W DOC AIRBUS | AMM A320F

Installation of the DEU A/DEU B - Mount


TASK 23-73-48-400-001-A
Installation of the DEU A/DEU B - Mount


1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
STEPLADDER 0.5 M (1.6 FT)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 23-73-00-740-003-A
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the PTP
TASK 23-73-00-861-001-A
Energize the Cabin Intercommunication Data System (CIDS)
TASK 23-73-46-400-001-A
Installation of the Decoder/Encoder Unit A
TASK 23-73-47-400-001-A
Installation of the Decoder/Encoder Unit B
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-23-42-000-001-A
Removal of the Ceiling Panels - Forward Utility Area
TASK 25-23-42-000-002-A
Removal of the Ceiling Panels - Aft Utility Area
TASK 25-23-42-400-001-A
Installation of the Ceiling Panels - Forward Utility Area
TASK 25-23-42-400-002-A
Installation of the Ceiling Panels - Aft Utility Area
TASK 25-23-48-000-001-A
Removal of the Cove Light Panel
TASK 25-23-48-400-001-A
Installation of the Cove Light Panel
F Mount DEU A / DEU B ** ON A/C NOT FOR ALL
F Mount DEU A / DEU B ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 23-73-48-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that aircraft electrical circuits are energized
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the STEPLADDER 0.5 M (1.6 FT) is below the related access panel.
   (3) Make sure that the related cove light panel (Ref. AMM TASK 25-23-48-000-001), or the forward utility-area ceiling panel (Ref. AMM TASK 25-23-42-000-001), or the aft utility-area ceiling panel (Ref. AMM TASK 25-23-42-000-002) is removed.
Subtask 23-73-48-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DIR ESS/2157RHG02
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU A ESS/LINE 2155RHG05
49VUCOM/CIDS/DEU A ESS/LINE 1154RHG04
49VUCOM/CIDS/DEU B/ESS153RHG03
** ON A/C NOT FOR ALL
49VUCOM DIR ESS/2157RHG02
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R AFT168RHM14
121VUCOM NAV/CIDS/DEU A NORM/L AFT167RHM13
121VUCOM NAV/CIDS/DEU A NORM/R MID166RHM12
121VUCOM NAV/CIDS/DEU A NORM/L MID165RHM11
121VUCOM NAV/CIDS/DEU A NORM/R FWD164RHM10
121VUCOM NAV/CIDS/DEU A NORM/L FWD163RHM09
121VUCOM NAV/CIDS/DEU B/NORM162RHM08
121VUCOM NAV/CIDS/DIR NORM/2156RHM06
121VUCOM/CIDS/DEU A BAT/LINE 2145RHN14
121VUCOM/CIDS/DEU A BAT/LINE 1144RHN13
121VUCOM/CIDS/DEU B/BAT143RHN12
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R MID166RHM13
121VUCOM NAV/CIDS/DEU A NORM/L MID165RHM12
121VUCOM NAV/CIDS/DEU A NORM/R FWD164RHM11
121VUCOM NAV/CIDS/DEU A NORM/L FWD163RHM10
121VUCOM NAV/CIDS/DEU B/NORM162RHM09
121VUCOM NAV/CIDS/DIR NORM/2156RHM07
2001VUCIDS/ DEU A NORM AFT RH174RHC08
2001VUCIDS/ DEU A NORM AFT LH173RHC07
2001VUCIDS/ DEU A NORM MID 2 RH176RHC06
2001VUCIDS/ DEU A NORM MID 2 LH175RHC05
4. Procedure
Subtask 23-73-48-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the DEU A/DEU B-Mount
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Install the DEU mount (1) with the screws (3) and washers (4).
   (4) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (5) Make sure that all the electrical connections are clean and in the correct condition.
   (6) Connect the electrical connector to the DEU mount (1).
   (7) Remove the cover (5) from the DEU mount (1).
   (8) Set the coding switches to the same position as shown on the label.
   (9) Install the cover (5).
   (10) Install the related DEU A (Ref. AMM TASK 23-73-46-400-001) or DEU B (Ref. AMM TASK 23-73-47-400-001).
Subtask 23-73-48-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clips and tags and close these circuit breakers in this sequence:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUCIDS/ DEU A NORM MID 2 RH176RHC06
2001VUCIDS/ DEU A NORM MID 2 LH175RHC05
2001VUCIDS/ DEU A NORM AFT RH174RHC08
2001VUCIDS/ DEU A NORM AFT LH173RHC07
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R AFT168RHM14
121VUCOM NAV/CIDS/DEU A NORM/L AFT167RHM13
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R MID166RHM13
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R MID166RHM12
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/L MID165RHM12
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/L MID165RHM11
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R FWD164RHM11
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/R FWD164RHM10
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/L FWD163RHM10
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU A NORM/L FWD163RHM09
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM09
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DEU B/NORM162RHM08
** ON A/C NOT FOR ALL
49VUCOM/CIDS/DEU A ESS/LINE 2155RHG05
49VUCOM/CIDS/DEU A ESS/LINE 1154RHG04
49VUCOM/CIDS/DEU B/ESS153RHG03
** ON A/C NOT FOR ALL
121VUCOM/CIDS/DEU A BAT/LINE 2145RHN14
121VUCOM/CIDS/DEU A BAT/LINE 1144RHN13
121VUCOM/CIDS/DEU B/BAT143RHN12
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DIR NORM/2156RHM07
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DIR NORM/2156RHM06
49VUCOM/CIDS/DIR ESS/2157RHG02
** ON A/C NOT FOR ALL
49VUCOM DIR ESS/2157RHG02
Subtask 23-73-48-869-052-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make sure that the Cabin Intercommunication Data System (CIDS) is energized
(Ref. AMM TASK 23-73-00-861-001).
   (2) Do the BITE test of the Cabin Intercommunication Data System (CIDS) (Ref. AMM TASK 23-73-00-740-003).
5. Close-up
Subtask 23-73-48-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the related cove light panel (Ref. AMM TASK 25-23-48-400-001), or the forward utility-area ceiling panel (Ref. AMM TASK 25-23-42-400-001), or the aft utility-areaceiling panel (Ref. AMM TASK 25-23-42-400-002).
Subtask 23-73-48-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.03.31 23:18:55 UTC