Fasteners Missing from the Lining Panels of the Aft Cargo Compartment
TASK 25-55-11-300-001-A
Fasteners Missing from the Lining Panels of the Aft Cargo Compartment
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 25-55-11-010-055-A
Subtask 25-55-11-210-051-A
Subtask 25-55-11-865-077-A
[Rev.10 from 2021]
2026.04.01 03:55:57 UTC
Fasteners Missing from the Lining Panels of the Aft Cargo Compartment
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
USE ONLY THE SPECIFIED MATERIALS AND OBEY THE INSTRUCTIONS FROM THE MATERIAL MANUFACTURERS. OTHER MATERIALS CAN CAUSE DAMAGE TO THE SURFACE PROTECTION OF THE COMPONENTS AND THE RELATED AREA.
ZONE: 150
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | Torque wrench: range to between 0.060 and 0.055 m.daN (5.31 and 4.87 lbf.in ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RAB9) | Adhesive Film Tape-- Aluminium Foil - |
| (Material No.05TAB1) | Adhesive Tape-- Glass Cloth - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-50-00-200-002-A | Visual Check of Cargo Compartment Decompression, Lining, Floor Panels and Pressure Compensation Valve (as far as Visible, if ACT(s) or Sliding Carpet System Installed) |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 25-50-00-00 | CARGO COMPARTMENTS - DESCRIPTION AND OPERATION |
| TASK 25-50-00-00-01 | CARGO COMPARTMENTS - DESCRIPTION AND OPERATION |
| TASK 25-50-00-00-02 | CARGO COMPARTMENTS - DESCRIPTION AND OPERATION |
Subtask 25-55-11-010-055-A
A. Get Access
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the aft cargo-compartment door.
(4) Set the light switch to on.
(5) If the MECHANISED BULK CARGO LOADING SYSTEM is installed:
(a) Remove the side guides (Ref. AMM D/O 25-52-15-00).
Subtask 25-55-11-865-076-A (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 2M (6 FT) in position at the opening of the aft cargo-compartment door.
(4) Set the light switch to on.
(5) If the MECHANISED BULK CARGO LOADING SYSTEM is installed:
(a) Remove the side guides (Ref. AMM D/O 25-52-15-00).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | SEMI AUTO CLS-AFT | 103MY | D08 |
| 2001VU | SEMI AUTO CLS-AFT | 102MY | D06 |
Subtask 25-55-11-210-051-A
A. Inspection
(1) Do an inspection of the lining panels of the aft cargo-compartment for missing fasteners (Ref. AMM TASK 25-50-00-200-002).
(2) If necessary, replace the missing fasteners.
(3) Refer to (Ref. AMM D/O 25-50-00-00) for the applicable panel type (rapid decompression panels or collapsing lining panels).
Subtask 25-55-11-350-050-C ** ON A/C NOT FOR ALL (1) Do an inspection of the lining panels of the aft cargo-compartment for missing fasteners (Ref. AMM TASK 25-50-00-200-002).
(2) If necessary, replace the missing fasteners.
(3) Refer to (Ref. AMM D/O 25-50-00-00) for the applicable panel type (rapid decompression panels or collapsing lining panels).
B. Repair of a Lining Panel with a Missing Fastener (Rapid Decompression Safety-System - Rapid Decompression Panel)
(a) TORQUE the stud to between 0.060 and 0.055 m.daN (5.31 and 4.87 lbf.in )
.
(3) Make sure that you obey all these conditions for permitted/not permitted missing fasteners:
(a) Missing fasteners are permitted if:
(4) Repair the missing fastener as follows:
(a) Seal the hole on the lining panel where the fastener is missing with the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) or the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) .
(b) Make sure that the tape length does not extend the adjacent structure, adjacent fasteners or the adjacent panel.
Subtask 25-55-11-350-050-D ** ON A/C NOT FOR ALL WARNING:
USE GOGGLES AND PROTECTIVE CLOTHING WHEN YOU REMOVE, INSTALL OR TORQUE THE FASTENER.
IF PARTS OF THE FASTENER RELEASE SUDDENLY, THERE IS A RISK OF INJURY.
CAUTION:
WHEN THE RELEASE FUNCTION OF THE BRACKET (SPRING-LOADED CATCH) WAS OPERATED, REPLACE THE FASTENER ASSEMBLY WITH THE SILVER METALLIC WASHERS.
DO NOT INSTALL FASTENER ASSEMBLIES WITH WHITE WASHERS TOGETHER WITH FASTENER ASSEMBLIES WITH SILVER METALLIC WASHERS ON THE SAME PANEL.
THIS CAN CAUSE MALFUNCTION OF THE RELATED PANEL.
(1) If a stud is missing, loosely install a new fastener assembly (stud, washer and lockwasher): (a) TORQUE the stud to between 0.060 and 0.055 m.daN (5.31 and 4.87 lbf.in )
. NOTE: When you tighten the studs you will hear a click. This is a sign that you used the correct procedure to tighten the studs. This click is not a sign that the correct torque value is applied. The applicable torque value must be between 0.055 and 0.060 m.daN in order to get 0.040 to 0.060 m.daN (measured on installed lining panel), because of to the compressible connection.
