) Make sure that the floor panels are correctly installed.
(d) If the section hoses come out of the space between floor panels, refer to (Ref. AMM TASK 53-42-14-400-001).
(e) Make sure that the sealant at the floor panel joints is in the correct condition.
(f) If the sealant is damaged, repair it (Ref. AMM TASK 51-76-11-300-001).
(4) Pressure compensation valve:
(a) Make sure that each pressure compensation valve (4) is in closed position.
(b) If a pressure compensation valve (4) is in open position, close it:
1 Remove the partition panel (5) to get access to the pressure compensation valve (4) (Ref. AMM TASK 25-54-12-000-001) or (Ref. AMM TASK 25-55-12-000-001).
2 Hold the pressure compensation valve (4).
3 Loosen the studs (2) and remove the cover (3).
4 Push the pin (1) in the closed position.
5 Put the cover (3) in its correct installation position.
6 TORQUE the studs (2) to between 0.060 and 0.055 m.daN (5.31 and 4.87 lbf.in )
.
5. Close-upWARNING:
USE GOGGLES AND PROTECTIVE CLOTHING WHEN YOU REMOVE, INSTALL OR TORQUE THE FASTENER.
IF PARTS OF THE FASTENER RELEASE SUDDENLY, THERE IS A RISK OF INJURY.
CAUTION:
WHEN THE RELEASE FUNCTION OF THE BRACKET (SPRING-LOADED CATCH) WAS OPERATED, REPLACE THE FASTENER ASSEMBLY WITH THE SILVER METALLIC WASHERS.
DO NOT INSTALL FASTENER ASSEMBLIES WITH WHITE WASHERS TOGETHER WITH FASTENER ASSEMBLIES WITH SILVER METALLIC WASHERS ON THE SAME PANEL.
THIS CAN CAUSE MALFUNCTION OF THE RELATED PANEL.
(1) Decompression panels:
Decompression Panel ** ON A/C NOT FOR ALL
Decompression Panel ** ON A/C NOT FOR ALL
Decompression Panel ** ON A/C NOT FOR ALL (b) If a decompression panel is damaged, refer to (Ref. AMM TASK 25-50-00-200-024) (Ref. AMM TASK 25-50-00-340-002).
(c) Make sure that each decompression panel has a seal installed, missing seals are not permitted.
(d) Make sure that the seal of each decompression panel is in the correct condition.
(e) Make sure that each decompression panel is in the correct position.
(2) Lining panels:
(a) Examine each lining panel for cracks and other damage.
(b) If a lining panel is damaged, refer to (Ref. AMM TASK 25-50-00-200-024).
(c) Make sure that each lining panel has a seal installed, missing seals are not permitted.
(d) Make sure that the seal of each lining panel are in the correct condition.
(e) Make sure that each lining panel is in the correct position.
(f) Make sure that the linings panels are correctly attached:
1 Tighten the loose fasteners to the correct torque value:
- (Ref. AMM TASK 25-54-11-400-001)
- (Ref. AMM TASK 25-54-12-400-001)
- (Ref. AMM TASK 25-54-12-400-002)
- (Ref. AMM TASK 25-54-12-400-003)
- (Ref. AMM TASK 25-55-11-400-001)
- (Ref. AMM TASK 25-55-11-400-002)
- (Ref. AMM TASK 25-55-11-400-003)
- (Ref. AMM TASK 25-55-12-400-001)
- (Ref. AMM TASK 25-55-12-400-002)
- (Ref. AMM TASK 25-55-12-400-003).
- Fasteners Missing from the Lining Panels of the Forward Cargo Compartment (Ref. AMM TASK 25-54-12-300-001)
- Fasteners Missing from the Lining Panels of the Aft Cargo Compartment (Ref. AMM TASK 25-55-11-300-001)
- Fasteners Missing from the Lining Panels of the Bulk Cargo Compartment (Ref. AMM TASK 25-55-12-300-001).
(a) Examine each floor panel for:
- Impact damage
- Deep scratches
- Cracks
- Deformation
- Delamination.
NOTE: The strips of different colors are not considered as a damage of the floor panel. The bright points of the panel edge are not considered as a damage of the floor panel.
(b) If a floor panel is damaged, do a repair SRM 530200 or replace the panel (Ref. AMM TASK 53-22-14-000-001) (Ref. AMM TASK 53-42-14-000-001) or (Ref. AMM TASK 53-22-14-400-001) (Ref. AMM TASK 53-42-14-400-001). (c) Make sure that the floor panels are correctly installed.
(d) If the section hoses come out of the space between floor panels, refer to (Ref. AMM TASK 53-42-14-400-001).
(e) Make sure that the sealant at the floor panel joints is in the correct condition.
(f) If the sealant is damaged, repair it (Ref. AMM TASK 51-76-11-300-001).
(4) Pressure compensation valve:
(a) Make sure that each pressure compensation valve (4) is in closed position.
(b) If a pressure compensation valve (4) is in open position, close it:
1 Remove the partition panel (5) to get access to the pressure compensation valve (4) (Ref. AMM TASK 25-54-12-000-001) or (Ref. AMM TASK 25-55-12-000-001).
2 Hold the pressure compensation valve (4).
3 Loosen the studs (2) and remove the cover (3).
4 Push the pin (1) in the closed position.
5 Put the cover (3) in its correct installation position.
6 TORQUE the studs (2) to between 0.060 and 0.055 m.daN (5.31 and 4.87 lbf.in )
. NOTE: When you tighten the studs you will hear a click. This is a sign that you have used the correct procedure to tighten the studs. This click is not a sign that the correct torque value is applied. When the studs are tightened, make sure that the correct torque value is applied.
7 Install the partition panel (5) (Ref. AMM TASK 25-54-12-400-001) or (Ref. AMM TASK 25-55-12-400-001). Subtask 25-50-00-865-128-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-50-00-410-060-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | SEMI AUTO CLS-FWD | 3MY | E08 |
| 2000VU | SEMI AUTO CLS-FWD | 2MY | E06 |
| 2001VU | SEMI AUTO CLS-AFT | 103MY | D08 |
| 2001VU | SEMI AUTO CLS-AFT | 102MY | D06 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) Set the light switch to off.
(4) Close the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
(6) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
Subtask 25-50-00-410-060-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) Set the light switch to off.
(4) Close the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
(6) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Set the light switch to off.
(3) Close the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the access platform(s).
(5) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Set the light switch to off.
(3) Close the forward and/or aft cargo-compartment doors (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the access platform(s).
(5) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).