Zone Controller Fault
TASK 21-63-00-810-801-A
Zone Controller Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-63-00-710-050-A ** ON A/C NOT FOR ALL
Subtask 21-63-00-810-051-A ** ON A/C NOT FOR ALL
Subtask 21-63-00-860-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:00 UTC
Zone Controller Fault
1. Possible Causes
- ZONE CONTROLLER [8HK]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 21-63-00-810-827-A | Zone Cont Electrical Component with Short Circuit (Primary/Secondary Channels) |
| AMM 21-63-00-710-004 | Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU |
| ASM 216301 | |
| ASM 216302 | |
| AMM 21-63-34-000-001 | Removal of the Zone Controller |
| AMM 21-63-34-400-001 | Installation of the Zone Controller |
Subtask 21-63-00-710-050-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
4. Fault IsolationNOTE: If a fault is detected, the ZC gives a fault code for shop maintenance in addition to the related CFDS message(s). For detailed information see the applicable Page Block 301.
Subtask 21-63-00-810-051-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ZONE CONT:
Subtask 21-63-00-810-076-A ** ON A/C NOT FOR ALL - replace the ZONE CONTROLLER [8HK] AMM 21-63-34-000-001 and AMM 21-63-34-400-001.
- do a check and repair the wiring if necessary between:
ZC (8HK) connector AC/6 and CB (1HK),
ZC (8HK) connector AC/4 and GND,
ZC (8HK) connector AC/5 and CB (2HK),
ZC (8HK) connector AC/1 and GND,
ZC (8HK) connector AC/11 and GND,
ZC (8HK) connector AB/K8 and GND,
ZC (8HK) connector AB/J13 and CB (3HK) ASM 216301.
- do a check and repair the wiring if necessary of the signal:
ARINC 429 XTR INT (P) from the ZC (8HK) to the PC 1 (7HH) and the PC 2 (27HH),
ARINC 429 XTR INT (S) from the ZC (8HK) to the PC 1 (7HH) and the PC 2 (27HH),
ARINC 429 RCV INT (S) from the ZC (8HK) to the PC 1 (7HH),
ARINC 429 RCV INT (P) from the ZC (8HK) to the PC 2 (27HH) ASM 216302.
- do the trouble shooting procedures for the zone cont electrical component with short circuit (Ref. TSM TASK 21-63-00-810-827).
B. If the test gives the maintenance message NO 28V ON ZONE MAIN:
Subtask 21-63-00-810-077-A ** ON A/C NOT FOR ALL - do a check and repair the wiring between:
ZC (8HK) connector AC/10 and CB (3HK),
ZC (8HK) connector AC/8 and GND ASM 216301.
C. If the test gives the maintenance message NO 28V ON ZONE SECD:
Subtask 21-63-00-710-051-A ** ON A/C NOT FOR ALL - do a check and repair the wiring between:
ZC (8HK) connector AC/9 and CB (4HK),
ZC (8HK) connector AC/7 and GND ASM 216301.
D. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-63-00-860-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.