Zone Cont Electrical Component with Short Circuit (Secondary Channel)
TASK 21-63-00-810-845-A
Zone Cont Electrical Component with Short Circuit (Secondary Channel)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-63-00-710-131-A ** ON A/C NOT FOR ALL
Subtask 21-63-00-810-136-B ** ON A/C NOT FOR ALL
Subtask 21-63-00-860-081-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:04 UTC
Zone Cont Electrical Component with Short Circuit (Secondary Channel)
1. Possible Causes
- ZONE CONTROLLER [8HK]
- TEMP SENSOR RH MIXER [25HK]
- TEMP SENSOR CKPT DUCT [15HK]
- TEMP SENSOR FWD CAB DUCT [16HK]
- TEMP SENSOR AFT CAB DUCT [17HK]
- SENSOR-TEMPERATURE, COCKPIT [21HK]
- TEMP SENSOR FWD CAB [22HK]
- TEMP SENSOR AFT CAB [23HK]
- TEMP SENSOR LH MIXER [24HK]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-63-00-710-004 | Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU |
| ASM 216303 | |
| AMM 21-63-15-000-001 | Removal of the Duct Temperature Sensors |
| AMM 21-63-15-400-001 | Installation of the Duct Temperature Sensors |
| AMM 21-63-16-000-001 | Removal of the Mixer Temperature Sensor |
| AMM 21-63-16-400-001 | Installation of the Mixer Temperature Sensor |
| AMM 21-63-17-000-001 | Removal of the Temperature Sensors |
| AMM 21-63-17-400-001 | Installation of the Temperature Sensors |
| AMM 21-63-34-000-001 | Removal of the Zone Controller |
| AMM 21-63-34-400-001 | Installation of the Zone Controller |
Subtask 21-63-00-710-131-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU.
AMM 21-63-00-710-004.
4. Fault IsolationAMM 21-63-00-710-004.
NOTE: If a fault is detected, the ZC gives a fault code for shop maintenance in addition to the related CFDS message(s).
For detailed information see the applicable Page Block 301.
For detailed information see the applicable Page Block 301.
Subtask 21-63-00-810-136-B ** ON A/C NOT FOR ALL
A. If the ECAM lower DU gives the warning ZONE CONT or the test gives the maintenance message ZONE CONT OR SENSOR SUPPLY SHORT:
(a) For wiring and pin identification used in this procedure:
(b) For disconnection/connection of electrical connectors refer to the applicable work step in para. 4. A. (2).
(2) If the fault continues:
AMM 21-63-16-000-001 and,
AMM 21-63-16-400-001.
(b) If the voltage is not between 4.8 VDC and 5.2 VDC:
(b) If there is a short circuit repair the related wiring between:
* connector (15HKA) pin C and ZC connector (8HKAA) pin 9K,
* connector (15HKA) pin D and ZC connector (8HKAA) pin 9J.
(b) If there is a short circuit repair the related wiring between:
* connector (16HKA) pin C and ZC connector (8HKAA) pin 9H,
* connector (16HKA) pin D and ZC connector (8HKAA) pin 9G.
(b) If there is a short circuit repair the related wiring between:
* connector (17HKA) pin C and ZC connector (8HKAA) pin 10K,
* connector (17HKA) pin D and ZC connector (8HKAA) pin 10J.
(b) If there is a short circuit repair the related wiring between:
* connector (21HKA) pin D and ZC connector (8HKAA) pin 7K,
* connector (21HKA) pin E and ZC connector (8HKAA) pin 7J.
(b) If there is a short circuit repair the related wiring between:
* connector (22HKA) pin D and ZC connector (8HKAA) pin 7H,
* connector (22HKA) pin E and ZC connector (8HKAA) pin 7G.
(b) If there is a short circuit repair the related wiring between:
* connector (23HKA) pin D and ZC connector (8HKAA) pin 8K,
* connector (23HKA) pin E and ZC connector (8HKAA) pin 8J.
(b) If there is a short circuit repair the related wiring between:
* connector (24HKA) pin C and ZC connector (8HKAA) pin 8H,
* connector (24HKA) pin D and ZC connector (8HKAA( pin 8G.
(b) If there is a short circuit repair the related wiring between:
* connector (25HKA) pin C and ZC connector (8HKAA) pin 10H,
* connector (25HKA) pin D and ZC connector (8HKAA) pin 10G.
Subtask 21-63-00-710-132-A ** ON A/C NOT FOR ALL - replace the ZONE CONTROLLER [8HK] .
AMM 21-63-34-000-001 and,
AMM 21-63-34-400-001.
(a) For wiring and pin identification used in this procedure:
(b) For disconnection/connection of electrical connectors refer to the applicable work step in para. 4. A. (2).
(2) If the fault continues:
- disconnect the electrical connector (25HKA) from the TEMP SENSOR RH MIXER [25HK] ,
- make sure that the electrical connector is clean and in the correct condition,
- do a check for 5 VDC at the electrical connector (25HKA) between pins C and D (5 VDC from zone controller secondary channel).
AMM 21-63-16-000-001 and,
AMM 21-63-16-400-001.
(b) If the voltage is not between 4.8 VDC and 5.2 VDC:
- disconnect the electrical connector (15HKA) from the TEMP SENSOR CKPT DUCT [15HK] .
- make sure that the electrical connector is clean and in the correct condition,
- do a check for 5 VDC again.
- replace the TEMP SENSOR CKPT DUCT [15HK] .
