W DOC AIRBUS | TSM A320F

Zone Controller Fault


TASK 21-63-00-810-801-A
Zone Controller Fault


1. Possible Causes
  • ZONE CONTROLLER [8HK]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 21-63-00-810-827-A
Zone Cont Electrical Component with Short Circuit (Primary/Secondary Channels)
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
ASM 216301
ASM 216302
AMM 21-63-34-000-001
Removal of the Zone Controller
AMM 21-63-34-400-001
Installation of the Zone Controller
3. Fault Confirmation
Subtask 21-63-00-710-050-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
NOTE: If a fault is detected, the ZC gives a fault code for shop maintenance in addition to the related CFDS message(s). For detailed information see the applicable Page Block 301.
4. Fault Isolation
Subtask 21-63-00-810-051-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ZONE CONT:
   (1) If the fault continues:
  • do a check and repair the wiring if necessary between:
    ZC (8HK) connector AC/6 and CB (1HK),
    ZC (8HK) connector AC/4 and GND,
    ZC (8HK) connector AC/5 and CB (2HK),
    ZC (8HK) connector AC/1 and GND,
    ZC (8HK) connector AC/11 and GND,
    ZC (8HK) connector AB/K8 and GND,
    ZC (8HK) connector AB/J13 and CB (3HK) ASM 216301.
   (2) If the fault continues:
  • do a check and repair the wiring if necessary of the signal:
    ARINC 429 XTR INT (P) from the ZC (8HK) to the PC 1 (7HH) and the PC 2 (27HH),
    ARINC 429 XTR INT (S) from the ZC (8HK) to the PC 1 (7HH) and the PC 2 (27HH),
    ARINC 429 RCV INT (S) from the ZC (8HK) to the PC 1 (7HH),
    ARINC 429 RCV INT (P) from the ZC (8HK) to the PC 2 (27HH) ASM 216302.
   (3) If the fault continues:
Subtask 21-63-00-810-076-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message NO 28V ON ZONE MAIN:
  • do a check and repair the wiring between:
    ZC (8HK) connector AC/10 and CB (3HK),
    ZC (8HK) connector AC/8 and GND ASM 216301.
Subtask 21-63-00-810-077-A ** ON A/C NOT FOR ALL
C. If the test gives the maintenance message NO 28V ON ZONE SECD:
  • do a check and repair the wiring between:
    ZC (8HK) connector AC/9 and CB (4HK),
    ZC (8HK) connector AC/7 and GND ASM 216301.
Subtask 21-63-00-710-051-A ** ON A/C NOT FOR ALL
D. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 21-63-00-860-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:25:00 UTC