21-63 COCKPIT AND CABIN TEMPERATURE CONTROL
- PB.201 COCKPIT AND CABIN TEMPERATURE CONTROL - FAULT ISOLATION PROCEDURES
-
21-63-00-810-801-A
[8]
Zone Controller Fault -
21-63-00-810-802-A
[8]
Cockpit Trim-Air Valve Fault -
21-63-00-810-803-A
[8]
FWD Cabin Trim-Air Valve Fault -
21-63-00-810-804-A
[8]
AFT Cabin Trim-Air Valve Fault -
21-63-00-810-805-A
[8]
Trim-Air Pressure Regulating Valve Fault -
21-63-00-810-806-A
[8]
Cockpit Temperature Sensor Fault -
21-63-00-810-807-A
[8]
FWD Cabin Temperature Sensor Fault -
21-63-00-810-808-A
[8]
AFT Cabin Temperature Sensor Fault -
21-63-00-810-809-A
[8]
Cockpit Duct Temperature Sensor Fault -
21-63-00-810-810-A
[8]
FWD Cabin Duct Temperature Sensor Fault -
21-63-00-810-811-A
[8]
AFT Cabin Duct Temperature Sensor Fault -
21-63-00-810-815-A
[8]
Mixer Unit L/H (Cockpit) Temperature Sensor Fault -
21-63-00-810-816-A
[8]
Mixer Unit R/H (Cabin) Temperature Sensor Fault -
21-63-00-810-817-A
[8]
Cockpit Temperature Selector Fault -
21-63-00-810-818-A
[8]
FWD Cabin Temperature Selector Fault -
21-63-00-810-819-A
[8]
AFT Cabin Temperature Selector Fault -
21-63-00-810-820-A
[8]
ZC receives no Data from the ADIRS -
21-63-00-810-821-A
[8]
Zone Temperature Control Problems in all Zones -
21-63-00-810-822-A
[8]
Zone Temperature Control Problems in one Zone -
21-63-00-810-823-A
[8]
Cockpit Duct Overheat Detection -
21-63-00-810-824-A
[8]
FWD Cabin Duct Overheat Detection -
21-63-00-810-825-A
[8]
AFT Cabin Duct Overheat Detection -
21-63-00-810-827-A
[8]
Zone Cont Electrical Component with Short Circuit (Primary/Secondary Channels) -
21-63-00-810-828-A
[8]
DMU receives no Data from the ZC -
21-63-00-810-829-A
[8]
ZC receives no Data from the CFDS -
21-63-00-810-830-A
[8]
ECB receives no Data from the ECS -
21-63-00-810-831-A
[8]
Zone Controller Pin Program Mismatch -
21-63-00-810-833-A
[8]
Low Bleed Air from Engine 1 -
21-63-00-810-834-A
[8]
Low Bleed Air from Engine 2 -
21-63-00-810-835-A
[8]
Mixer-Unit Temperature Sensors Fault -
21-63-00-810-843-A
[8]
Actual Zone Temperatures are above Selected Zone Temperatures (In Flight) -
21-63-00-810-844-A
[8]
Zone Cont Electrical Component with Short Circuit (Primary Channel) -
21-63-00-810-845-A
[8]
Zone Cont Electrical Component with Short Circuit (Secondary Channel) -
21-63-00-810-846-A
[8]
Actual Zone Temperatures are above Selected Zone Temperatures (Cockpit) -
21-63-00-810-847-A
[8]
Actual Zone Temperatures are above Selected Zone Temperatures (Cabin) -
21-63-00-810-848-A
[8]
Failure Not Clearly Identified - Zone Controller Fault -
21-63-00-810-849-A
[8]
Trim-Air Pressure Regulating Valve or Pressure Switch Fault -
21-63-00-810-850-A
[8]
Pack 1 Trim Air Check Valve Fault -
21-63-00-810-851-A
[8]
Pack 2 Trim Air Check Valve Fault -
21-63-00-810-855-A
[8]
Cockpit Temperature uncontrollable or too low with TAV AMBER XX -
21-63-00-810-856-A
[8]
FWD Cabin Temperature uncontrollable or too low with TAV AMBER XX -
21-63-00-810-857-A
[8]
AFT Cabin Temperature uncontrollable or too low with TAV AMBER XX -
21-63-00-810-858-A
[8]
ECS receives no Data from CIDS -
21-63-00-810-859-A
[8]
CIDS receives no Data from the ZC
-
21-63-00-810-801-A
[8]
- PB.301 COCKPIT AND CABIN TEMPERATURE CONTROL - TASK SUPPORTING DATA