AMM 21-63-15-000-001 and,
AMM 21-63-15-400-001. - connect the electrical connector (15HKA).
- repeat para. 4.A.(2) (b) for:
- connector (16HKA) and the TEMP SENSOR FWD CAB DUCT [16HK] .
AMM 21-63-15-000-001 and,
AMM 21-63-15-400-001. - connector (17HKA) and the TEMP SENSOR AFT CAB DUCT [17HK] .
AMM 21-63-15-000-001 and,
AMM 21-63-15-400-001. - connector (21HKA) and the SENSOR-TEMPERATURE, COCKPIT [21HK] .
AMM 21-63-17-000-001 and,
AMM 21-63-17-400-001. - connector (22HKA) and the TEMP SENSOR FWD CAB [22HK] .
AMM 21-63-17-000-001 and,
AMM 21-63-17-400-001. - connector (23HKA) and the TEMP SENSOR AFT CAB [23HK] .
AMM 21-63-17-000-001 and,
AMM 21-63-17-400-001. - connector (24HKA) and the TEMP SENSOR LH MIXER [24HK] .
AMM 21-63-16-000-001 and,
AMM 21-63-16-400-001. - connect the electrical connector (25HKA).
- on the circuit breaker panel 122VU open the CB's 1HK (V17), 2HK (V18), 3HK (V19) and 4HK (V20),
- remove the ZONE CONTROLLER [8HK] .
AMM 21-63-34-000-001. - disconnect the electrical connector (15HKA) from the TEMP SENSOR CKPT DUCT [15HK] ,
- at the electrical connector (15HKA) do a check for a short circuit between:
* pins C and D and,
* GND and pins C and D.
(b) If there is a short circuit repair the related wiring between:
* connector (15HKA) pin C and ZC connector (8HKAA) pin 9K,
* connector (15HKA) pin D and ZC connector (8HKAA) pin 9J.
- connect the electrical connector (15HKA).
- disconnect the electrical connector (16HKA) from the TEMP SENSOR FWD CAB DUCT [16HK] .
- at the electrical connector (16HKA) do a check for a short circuit between:
* pins C and D and,
* GND and pins C and D.
(b) If there is a short circuit repair the related wiring between:
* connector (16HKA) pin C and ZC connector (8HKAA) pin 9H,
* connector (16HKA) pin D and ZC connector (8HKAA) pin 9G.
- connect the electrical connector (16HKA).
- disconnect the electrical connector (17HKA) from the TEMP SENSOR AFT CAB DUCT [17HK] .
- at the electrical connector (17HKA) do a check for a short circuit between:
pins C and D and,
* GND and pins C and D.
(b) If there is a short circuit repair the related wiring between:
* connector (17HKA) pin C and ZC connector (8HKAA) pin 10K,
* connector (17HKA) pin D and ZC connector (8HKAA) pin 10J.
- connect the electrical connector (17HKA).
- disconnect the electrical connector (21HKA) from the SENSOR-TEMPERATURE, COCKPIT [21HK] .
- at the electrical connector (21HKA) do a check for a short circuit between:
* pins D and E and,
* GND and pins D and E.
(b) If there is a short circuit repair the related wiring between:
* connector (21HKA) pin D and ZC connector (8HKAA) pin 7K,
* connector (21HKA) pin E and ZC connector (8HKAA) pin 7J.
- connect the electrical connector (21HKA).
- disconnect the electrical connector (22HKA) from the TEMP SENSOR FWD CAB [22HK] .
- at the electrical connector (22HKA) do a check for a short circuit between:
* pins D and E and,
* GND and pins D and E.
(b) If there is a short circuit repair the related wiring between:
* connector (22HKA) pin D and ZC connector (8HKAA) pin 7H,
* connector (22HKA) pin E and ZC connector (8HKAA) pin 7G.
- connect the electrical connector (22HKA).
- disconnect the electrical connector (23HKA) from the TEMP SENSOR AFT CAB [23HK] .
- at the electrical connector (23HKA) do a check for a short circuit between:
* pins D and E and,
* GND and pins D and E.
(b) If there is a short circuit repair the related wiring between:
* connector (23HKA) pin D and ZC connector (8HKAA) pin 8K,
* connector (23HKA) pin E and ZC connector (8HKAA) pin 8J.
- connect the electrical connector (23HKA).
- disconnect the electrical connector (24HKA) from the TEMP SENSOR LH MIXER [24HK] .
- at the electrical connector do a check for a short circuit between:
* pins C and D and,
* GND and pins C and D.
(b) If there is a short circuit repair the related wiring between:
* connector (24HKA) pin C and ZC connector (8HKAA) pin 8H,
* connector (24HKA) pin D and ZC connector (8HKAA( pin 8G.
- connect the electrical connector (24HKA).
- disconnect the electrical connector (25HKA) from the TEMP SENSOR RH MIXER [25HK] .
- at the electrical connector (25HKA) do a check for a short circuit between:
* pins C and D and,
* GND and pins C and D.
(b) If there is a short circuit repair the related wiring between:
* connector (25HKA) pin C and ZC connector (8HKAA) pin 10H,
* connector (25HKA) pin D and ZC connector (8HKAA) pin 10G.
- connect the electrical connector (25HKA).
- install the ZONE CONTROLLER [8HK] .
AMM 21-63-34-000-001. - on the circuit breaker panel 122VU close the CB's 1HK (V17), 2HK (V18), 3HK (V19) and 4HK (V20).
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-63-00-860-081-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.