(2) If it is not possible to replace the missing fastener, do the temporary repair as follows. (3) Make sure that you obey all these conditions for permitted/not permitted missing fasteners:
(a) Missing fasteners are permitted if:
- Not more than one fastener is missing from each panel quadrant in a ceiling/sidewall/partition lining panel.
- Not more than one fastener is missing from each interface cutout in a ceiling/sidewall/partition lining panel.
- In a corner of a ceiling/sidewall/partition lining panel.
- In a clamp profile.
| Inspection Interval | Action |
|---|---|
| 0-100 flight hours (10 days) after the detection of the defect. | Do a visual inspection one time each week. |
| 101-500 flight hours (50 days) after the detection of the defect. | Do a visual inspection one time each day. |
| Maximum 500 flight hours (50 days) after the detection of the defect. | Install a new fastener assembly (stud, washer and lockwasher). |
(a) Seal the hole on the lining panel where the fastener is missing with the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) or the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) .
(b) Make sure that the tape length does not extend the adjacent structure, adjacent fasteners or the adjacent panel.
B. Repair of a Lining Panel with a Missing Fastener (Rapid Decompression Safety-System - Collapsing Lining Panel)
(a) TORQUE the stud to between 0.060 and 0.055 m.daN (5.31 and 4.87 lbf.in )
.
(3) Make sure that you obey all these conditions for permitted/not permitted missing fasteners:
(a) Missing fasteners are permitted if:
(4) Repair the missing fastener as follows:
5. Close-upWARNING:
USE GOGGLES AND PROTECTIVE CLOTHING WHEN YOU REMOVE, INSTALL OR TORQUE THE FASTENER.
IF PARTS OF THE FASTENER RELEASE SUDDENLY, THERE IS A RISK OF INJURY.
CAUTION:
WHEN THE RELEASE FUNCTION OF THE BRACKET (SPRING-LOADED CATCH) WAS OPERATED, REPLACE THE FASTENER ASSEMBLY WITH THE SILVER METALLIC WASHERS.
DO NOT INSTALL FASTENER ASSEMBLIES WITH WHITE WASHERS TOGETHER WITH FASTENER ASSEMBLIES WITH SILVER METALLIC WASHERS ON THE SAME PANEL.
THIS CAN CAUSE MALFUNCTION OF THE RELATED PANEL.
(1) If a stud is missing, loosely install a new fastener assembly (stud, washer and lockwasher): (a) TORQUE the stud to between 0.060 and 0.055 m.daN (5.31 and 4.87 lbf.in )
. NOTE: When you tighten the studs you will hear a click. This is a sign that you used the correct procedure to tighten the studs. This click is not a sign that the correct torque value is applied. The applicable torque value must be between 0.055 and 0.060 m.daN in order to get 0.040 to 0.060 m.daN (measured on installed lining panel), because of to the compressible connection.
(2) If it is not possible to replace the missing fastener, do the temporary repair as follows. (3) Make sure that you obey all these conditions for permitted/not permitted missing fasteners:
(a) Missing fasteners are permitted if:
- Not more than one fastener is missing from each sidewall lining panel.
NOTE: This condition is only applicable for aircraft that do not have a Cargo Loading System (CLS).
- Not more than one fastener is missing from each panel quadrant in a ceiling/partition lining panel.
- Not more than one fastener is missing from each interface cutout in a ceiling/partition lining panel.
- In a sidewall panel.
NOTE: This condition is only applicable for aircraft that have a Cargo Loading System (CLS).
- In a corner of a ceiling/partition/sidewall lining panel.
- In a clamp profile.
- In a triangle lining panel.
- In an adjacent ceiling lining panel.
| Inspection Interval | Action |
|---|---|
| 0-100 flight hours (10 days) after the detection of the defect. | Do a visual inspection one time each week. |
| 101-500 flight hours (50 days) after the detection of the defect. | Do a visual inspection one time each day. |
| Maximum 500 flight hours (50 days) after the detection of the defect. | Install a new fastener assembly (stud, washer and lockwasher). |
CAUTION:
MAKE SURE THAT THERE IS NO OVERLAP BETWEEN THE TAPE AND THE ADJACENT STRUCTURE, THE ADJACENT FASTENERS OR THE ADJACENT PANEL. AN OVERLAP CAN CAUSE MALFUNCTION OF THE COLLAPSING LINING PANELS.
(a) Seal the hole on the lining panel where the fastener is missing with the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) or the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) . Subtask 25-55-11-865-077-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-55-11-410-055-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | SEMI AUTO CLS-AFT | 103MY | D08 |
| 2001VU | SEMI AUTO CLS-AFT | 102MY | D06 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) If the MECHANISED BULK CARGO LOADING SYSTEM is installed:
(a) Install the side guides (Ref. AMM D/O 25-52-15-40).
(3) Set the light switch to off.
(4) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
(6) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) If the MECHANISED BULK CARGO LOADING SYSTEM is installed:
(a) Install the side guides (Ref. AMM D/O 25-52-15-40).
(3) Set the light switch to off.
(4) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(5) Remove the access platform(s).
(6) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
Missing Fastener Inspection