W DOC AIRBUS | TSM A320F

AFT Cabin Temperature uncontrollable or too low with TAV AMBER XX


TASK 21-63-00-810-857-A
AFT Cabin Temperature uncontrollable or too low with TAV AMBER XX


1. Possible Causes
  • TRIM VALVE AFT CAB [13HK]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
ASM 216302
ASM 216303
AMM 21-63-51-000-001
Removal of the Trim Air Valve
AMM 21-63-51-400-001
Installation of the Trim Air Valve
3. Fault Confirmation
Subtask 21-63-00-710-143-A ** ON A/C NOT FOR ALL
A. Confirmation of the Fault
   (1) Do the operational test of the cockpit and cabin temperature-control system AMM 21-63-00-710-004.
4. Fault Isolation
Subtask 21-63-00-810-151-A ** ON A/C NOT FOR ALL
A. If on the ECAM COND page the AFT trim air valve position indication shows amber XX and/or the Aft cabin temperature is uncontrollable or too low (in flight):
   (1) If the fault continues:
     (a) This wiring check is only applicable for Trim Air Valves previous to P/N 1320A0000-01 or 963B0000-01 or 750B0000-01.
  • do a check and repair the wiring ASM 216303 from:
  • the TRIM VALVE AFT CABIN (13HK) to the Zone Controller (8HK) and,
  • the TRIM VALVE AFT CABIN (13HK) to ground.
     (b) This wiring check is only applicable for Trim Air Valves P/N 1320A0000-01 or 963B0000-01 or 750B0000-01 and subsequent.
  • do a check and repair the wiring ASM 216303 between:
  • TRIM VALVE AFT CABIN (13HK) connector A/U and ZC (8HK) connector AB/15A,
  • TRIM VALVE AFT CABIN (13HK) connector A/J and ZC (8HK) connector AB/15C,
  • TRIM VALVE AFT CABIN (13HK) connector A/K and ZC (8HK) connector AB/15D,
  • TRIM VALVE AFT CABIN (13HK) connector A/L and ZC (8HK) connector AB/15E,
  • TRIM VALVE AFT CABIN (13HK) connector A/C and ZC (8HK) connector AB/5C,
  • TRIM VALVE AFT CABIN (13HK) connector A/E and ZC (8HK) connector AB/5B,
  • the TRIM VALVE AFT CABIN (13HK) to ground.
Subtask 21-63-00-810-151-B ** ON A/C NOT FOR ALL
A. If on the ECAM COND page the AFT trim air valve position indication shows amber XX and/or the Aft cabin temperature is uncontrollable or too low (in flight):
   (1) If the fault continues:
  • do a check and repair the wiring ASM 216302 from:
  • the TRIM AIR VALVE AFT CABIN (13HK) to the ACSC2 (57HH) and,
  • the TRIM AIR VALVE AFT CABIN (13HK) to ground.
Subtask 21-63-00-710-144-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.